Monitor AMI Turbiwell 7027
2Pages

{{requestButtons}}

Catalog excerpts

Monitor AMI Turbiwell 7027 - 1

SWAN Analytische Instrumente AG CH-8340 Hinwil, Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Monitor AMI Turbiwell Data sheet no. DenA2541X600X Nephelometric system based on ISO 7027 for the automatic and continuous measurement of turbidity in potable water, surface water and effluent. Monitor AMI Turbiwell 7027  Non-contact turbidimeter: System optics is not in direct contact with sample, no fouling on optical surfaces.  Measuring range: 0.000 - 200.0 FNU/NTU Automatic range switching.  Precision: ± (0.003 FNU + 1 % of reading)  Complete system including measurement control electronics, sample chamber and turbidimeter  Manual or automated draining of the sample chamber.  Easy user menus in English, German, French, Spanish, Italian and Russian. Simple programming of all parameters by keypad.  Electronic record of major process events and calibration data.  Real-time clock for time stamp in data logs and for automated functions.  Data logger for 1’500 data records stored at selectable intervals.  Big back-lit LCD display for the reading of all measured values and status information simultaneously.  Measurement values are available as analog output signals.  Potential-free alarm contact as summary alarm indication for programmable alarm values and for instrument faults.  Input for potential-free contact to freeze the measuring value or to interrupt control in automated installations (hold function or remote-off).  Factory tested, ready for installation and operation. Accessories:  Turbidity verification kits (dry verification) Order no. Monitor AMI Turbiwell with manual drain valve and optional sample degasser Optional:  Communication interfaces  Sample degasser to avoid the formation of interfering bubbles in the samples  SS deltaT flow meter A–25.411.600.1 Monitor AMI Turbiwell 7027 Auto-drain AC Monitor AMI Turbiwell 7027 Auto-drain DC Option: [ ] HART interface [ ] Sample degasser [ ] 3 current signal output (0/4 – 20mA) [ ] Profibus DP & Modbus RTU interface (RS-485) 09/2022 Subject to change without no

Open the catalog to page 1
Monitor AMI Turbiwell 7027 - 2

SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Turbidimeter System Monitor AMI Turbiwell Data sheet no. DenA2541X600X Electrical Connection Scheme Nephelometer according to ISO 7027 Measuring range: 0.000-200.0 FNU/NTU Precision: ± (0.003 FNU + 1 % of reading) Accuracy (based on Formazine): Range 0-40 FNU: ± (0.01 FNU + 2 % of reading) Range > 40 FNU: ± 5 % of reading Two-part turbidimeter body made of PETP with drain valve. Heated optics to avoid condensation. Easy cleaning of sample compartment. Factory calibrated with...

Open the catalog to page 2

All Swan Analytical Instruments catalogs and technical brochures