1. Catalogs
  2. T&D Corporation
  3. Wireless Monitoring System

Wireless Monitoring System

Wireless Monitoring System

Wireless Monitoring System

Product catalog summary
Overview
The document describes the T&D RTR-500 Wireless Data Logging System, designed for automatic monitoring of environmental parameters such as temperature, humidity, illuminance, and UV, particularly in settings like museums. The system facilitates remote monitoring and data collection without the need for manual intervention, ensuring continuous data logging even during power outages.

Specifications
The system operates independently of other building systems, using battery power and backup to maintain data collection during outages. It supports wireless installation, allowing data loggers to be placed in hard-to-access areas without the need for cables.

Procedures
The system includes a network capability for remote data monitoring and collection via LAN, WAN, or the Internet. Users can view and download data from remote locations to a central server. The system also provides warning notifications via email or SMS when preset limits are exceeded.

Software and Tools
The system includes several software applications for Windows, such as the RTR-500GSM, RTR-500W, RTR-500, and RTR-500DC, each offering tools for settings utility, temperature/humidity graphing, multi-scale graphing, data download, and adjustment.

WebStorage Service
T&D offers a WebStorage Service, allowing users to access and share data online. This service supports data transmission from compatible products to a dedicated Internet server, enabling data access from anywhere.

Recommendations
For optimal use, it is recommended to utilize the Settings Utility program for easy configuration of base unit settings and registration of remote units. Communication tests should be conducted to ensure stable signal strength between units.

Key Features
  • Automatic data collection and error-free record-keeping.
  • Wireless installation and remote monitoring capabilities.
  • Warning notifications for exceeded limits.
  • Comprehensive software tools for data management.
  • Online data access and sharing through WebStorage Service.
See more

Catalog excerpts

Wireless Monitoring System-1

Wireless Monitoring System Automatic Data Collection - Remote Monitoring - Wireless Installation Automatic Monitoring of Environmental Parameters For Museums

 Open the catalog to page 1
Wireless Monitoring System-2

The T&D RTR-500 Wireless Data Lo multi-point recording and reporting o data is then automatically downloade collection point without the need for collections means that archived recor Collect the Data- Not the Logger Opening display cases and climbing ladders to collect data loggerswhen you remember to, is a thing of the past. T&Ds automatic data collection system means that high value staff need not spend their time fetching data loggers, and can concentrate on being productive. Warning Not fic tion Warning Notification Warning Notification a Not f c o catio A of T&Ds ne rk c ected All of T&Ds...

 Open the catalog to page 2
Wireless Monitoring System-3

ror-Free Record Keeping ogging System allows for completely configurable, of temperature, humidity, illuminance and UV. Recorded ed and archived to a server or other centralized data human intervention. Automated data recording and rds will always be accurate and complete. Wireless Installation & Collection T&Ds wireless system means that monitoring and recording can be accomplished at measurement points that are difficult to access without the expense of running unsightly cables. With battery operation and wireless connectivity, T&D loggers can be placed almost anywhere. Remote Monitor Remote...

 Open the catalog to page 3
Wireless Monitoring System-4

T&D WebStorage Service is an online service provided by T&D Corporation. By setting up any of our compatible products to transmit recorded data and current readings to our dedicated Internet server, Users can use our WebStorage Service to access and share their data anytime from anywhere. l.unent Hcj.fcng*j H«cohM(MU|IK/| ( unm* Krutaia* D.K.i |XM 1 RTO-500AW oninn 06MO (RT»',nft*«V) Ch»om*fl Swnurw ff?TT?501) |tM| 3507 k |<hJJ00«5rrW [t mj 70 7 C IcM) J4 % [ch$J 5673000 b |cne| 84 96 mV* IthllCno. It h7< Enot TVtr Ht be unnracd modrh nckxVd <nx<n| thr Software Included with Base Unit RTR-500W...

 Open the catalog to page 4

All T&D Corporation catalogs and technical brochures

  1. TR4A

    1  Page

  2. TR7A

    1  Page

  3. RTR500B

    1  Page

  4. TR7A2 Series

    8  Pages

  5. TR-7nw

    4  Pages

  6. TR4A Series

    3  Pages

  7. RTR500B Series

    24  Pages

  8. RTR502B

    6  Pages

  9. TR-55i

    3  Pages

  10. MCR Series

    2  Pages

  11. TR-5I

    12  Pages

  12. RTR 500

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.