Overview
The XT-4000i is a sophisticated haematology analyser utilizing fluorescence flow cytometry for precise analysis of blood and body fluids. It offers extended diagnostic capabilities, including reticulocyte and immature granulocyte counts, and is designed for high-quality, cost-efficient operation.

Key Features
  • Fluorescence Flow Cytometry: Analyzes RNA/DNA content, cell size, and complexity for accurate results.
  • Dedicated Body Fluid Mode: Provides counts for white and red blood cells in cerebrospinal and other body fluids without manual preparation.
  • Reticulocyte Technology: Distinguishes between mature and immature reticulocytes, aiding in anaemia diagnosis.
  • Immature Granulocyte Count: Offers superior clinical utility for detecting inflammation and infections.

Specifications
  • Body Fluid Mode: Counts for CSF, serous fluids, and synovial fluid, with information on inflammatory processes.
  • White Blood Cell Differential: Includes detection and monitoring of inflammations and infections.
  • Red Blood Cell Analysis: Evaluates erythropoiesis efficiency and monitors therapy for anaemia.
  • Technology: Utilizes fluorescence flow cytometry and DC sheath flow for various diagnostic parameters.
  • Throughput: Processes up to 100 samples per hour.
  • Aspiration Volume: Varies from 40μL to 150μL depending on the mode.

Design and Usability
  • Compact Design: Small footprint with efficient reagent use and low aspiration volume.
  • Automation: Features a 50-tube auto-sampler and STAT function for emergency samples.
  • Maintenance: Minimal daily maintenance required with automated shutdown sequence.

Contact Information
Sysmex Europe GmbH, Bornbarch 1, 22848 Norderstedt, Germany. Phone: +49 (40) 527 26 0, Fax: +49 (40) 527 26 100, Website
See more

Catalog excerpts

XT-4000i-1

XT-4000i * Fluorescence flow cytometry for high quality haematology analysis * More than blood alone – a dedicated mode for body fluids * Extended Diagnostic Capabilities on board (IG, Ret, Ret-He, IRF) * Sysmex Gold standard reticulocyte technology for monitoring erythropoietic status (Ret, Ret-He, IRF) * Online QC, optimised workflow, cost-efficient reagent consumption XT-4000i – Outstanding diagnostics plus dedicated body fluid analysis The XT-4000i really is an outstanding haematology analyser. Using Sysmex’s unique fluorescence flow cytometry, the analyser looks at RNA/DNA content, cell size and inner cell complexity rather than just cell size. This generates remarkably accurate results and a superb WBC differential. For those who need special capabilities, the XT-4000i has a separate, dedicated true body fluid mode. It has Sysmex’s famous gold standard reticulocyte technology on board as standard for monitoring erythropoietic status (Ret, Ret-He, IRF), as well as true quantitative IG counting instead of mere flagging. And it is particularly precise for RBC and PLT parameters thanks to hydrodynamic focusing. The analyser is practical and can be adapted to your own particular workflow. You will appreciate its cost-effective reagent consumption, and the fact that you can adapt the diagnostic sensitivity to your own laboratory needs through its unique Q-flags. You can also attach it to our network communication system for online quality control. Dedicated body fluid mode Analysing body fluids (BF), particularly cerebrospinal fluid (CSF), requires great focus from the laboratory since the specimen material is so delicate. This, and the many manual preparatory steps, mean analysis results tend to vary greatly, and so impair the information that is so crucial for clinicians and their patients. The XT-4000i provides a count for white and red blood cells found in CSF and other body fluids, as well as a total nucleated cell (TNC) count. This count can include macrophages, erythrophages, tumour cells, mesothelial cells and plasma cells, if present. Thanks to our expertise in cell counting technology, you can now count and classify particles even in low concentration ranges. You no longer have to specially prepare the sample material. Simply hold the sample tube under the instrument’s aspiration needle and it does the cell counting for you automatically. True reticulocyte count Using fluorescence flow cytometry, reticulocytes can be distinguished from mature red blood cells and white blood cells. You can reduce the interference between these cells to a minimum and even distinguish and quantify mature and immature reticulocytes. This leads to far more accurate results. Anaemia is often underestimated as a functional condition of red blood cells. But only the combined information provided by quantity- and quality-related reticulocyte parameters provides the whole picture behind anaemia diagnosis. Design and specifications may be subject to change due to further product development. Sysmex Europe GmbH, Bornbarch 1, 22848 Norderstedt, Germany, Phone: +49 (40) 527 26 0, Fax: +49 (40) 527 26 100 www.sysmex-europe

 Open the catalog to page 1
XT-4000i-2

The XT-4000i can deliver this information as standard. Compared to the haemoglobin value or other RBC parameters, the RET-He value and parameter combinations enable significantly faster control during iron and/or erythropoietin therapy. True immature granulocyte count To increase your analytical possibilities, your XT-4000i offers a classic 5-part differential and a true immature granulocyte (IG) count, with far superior clinical utility than the flagging offered by other technologies. IG supports the quick detection of inflammation and infections, and lets you monitor treatment. It also means...

 Open the catalog to page 2
XT-4000i-3

Diagnosis of MDS (NEUT-X) Extended red blood cell analysis Efficiency evaluation of erythropoiesis (RET-He, IRF, RPI) Therapy monitoring with anaemia of chronic diseases (RET-He) Differential diagnosis of iron deficiency anaemia, haemolytic anaemia or thalassaemia (RET-He, %HYPO-He, %MicroR, FRC, RBC-He, Delta-He) Technology fluorescence flow cytometry: WBC DIFF, IG, RET, IRF, PLT-O DC sheath flow: PLT, RBC, HCT; SLS method (cyanide-free): HGB Diagnostic parameters whole blood mode: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT%, LYMPH%, MONO%, EO%, BASO%,...

 Open the catalog to page 3

All Sysmex Europe catalogs and technical brochures

  1. CA-620

    3  Pages

  2. UC-3500

    2  Pages

  3. XN-CBC

    7  Pages

Archived catalogs

  1. XN-550

    2  Pages

  2. XN-1000

    2  Pages

  3. XN-9000

    1  Page

  4. DI-60

    2  Pages

  5. pocH-100i

    3  Pages

  6. DigniLife

    2  Pages

  7. XN-2000

    2  Pages

  8. XT_4000i

    6  Pages

  9. XN-3000

    2  Pages

  10. XN-1000 Pure

    2  Pages

  11. UD-10

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.