Catalog excerpts
Blueline Design Features and Superiorities • ystemair patented special sealing design with double gasket that prevents air S leakages. (1) • ystemair patented aluminium profile intersected system with S no need for panel - aluminium profile connections. • obust frame with special aluminium profile. R (1) • igh quality double skinned construction with B2 fire resistance class H polyurethane injected panels insulates heat and sound. (2) • uter skin is 0,5 mm sheet metal coated with aluzinc prepainted with O epoxy and coated with plastic protective film. • nner skin is 0,5 mm galvanized sheet...
Open the catalog to page 2Blueline Quick Chart Section Capacity Chart MODEL Air Volume - Cooling or Heating Capacity Nomogram Diagram Use Qt = Qs - Ql Qs ~ 1,2 x V x dT/3600 in kW Qt ~ 2,95 x V x dx/3600 in kW t... Total Heat s... Sensible Heat I... Latent Heat Example: Finding the necessary cooling capacity to cool the exterior air with a dry bulb temperature of 30 ºC and a relative humidity of 40% to the conditions of 13 ºC and 85% with an AHU with a flow of 10.000 m3/h. The specified points are marked on the psychometric diagram, and the enthalpy values of these points are determined. By moving on the arrow...
Open the catalog to page 3Blueline Section Dimensions and Weights DIMENSIONS (L) 1. Heating section (IB) weights have been prepared for 1 row of coil. 2. Cooling section (SB) weights have been prepared for 4 row of coil. Systemair is entitled to make changes on the technical specifications of the products due to continuous product development studies.
Open the catalog to page 4Panel Filter Active Carbon Filter Sections Low Depth Filter Section Electric Heater Heating Coil Cooling Coil Section Section Section Section Aspirator / Ventilator Hepa Filter Section Silencer Sections Heating & Cooling Coil Single Damper Double Damper Mixing Section Adiabatic Spray Adiabatic Vaporization Steam Humidifier Plates Type Heat Rotating Heat Empty Section Humidifier Section Humidifier Section Section Recovery Section Recovery Section
Open the catalog to page 5Blueline Air Handling Units Components Fans Radial Fans can be used in forward or backward inclined bladed structure, in a structure which does not create sparks with accessories. Radial fans which have been produced of completely galvanized sheets, and the static and dynamic balances of which have been set with double suction. They are produced equipped with optional spring isolators and frequency inverter. Electric Motors The 380 V motors with 50 Hz, with 3 phases, of the insulation class F, the protection class IP 54 and with 2, 4 and 8 poles are selected an average of 20% higher than...
Open the catalog to page 6Blueline Moisturizers It is possible to select several humidifiers of different types. • diabatic Vaporization Pad Type: A Stainless steel drainage pan, cellulose based vaporization pad, pump, float, suction filter are standard. • lectronic Steam Type: E Steam cylinder, immersed electrodes, stainless steam distributor and electronic control module are standard. • lectronic Ultrasonic Type: E Ultrasonic, vibration plates, deionization equipment electronic control module are standard. • lectronic Ultrasonic Type: E Nozzles and PVC - based distribution pipes, water level adjuster, water pump,...
Open the catalog to page 7Systemair - Turkey Ömerli Mah. İhsangazi Sok. Hadımköy Yolu No: 28 34555 Hadımköy / İstanbul Tel : +90 212 623 22 10 Fax : +90 212 623 22 15
Open the catalog to page 8All Systemair HSK catalogs and technical brochures
-
AQWL/AQWH/AQWR 1404 to 2406
48 Pages
-
VLS/VLH/VLR 524 to 1204 NEW
52 Pages
-
Kälte- und Klimasysteme
208 Pages
-
Fan Coil
16 Pages
-
Water Source Heat Pump
8 Pages
-
Heat Recovery Fresh Air Unit
8 Pages
-
Axial Heating Unit
8 Pages
-
High Pressure Fan Coil Units
8 Pages
Archived catalogs
-
Fan Coil - 2014
8 Pages
-
CEILING TYPE
4 Pages
-
POOLLINE AIR HANDLING UNIT
4 Pages
-
MEDILINE PACKAGE HYGIENE
8 Pages
-
hsk
72 Pages
-
hygienline
8 Pages
-
Flexine catalog
12 Pages
-
blueline catalog
8 Pages