Digestive Surgery Product Catalo a ~TI—I T^-ipIo-science divt^ion

Open the catalog to page 1
SWING-CONCEPT - 3

ADVANTAGES - Light porous structure to favour quick tissue ingrowth and colonization1, 2, 5 - Semi-rigid for optimal abdominal fit - Good shape memory for perfect use via laparoscopic or open surgery - Multidirectional mechanical properties Weight : 80 g/m2 - Thickness : 0,56 mm Mean bursting strength : ≥ 500 kPa* Pore size : 0,7 x 0,7 mm - Porosity : 48 % Mean Tensile strength (Warp/Weft) : 129/514 N Mean Elongation (Warp/Weft) : 118/77 % Weight : 55 g/m2 - Thickness : 0,48 mm Mean bursting strength. : ≥ 500 kPa* Pore size : 1,53 x 1,30 mm - Porosity : 62 % Mean Tensile strength...

Open the catalog to page 3
SWING-CONCEPT - 4

Weight : 113 g/m2 - Thickness : 0,54 mm Mean bursting strength : ≥ 500 kPa* Pore size : 1,58 x 1,20 mm - Porosity : 49 % Mean Tensile strength (Warp/Weft) : 284/562 N Mean Elongation (Warp/Weft) : 59/54 % Weight : 113 g/m2 - Thickness : 0,54 mm Mean bursting strength : ≥ 500 kPa* Pore size : 1,58 x 1,20 mm - Porosity : 49 % Mean Tensile strength (Warp/Weft) : 284/562 N Mean Elongation (Warp/Weft) : 59/54 % *Max. intra abdominal pressure 24 kPa *Max. intra abdominal pressure 24 kPa *Max. intra abdominal pressure 24 kPa - Knitted structure - Sealed openwork rectangular mesh - Polyester (PET)...

Open the catalog to page 4
SWING-CONCEPT - 5

A D V A N TA G E S - Porous structure to favour fast tissue ingrowth and colonization1, 2, 5 - Semi-rigid for optimal abdominal fit - Shape memory for use for laparoscopic or open surgery - Elasticity and excellent multidirectional mechanical properties SM2 1520 S VENTRAL HERNIA REPAIR Non-exhaustive reference list

Open the catalog to page 5
SWING-CONCEPT - 6

ADVANTAGES - Porous structure to favour fast tissue ingrowth and colonization1, 2, 5 - Semi-rigid for optimal abdominal fit - Shape memory for use via laparoscopic or open surgery - Elasticity and excellent multidirectional mechanical properties - Impregnated with polyurethane (PUR) SM3+ INDICATIONS Abdominal wall reinforcement - ventral - inguinal - femoral hernias for laparoscopic or open surgery VENTRAL HERNIA REPAIR *Max. intra abdominal pressure 24 kPa Non-exhaustive reference list - Polyester (PET) multifilament Sm3 Weight : 120 g/m2 - Thickness : 1,14 mm Mean bursting strength : 481...

Open the catalog to page 6
SWING-CONCEPT - 7

ADVANTAGES - Self gripping prosthesis thanks to atraumatic “grips” on both sides3, 4 - Easy repositioning during surgery3, 4 - Porous structure to favour fast tissue ingrowth and colonization1, 2, 5 - Shape memory for perfect use for laparoscopic or open surgery - Elasticity and excellent multidirectional mechanical properties *Max. intra abdominal pressure 24 kPa Abdominal wall reinforcement - ventral - inguinal - femoral hernias via laparoscopic or open surgery - CO3A is preferably used via laparoscopic totally extraperitoneal approach (TEP) VENTRAL HERNIA REPAIR Mean values given as an...

Open the catalog to page 7
SWING-CONCEPT - 8

Electronic microscopy picture - PEU side. The PET mesh features a well-orientated continuous fibrocellular coating. Tissue ingrowth and neovascularization. The polyurethane side is covered with a film of macrophagic peritoneal cells. The PEU structure consists of thick fibrous cords, reminiscent of fibroblast cells. Histological view at 24 weeks (x4). Histological view - PEU side (10x1.25). The fibrous tissue is well organized, orientated and shows vascular islands surrounded by lymphocitic elements. - No local sepsis observed (seroma, infection…) - All meshes were found intact and well...

Open the catalog to page 8
SWING-CONCEPT - 9

ADVANTAGES IS180 : Wide range of sizes and designs covering all laparoscopic indications VENTRO-S : Anatomical designs with fixation skirt for open surgery DESCRIPTION - Composite structure - Polyester (polyethylene terephthalate PET) multifilament, coated on one side with a thin membrane of polyurethane (PUR) - Precut and entirely macro-perforated prosthesis Weight : 184 g/m2 - Thickness : 1,38 mm Mean bursting strength. : 289 kPa* Pore size : 2,58 x 1,63 mm Porosity (Visceral side/Parietal side) : 1,4 %/55 % Mean Tensile strength (Warp/Weft) : 179/123 N Mean Elongation (Warp/Weft) :...

Open the catalog to page 9
SWING-CONCEPT - 10

UmBi-liNK With pre-fixation system (IN-OUT) Prosthesis with centering and pre-fixation straight needles (IN/OUT) and a central positioning thread on round prosthesis (OUT/IN) Mean values given as an indication - Non-exhaustive reference list PrEFiX With pre-fixation system (IN-OUT) Prosthesis lined with a polyurethane impregnated bi-dimensional polyester mesh (113 g/m²) with pre-fixation system

Open the catalog to page 10
SWING-CONCEPT - 11

A complete solution for ventral hernia repair 11

Open the catalog to page 11
SWING-CONCEPT - 12

BIBLIOGRAPHY 1- «Which mesh for hernia repair ?» CN Brown, JG Finch, Ann R Coll Surg Engl 2010; 92: 272-278. 2 - «A review of available prosthetic material for abdominal wall repair» M Poussier, E Denève, P Blanc, E Boulay, M Bertrand, M Nedelcu, A Herrero, JM Fabre, D Nocca, Journal of Visceral Surgery (2013) 150, 55-62. 3 - «Enquête rétrospective Swing-Contact®» THT, 15/10/2012 rev3 sur 3867 prothèses posées par 31 chirurgiens. 5 - «The search for ideal hernia repair; mesh materials and types» Y Bilsel, I Abci, International Journal of Surgery 10 (2012) 317 - 321. 6 - «Les biomatériaux à...