Systec laboratory autoclaves
15Pages

{{requestButtons}}

Catalog excerpts

Systec laboratory autoclaves - 1

SYSTEC LABORATORY AUTOCLAVES Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves.

Open the catalog to page 1
Systec laboratory autoclaves - 2

Systec Blindtext Systec Blindtext SYSTEC - THE AUTOCLAVE COMPANY

Open the catalog to page 2
Systec laboratory autoclaves - 3

Systec - the autoclave company Systec laboratory autoclaves THE POWER OF INNOVATION. FOR BETTER STERILIZATION. Experience counts Systec laboratory autoclaves We only make two things. Laboratory autoclaves and devices for the improved sterilization and handling of culture media. Always with the goal of making laboratory work safer, easier, more accurate, reproducible and validatable, and consequently more economical. With over 25 years of experience and continuous intensive cooperation with experts and users, we know how to provide optimal solutions for even the most complex sterilization...

Open the catalog to page 3
Systec laboratory autoclaves - 4

Systec H-Series / H-Series 2D SYSTEC H-SERIES. HORIZONTAL FLOOR-STANDING AUTOCLAVES. Autoclaves for all laboratory applications, even for sophisticated sterilization processes. The new, improved generation of Systec H-Series autoclaves comes in a new design, with a fully revamped interior and a completely new touchscreen control. The combination of new features guarantees higher work precision, easier maintenance of devices, shorter and more efficient process times. All Systec autoclaves can be upgraded on a modular basis, with options and equipment to optimize sterilization processes for...

Open the catalog to page 4
Systec laboratory autoclaves - 5

Systec H-Series / H-Series 2D SYSTEC H-SERIES 2D. PASS-THROUGH AUTOCLAVES. Triple safety aspects ■ One door only can be opened at a time. If one door is open, the other is automatically locked. ■ If the autoclave is switched off or if no current is available (e.g. power failure), both doors remain locked. ■ If the door at the non-sterile side is opened, a sterilization program has to be performed before the door at the sterile side can be opened. The locking system can be adapted to customers' wishes. The doors and control panel are made of heat-insulating polyurethane. The housing is...

Open the catalog to page 5
Systec laboratory autoclaves - 6

Systec H-Series / H-Series 2D Standard Features Integrated steam generator separated from the chamber Housing, support frame and pressure chamber, made of corrosion-resistant stainless steel SYSTEC H-SERIES, SYSTEC H-SERIES 2D. AVAILABLE WITH FOUR CHAMBER DIAMETERS. Temperature and pressure range 140 °C, 4 bar absolute pressure The pressure vessel of the autoclave is made of corrosion-resistant stainless steel 1.4404 (AISI 316L) All connections on the pressure vessel are designed as Tri-Clamp All fittings and valves in the supply lines (from media connection to sterilization chamber) for...

Open the catalog to page 6
Systec laboratory autoclaves - 7

PERFECT DESIGN AND CONSTRUCTION. INNOVATIVE TO THE LAST DETAIL. State-of-the-art engineering Systec autoclaves are state-of-the-art, both in their mechanical and electrical components; ensuring a new quality of laboratory sterilization processes. The enhanced components enable the lab to meet all requirements for today and for the future. All-round quality The pressure vessel is made of corrosion-resistant stainless steel 316L (1.4404), which makes cleaning easy. The autoclave support framework and housing are also made of stainless steel. An approved safety valve for excess pressure is...

Open the catalog to page 7
Systec laboratory autoclaves - 8

Control and Documentation PERFECT DESIGN AND CONSTRUCTION INNOVATIVE TO THE LAST DETAIL. EVERYTHING UNDER CONTROL. Steam generation by steam generator A separate steam generator is incorporated in the housing. This has numerous advantages: ■ No heating elements and no reservoir for dirty water in the chamber. ■ In conjunction with the standby pre-heating function, only 10 min. heating time to reach 121 °C with an empty chamber (smaller autoclaves, e.g. Systec HX-65) are required. ■ Improved air removal by forcing the air to the bottom of the chamber via gravitation. The air is eventually...

Open the catalog to page 8
Systec laboratory autoclaves - 9

THE POSSIBILITIES OF DOCUMENTATION. Internal memory STANDARD The internal memory for process data uses the internal storage; this is part of the Systec PLC. The capacity is sufficient to store process data over an average period of minimum 10 years. The integrated documentation feature is used for comprehensive batch documentation and for exporting the electronic data as PDF or CSV via network interface* or USB. The essential values of the individual program phases and process parameters are presented in a tabular overview, followed by a graph and a numerical table of the program sequence....

Open the catalog to page 9
Systec laboratory autoclaves - 10

STERILIZATION OF LIQUIDS. Cooling Radial ventilator Systec supplies autoclaves guaranteeing precise sterilization processes, safe handling and increased productivity. Numerous cooling functions are available for liquid sterilization. Many of these functions are equipped as standard or available as options depending on the model range selected. Various optional rapid cooling systems enable the cooling times for liquids to be significantly reduced. This conserves culture media and makes utilization of the autoclave more efficient. New system- and process technology now make it possible to...

Open the catalog to page 10
Systec laboratory autoclaves - 11

STERILIZATION OF SOLIDS AND WASTE IN DISPOSAL BAGS. STERILIZATION OF BIOLOGICAL SUBSTANCES. Vacuum system Permanently monitored – exhaust air filtration with condensate inactivation Typical solids are pipette tips (in boxes), empty glassware and waste in bags as wall as porous materials such as filters or fabrics. For this type of sterilization, it is important to remove all air from the products to be sterilized in order to ensure precise, reproducible and validatable sterilization results. The vacuum device effectively removes the air from solids, tubing, porous materials, fabrics and...

Open the catalog to page 11
Systec laboratory autoclaves - 12

Custom Developments SYSTEM ACCESSORIES FOR EASE OF HANDLING. CUSTOM DEVELOPMENTS FOR SPECIAL APPLICATIONS. Systec H-Series and Systec H-Series 2D Additional features and programs Transport cart and transfer cart with Easy Load Large autoclaves in particular can be easily and securely loaded using special transport and transfer carts. The items to be sterilized can either be placed directly on the transfer cart with rails or using a basket. The transport cart can be moved and docked to the autoclave and fixed in position. The handle can then be loosened to allow the transfer cart to slide...

Open the catalog to page 12