Based on the ambitious, developing, and innovative structure, HSK has accepted the worldwide known standards as the reference and developed Flexline Series Air Handling Units in accordance with the developing customer requirements, 50 mm rock wool filled panels are used to prevent thermal bridge in the construction of air handling units. Thus the formation of the condensation on panel surfaces has been prevented and the body thermal transmittance is minimized. The air leakage has been decreased with the help of special bolts which have been placed on top of the body profiles. Air Handling...

Open the catalog to page 2
Flexine catalog - 3

The fast, sensitive, and flexible production provided by the CNC workbenches of the modern plants of HSK. The machines used in HSK production are equipped with the latest technologies developed in sheet metal processing industry." Frame Drill Technology The "FRAME DRILL" Technology, which is a CNC production machine, designed by HSK engineers, and patented in the year 2007 as the HSK's "AHU Production Technology". (Patent No: 2007 / 01635) Frame Drill Machine's CNC strength provides that the AHU casing profiles are processed with zero failure as standard. Thus, an AHU which has been created...

Open the catalog to page 3
Flexine catalog - 4

HSK FLEXLINE AHUs are unique and remarkably different from the other types of AHUs with its panel design, galvanized steel frame, and its insulated stainless steel condensation pan. Galvanized steel box profiles of a dimension of 30x30 - 30*60, and thickness of 2mm are used in order to increase the rigidity of the casing and to provide for the assembly of the panels. The connection of the profiles with corner elements are made of cast aluminium materials. The connection of the panels to the frame is provided with screws which has protective covers used as the precaution against corrosion....

Open the catalog to page 4
Flexine catalog - 5

Radial Fans Radial fans with front or backward curved blades, with double inlet-double width are used. The bearing of the fans have at least 40,000 hours of service life. The fans can be used in an optional spark proof structure, which prevents sparks during the process. Another fan option is high temperature smoke exhaust ability. Depending on the place where the electrical motor is used, the optional IP54, IP55, IP65 protection, and EFF1, EFF2 energy classes can be selected. Standard motors have F insulation class that includes 380 V 50 hz three-phase, full covered, short circuit rotor...

Open the catalog to page 5
Flexine catalog - 6

Electrical Heaters It is produced as sheet coil fins on electrical heaters, stainless steel pipe, and steel fins as a standard. The safety thermistor and the differential pressure switch are located in the electrical heating section as a standard. There is also a connection panel which has been installed onto the heater section and which enables the resistance connections. Thus, a connection can be established easily with the main panel of the building where all the protections are realized. Heat Recovery The indoor air carries some energy, It is possible to recover this energy with the...

Open the catalog to page 6
Flexine catalog - 7

Different types of humidifiers can be used for humidifying purposes. Adiabatic Vaporization Humidifiers The water pool is produced as stainless steel sheet metal or electrostatic painted galvanized steel sheet, according to customer needs. Specially designed cellulose humidifying pads are used in the system. Inside the pool there is a circulation pump and distribution collector which enables the water to be sent to the pads. Inside the pool, there is a floater which enables the decreasing water to be completed, and in addition to overflowing, water discharge inlet and outlets are also...

Open the catalog to page 7
Flexine catalog - 8

Heat Recovery Units Heat Recovery Unit with Heating Pipe: Operates in a regenerative manner. In this system, coolant is used to transfer the heat; coolant evaporates and rises inside the tube when it encounters the system return air and condenses again upon transferring its heat to cold air and the system operates according to this principle. The system operates problem-free between temperatures -30°C and 55°C. Heat recovery cell is equipped with a bypass damper in order to control the air flow. Heating piping can be arranged side-to-side in a horizontal manner or on top of each other in a...

Open the catalog to page 8
Flexine catalog - 9

Quality Management System Safety Management Systems Environmental Management TSEK EUROVENT Certificate GOST Certificate CE Air Handling Units Certificate Quick Selection Chart Selection is possible in a wide airflow range changing between 1.000 m3/h and 100.000 nf/h. 2,8 m/s on coil velocity and low AHU internal pressure losses. Velocity Range

Open the catalog to page 9
Flexine catalog - 10

Adiabatic Washer Humidifier Base A = 300 mm Aspirator / Ventilator Section Electric Heater Section Coil Section Cooling Coil Section Active Carbon Filter Sections Panel Filter Section Low Depth Filter Section Hepa Filter Section Silencer Sections

Open the catalog to page 10
Flexine catalog - 11

SECTION WEIGHTS Heating & Cooling Coil Section Single Damper Section Double Damper Section Mixing Section Adiabatic Spray Humidifier Section Adiabatic Vaporization Humidifier Section Steam Humidifier Section Plates Type Heat Recovery Section Rotating Heat Empty Section Recovery Section

Open the catalog to page 11
Flexine catalog - 12

"Powered by self Quality" Factory / Export / Technical Service ISISO Sanayi Sitesi 2. Kisim V2 Blok No: 7/8 Hadimköy 34555 Istanbul / TURKEY e-mail: hsk@hsk.com.tr HSK*'is the registered trademark of Havalandirma End. San. Tic. Ltd. Sti.

Open the catalog to page 12

All Systemair HSK catalogs and technical brochures

  1. Fan Coil

    16 Pages

  2. Blueline

    8 Pages

Archived catalogs

  1. CEILING TYPE

    4 Pages

  2. hsk

    72 Pages

  3. hygienline

    8 Pages