1. Catalogs
  2. Systemair HSK
  3. Hygiene line Air Handling Unit Catalogue

Hygiene line Air Handling Unit Catalogue

Hygiene line Air Handling Unit Catalogue

Hygiene line Air Handling Unit Catalogue

Product catalog summary
General Features
The Hygiene Line Air Handling Unit, developed by Systemair, is designed for clean rooms and hospital buildings to ensure fresh and clean air. It features a design that prevents dust and dirt accumulation, with smooth surfaces and hidden frames. Standard features include observer glass and internal lights for easy inspection. The unit complies with EN 1886 standards, eliminating thermal bridges to prevent condensation.

Specifications
- Flow rate: 100 m3/h to 100,000 m3/h
- Modular construction
- Environmentally friendly materials
- Compliance with VDI 6022-1, VDI 6022-3, DIN 1946-4, EN 13053
- Sealed with antibacterial gaskets

Construction
The unit features a robust panel and frame construction with thermal insulation and PVC profiles to prevent humidity. It is designed without thermal bridges and includes easily cleanable illumination armatures.

Corrosion Resistance
The unit uses galvanized or stainless steel with baked powder paint for corrosion resistance. It includes stainless steel heat exchangers and drain pans, and low-pressure drop drip eliminators.

Sealing Components
The unit uses neoprene-based gaskets resistant to disinfectants and cleanable both chemically and physically.

Fans and Filters
The unit uses cleanable free-running impeller fans suitable for speed control. Filters are designed to prevent leakage and microbiological growth, with easy maintenance features.

Coils
Coils are accessible for cleaning and maintenance, with stainless steel frames and epoxy-coated fins for corrosion protection.

Software and Testing
Systemair's Airware software facilitates the selection and application of units. Performance is tested in accordance with ANSI/AMCA standards, with results reported using Lab view software.

Production Processes
Units are selected and evaluated for efficiency, with materials checked for quality. Production uses CNC machinery, and products are tested for compliance with standards.

Sections and Models
The document includes detailed specifications for various sections and models, including dimensions and weights for different configurations.
See more

Catalog excerpts

Hygiene line Air Handling Unit Catalogue-2

Hygiene Line General Features Hygiene Line Air Handling Unit was developed based on the experiences and the quality concept of Systemair as a new member of Systemair product family. Hygiene Line was developed by the Research & Development department of Systemair in order to ensure the fresh and clean air fort he air conditioning inside the clean rooms and hospital buildings. The basic logic during the design of Hygiene Line Air Handling Unit was to create a structure what prevents the accumulation of dust and dirt inside the units also to be easily cleaned and can be checked by inspector. Since...

 Open the catalog to page 2
Hygiene line Air Handling Unit Catalogue-3

Hygiene Line Quick Selection Table Construction • Framework consisting of profiles hot dip galvanized and then finished with baked powder paint • Robust panel and frame construction, class “2A” according to EN 1886 • Panels thermally insulated with 50 mm rock wool • PVC profiles with 7 chamber air pockets consists heat brake while connecting internal and external surfaces of the panels • Designed without thermal bridge that prevents the occurrence of humidity in the body • Sealed with closed cell gaskets • IIIumination armatures set - in panels, which do not extend in the section and can be cleaned...

 Open the catalog to page 3
Hygiene line Air Handling Unit Catalogue-4

Hygiene Line Sealing Components • Preventing microbiological growth • Neoprene based, resistant against disinfectants • Chemically and physically cleanable. Fans Cleanable free running impeller fans (without fan scroll) are used. Such fans are appropriate for speed control using the frequency converter. Elimination of vibration with vibration isolators and flexible apparatus connections. Filters Since the pressure drop of a filter will be low while it is clean and it will be high while it is dirty, it is not appropriate to use both of them while the filters are selected. Therefore, the average...

 Open the catalog to page 4
Hygiene line Air Handling Unit Catalogue-5

Hygiene Line “Airware” Air Handling Unit Selection Software Airware selection software of Systemair allows the selection of Hygiene Line Air Handling Units and execution of all kinds of applications of these units. With Airware air handling selection software developed by Systemair engineers, any air handling unit with required features can be selected very fast, easy and safely. Performance Test Room Airflow measurement test room was built in accordance with ANSI/AMCA 210-85 standards in order to measure the airflows of the produced air handling units. The performance room allows monitoring...

 Open the catalog to page 5
Hygiene line Air Handling Unit Catalogue-6

Hygiene Line AS / VA Aspirator / Ventilation Section IB Heating Coil Section EL Electric Heater Section SB Cooling Coil Section IS Heating & Cooling Coil Section D1 Single Damper Section D2 Double Damper Section YN Adiabatic Spray Humidifier Section PN Adiabatic Vaporization Humidifier Section PR Plates Type Heat Recovery Section RR Rotating Heat Recovery Section

 Open the catalog to page 6
Hygiene line Air Handling Unit Catalogue-7

Hygiene Line Foot height is 150 mm. H and B are measurements external measurement. H-80 and B-100 shold be canculated for internal measurements. Air Flow Cross Section DIMENSIONS (L) MODEL SECTION

 Open the catalog to page 7
Hygiene line Air Handling Unit Catalogue-8

Systemair - Sweden Industrivägen 3-SE 739 30 Skinnskatteberg / Sweden Tel : +46 222 440 00 Fax : +46 222 441 00 Systemair - Turkey Ömerli Mah. İhsangazi Sok. Hadımköy Yolu No: 28 Hadımköy / Arnavutköy / İstanbul / Turkey Tel : +90 212 623 22 10 Fax : +90 212 623 22 15 [email protected] www.systemair.com.tr www.systemair.com

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.