Catalog excerpts

SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Monitor AMI Turbitrack Data sheet no. DenA2541X200 Nephelometric system for the automatic and continuous measurement of low level turbidity in pure water with up to 10 bar sample pressure. Measurement range: 0.000 - 100.0 FNU/NTU Automatic range switching. High precision nephelometer complying with ISO 7027 (EN 27027, DIN 38404) Precision: ± 0.001 FNU/NTU or 1% of reading. Response time: typically T90 < 15 sec (after sample entry at 10 l/h) Manual verification with high precision secondary standards. Pressure tight sample system up to 10 bar avoids outgassing of sample. Transmitter, turbidity sensor, flow cell, flow controller and sensor mounted on panel for immediate use. Transmitter with large backlit graphic display for the reading of measuring value, flow and operating status. Full text menu driven user interface. Storage of calibration history. Two signal outputs for measuring values or as control outputs. Potential-free alarm contact as summary alarm indication for programmable alarm values and for instrument faults. Two potential-free contacts programmable as limit switch or PID-control. Input for potential-free contact with programmable function. Factory tested and calibrated with formazine standards, ready for use. Automatic purging of optical measurement chamber in programmable intervals. Monitor AMI Turbitrack DC Option: [ ] 3 current signal output (0/4 – 20mA) [ ] Profibus DP & Modbus RTU interface (RS-485) [ ] HART interface 09/2022 Subject to change without notice
Open the catalog to page 1
SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Turbidimeter System Monitor AMI Turbitrack Data sheet no. DenA2541X200 Electrical Connection Scheme Turbidimeter with flow controller. Measurement range: 0.000 - 100.0 FNU/NTU with automatic range switching Precision: 0.001 FNU/NTU or 1% of reading with automatic purging of optical chamber in programmable intervals. Transmitter Specifications and Functions Electronics case: Cast aluminum Protection degree: IP 66 / NEMA 4X Display: backlit LCD, 75 x 45 mm Electrical connectors: screw...
Open the catalog to page 2All Swan Analytical Instruments catalogs and technical brochures
-
Swansensor pH/Redox AY
1 Pages
-
Monitor AMI Turbitrace
2 Pages
-
AMI INSPECTOR
2 Pages
-
Swansensor PHARMACON
1 Pages
-
Monitor AMI LineTOC
2 Pages
-
Monitor AMI Turbiwell 7027
2 Pages
-
Monitor AMI Codes-II O3
2 Pages
-
Monitor AMI Oxytrace QED
2 Pages
-
Monitor AMI Rescon
2 Pages
-
Redox Calibration Solution
9 Pages