Poolline Air Handling Unit Catalogue

Poolline Air Handling Unit Catalogue

Poolline Air Handling Unit Catalogue

Product catalog summary
Overview: The document discusses the importance of controlling humidity in indoor pool areas to prevent structural damage and health issues. Systemair Poolline 'HPL' Air Handling Units are designed for dehumidification, enhancing energy efficiency and reducing operational costs.
Key Features:
  • Air flow capacity ranges from 2,500 to 15,000 m3/h.
  • Dehumidification capacity between 15 to 90 kg/h.
  • Components are corrosion-resistant, with epoxy-coated aluminum and stainless steel materials.
  • Energy-efficient with heat recovery systems and microprocessor control for various operational modes.
Operational Modes:
  • Night Operations: Options for dehumidification with 100% inside air, compressor on or off.
  • Day Operations: Mixing of return and outside air for dehumidification, compressor on or off.
  • Seasonal Transitions: Utilizes maximum outdoor air for ventilation and dehumidification.
Technical Specifications:
  • Cooling capacity ranges from 17 to 101 kW.
  • Water heating capacity ranges from 26 to 169 kW.
  • Heat recovery capacity ranges from 8 to 48 kW.
  • Dimensions and weights vary across models, with the largest model weighing 2,530 kg.
Conclusion: Systemair's Poolline units provide a comprehensive solution for maintaining optimal humidity levels in indoor pool environments, ensuring structural integrity and health safety.
See more

Catalog excerpts

Poolline Air Handling Unit Catalogue-1

Poolline Air Handling Units

 Open the catalog to page 1
Poolline Air Handling Unit Catalogue-2

Poolline Air Handling Units for Dehumidification of Indoor Pool Areas When the humidity is not controlled at indoor pool areas, it decreases the comfort conditions and damages the building. During the months of winter and in cool summer evenings, the outside air temperature can become visibly lower than the indoors air temperature. Warm air holds humidity; but cold walls or window surfaces can cause condense. When the relative humidity gets above 62 % for a long time, it starts harming the structure. Chlorine, which evaporates from the chemicals pool water, combines with the condensed moisture...

 Open the catalog to page 2
Poolline Air Handling Unit Catalogue-3

Poolline POOLLINE TECHNICAL SPECIFICATIONS TABLE TYPE POOL SURFACE DEHUMIDIFICATION CAPACITY COOLING CAPACITY WATER HEATING CAPACITY HEAT RECOVERY CAPACITY SUPPLY SIDE EXTERNAL PRESSURE EXHAUST SIDE EXTERNAL PRESSURE CONDENSER CAPACITY EXHAUST MOTOR POWER SUPPLY MOTOR POWER ELECTRICAL CONSUMPTION DIMENSIONS TYPE HEATING COIL INLET / OUTLET PIPE DRAIN PAN OUTLET PIPE DIAMETER AMBIENT CONDITIONS AT 55 % RELATIVE HUMIDITY AND 3O °C OUTDOOR AIR CONDITIONS +5 °C AND 85 % RELATIVE HUMIDITY ALL THE SELECTION FOR THE FINAL HEATER CAPACITY (STANDARD) AT WATER TEMPERATURE IS 80 / 60 °C WITH 30 % FRESH...

 Open the catalog to page 3
Poolline Air Handling Unit Catalogue-4

Systemair - Sweden Industrivägen 3-SE 739 30 Skinnskatteberg / Sweden Tel : +46 222 440 00 Fax : +46 222 441 00 Systemair - Turkey Ömerli Mah. İhsangazi Sok. Hadımköy Yolu No: 28 Hadımköy / Arnavutköy / İstanbul / Turkey Tel : +90 212 623 22 10 Fax : +90 212 623 22 15 [email protected] www.systemair.com.tr www.systemair.com

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.