"Powered by Self Quality"
Open the catalog to page 1wprpcl hw colf Oiialitv" DESIGN FEATURES AND SUPERIORITIES HSK patented special sealing design with double gasket that prevent air leakages. (1) ' HSK patented Aluminium profile intersected system with no need for panel - aluminium profile connections. 1 Robust frame with special aluminium profile. 1 High quality double skinned construction with B2 fire resistance class polyurethane injected panels insulates heat and sound. (2) 1 Outer skin is 0,5 mm sheet metal coated with aluzinc prepainted with epoxy and coated with plastic protective film. ' Inner skin is 0,5 mm galvanized sheet metal. 130...
Open the catalog to page 2Quick Selection Chart Capacity Chart Speed (rri/h) Air Volume - Cooling or Heating Capacity Nomogram Example: Finding the necessary cooling capacity to cool the exterior air with a dry bulb temperature of 30 °C and a relative humidity of 40% to the conditions of 13 °C and 85% with an AHU with a flow The specified points are marked on the psychometric diagram, and the enthalpy values of these points are determined. By moving on the arrow direction from the points 1 ' and 2', the 3 intersection points are obtained. The capacity is read from the top axis by Intersecting the diagonal showing 10.000...
Open the catalog to page 3SECTIONS DIMENSIONS AND WEIGHTS 1. Heating section (IB) weights have been prepared for 1 row of coil. 2. Cooling section (SB) weights have been prepared for 4 rows of coil. HSK is entitled to make changes on the technical specifications of the products due to continuous product development studies.
Open the catalog to page 4Electric Heater Section Cooling Coll Section Heating & Cooling Section Single Damper Double Damper Section Mixing Section Silencer Section S1 : 25 dB (A) Loss Active Carbon Filter Section Hepa Filter Section Plate Type Heat Recovery Section Rotary Type Heat Recovery Section Expanded Filter Panel Filter Section Empty Section Evaporative Humidifier Section Steam Humidifier Section Atomizing Humidifier Section
Open the catalog to page 5Air Handling Units Components Radial Fans can be used in forward or backward inclined bladed structure, in a structure which does not create sparks with accessories. Radial fans which have been produced of completely galvanized sheets, and the static and dynamic balances of which have been set with double suction. They are produced equipped with optional spring isolators and frequency Electric Motors The 380 V motors with 50 Hz, with 3 phases, of the insulation class F, the protection class IP 54 and with 2, 4 and 8 poles are selected an average of 20% higher than the shaft power of the fan....
Open the catalog to page 6It is possible to select several humidifiers of different types, • Adiabatic Vaporization Pad Type: Stainless steel drainage pan, cellulose based vaporization pad, pump, float, suction filter are standard. • Electronic Steam Type : Steam cylinder, immersed electrodes, stainless steam distributor and electronic control module are standard. • Electronic Ultrasonic Type : Ultrasonic, vibration plates, deionization equipment electronic control module are standard. • Atomizing Water Spray Type : Nozzles and PVC - based distribution pipes, water level adjuster, water pump, suction filter aluminium...
Open the catalog to page 7"Powered by self Quality" Factory / Export / Technical Service ISISO Sanayi Sitesi 2. Kisim V2 Blok No: 7/8 Hadimkoy 34555 Istanbul / TURKEY e-mail: [email protected] HSK9lis the registered trademark of Havalandirma End. San. Tic. Ltd. Sti.