Open the catalog to page 1Ecology units? Ecology units are ventilation equipment tailored to address the requirements of kitchen exhaust systems. The units play a vital role in maintain the indoor air quality, which is crucial in environments where grease, smoke, and odour particles emitted from cooking have negative effects on human health and impacts comfort conditions in homes, restaurants, hotels, and other sensitive hospitality and entertainment venues. If left untreated, the accumulation of volatile organic compounds (VOCs) and other particulate matter released during cooking in ducts of exhaust equipment leads...
Open the catalog to page 3The most significant design criterion in the selection of ecology units is the type of catering establishment. Since the amount of grease, steam, and particles in the exhaust air will vary according to the type of food cooked, different models are suitable for various kitchens. We can divide common catering establishment types under four main categories according to the expected density of odour and grease. This classification of low, medium, high, and heavy density kitchen types can be seen in the following table. Light density: Standard kitchen exhaust fans suitable for continuous high temperature...
Open the catalog to page 4How does the electrostatic precipitator work? In an Ecology Unit, the Electrostatic Precipitator (ESP) is the most crucial part of the system, as they are the components that trap most of the dust and grease particulates. As air passes into the combined ionizer/collector cell, the particulates in the air stream are polarised to a negative potential. As they continue through the ioniser and between the collector cell plates, the polarised particulates are repelled away from the negatively charged plates and attracted to the earthed plates where they stick. This allows the particulates to be filtered...
Open the catalog to page 5Geniox VOClean • High efficient electrostatic precipitator Ozone producing, high energy UV-C lights. Removing grease, smoke and odour from the air by ionizing the particles. • High efficient electrostatic precipitator Secondary ESP stage for high density grease and particle control. • Post mesh filter Casing Thermal insulation class Thermal bridging class Deflection class Air leakage class Filter by-pass class Provides longer lifespan for the activated carbon filter by filtering parti
Open the catalog to page 6EPA/HEPA filter Activated carbon filters Provides longer lifespan for the activated carbon filter by filtering particles. Removes odour from the air with its high contact time and carbon weight. Service and maintenance All doors provide easy access for cleaning and service. High efficient plug Fan motor Direct driven plug fan with standard IE3 motor efficiency.
Open the catalog to page 7Metallic filter unit HEPA filter unit Active carbon filter unit a Odour neutralising unit Silencer unit
Open the catalog to page 8Unit properties Minimum carbon contact time (s) Active carbon filter Voltage/phase/frequency Fan motor power* (kW) Fans were selected at 300 Pa external pressure drop. Systemair reserves the right to modify these values. Please contact Systemair sales office for exact unit selections.
Open the catalog to page 9Options UVV technology UV technology is used efficiently in kitchen ventilation as well as in many other applications around the world. Ultraviolet rays are divided into three as A-B-C. UVV rays are in the wavelength range of 100-200 nm. As ozone (O3) is produced within this range, optimum wavelength value is accepted as 185nm. UV rays with a wavelength of 185 nm, which are frequently used in kitchen applications, allow photolysis and ozonolysis processes. While the bonds between the atoms forming the oil particles are broken by photolysis, the oxygen (O2) atoms in the air are separated in the...
Open the catalog to page 10High temperature applications Some cooking methods and kitchen applications feature high temperature handling while extracting the air. In these conditions, standard equipment and design may not be sufficient or the heavy requirement might lead to the system losing its function after a short period of time. This leads to higher cost in terms of maintenance of possible replacement of equipment. Systemair offers completely modified casing and equipment selections to avoid risks caused by high temperatures. The unit can be configured to run continuously up to 120°C. Everything is under control!...
Open the catalog to page 11As part of the exhaust system in industrial kitchens, cooker hoods play an important role. It is recommended by authorized institutions and organizations to use make-up air hoods to balance the air in the kitchen Some of the cooker hood applications Systemair can offer with Geniox VOClean: • Exhaust only • Exhaust only, for low ceiling • Exhaust with air jet and air supply Please contact Systemair sales offices for special configurations for your project.
Open the catalog to page 12Discover Geniox VOClean with virtual reality! HVAC Products PRO by Systemair Available for everyone without registration, downloadable in a single click, or by scanning the QR code below. You can explore Geniox VOClean with real-time data wherever and whenever you want. Observe Geniox VOClean in eight different kitchen types arranged according to the densities determined by ASHRAE 154. The unit comes with the configurations we recommend and with all the other filter groups you want to try. Bring real-time operation data at your fingertips! Which ecology unit is suitable for your kitchen? Find...
Open the catalog to page 13• Wt#ts ' '• SpsrapMs btuiixi Writ/loch Hm/atfiBnj
Open the catalog to page 14Airware PRO selection software Airware Pro is the brand new selection software we use for modular and compact air handling units. The software provides a detailed overview of all functions and dimensions of the compact and modular air handling units selected. Geniox VOClean ecology unit can be selected via Airware Pro, which offers quick access to capacities and energy consumption values. Air handling unit templates have been pre-configured in the software to facilitate quick selection. In this way, customers can modify these templates according to their needs. After the air handling unit has...