Catalog excerpts
In Vitro Diagnostic Biosensor Point of Care Testing Medical Device Vital Signs Monitor Pulse Oximeter Blood Pressure Monitor Telehealth Remote Monitoring Devices
Open the catalog to page 2Core Technology TaiDoc focus on 4 core technologies - Medical Electronics, Biochemistry, Photometry and Software Programming. We utilize our core technologies to develop products in In Vitro Diagnostics, Medical Device and Telehealth. Medical Electronics Based on the advanced electronics TaiDoc employs Photometric technology and IT capability in Taiwan, TaiDoc to develop devices for qualitative and develops minimized and user- quantitative measurement. friendly medical devices. Software Programming TaiDoc provides accurate TaiDoc develops the vertical software quantitative results in terms...
Open the catalog to page 3Provide 7 parameters for a comprehensive care 4 Glucose Ketone Cholesterol Triglycerides Uric Acid Hemoglobin Reaction Time (Seconds) Measurement Range (mmol/L) LAC LACtate tate LACtate L AC LACtate LACtate tate LACtate L LAC AC LACtate LACtate tate LACtate L LACtate tate LACtate L AC ACtate LACtate LACtate LAC LACtate tate LACtate L LACtate LACtate AC LACtate LACtate tate LACtate L LACtate ACtate LACtate tate LACtate LACtate LAC LAC LACtate LACtate LACtate tate LACtate L LACtate tate LACtate L LAC AC AC LACtate LACtate LACtate tate LACtate tate LACtate L LACtate tate LACtate L AC AC...
Open the catalog to page 4Multi-Parameter Meter Multi-Parameter Meter XPER TECHNOLOGY ‧Strip expiry date reminder ‧Before / After meal (AC/PC) presettable ‧Strip ejector ‧Before / After meal (AC/PC) presettable ‧Before / After meal (AC/PC) presettable ‧Individual target range ‧Strip expiry date reminder ‧Strip expiry date reminder Blue: Strip guiding light ‧Strip ejector ‧Strip ejector Green: Within target range ‧Strip light ‧Strip light
Open the catalog to page 5Multi-Parameter Meter 2+2 Technology TaiDoc patented the 2 + 2 (2 enzymes plus 2 signals) technology, which uses two different wells on the strips to detect HCT value by AC signal and glucose value by DC signal. ‧Enzyme: GDH-FAD ‧Sample size: 1.0 μL ‧Reaction time: 5 seconds TD-4143 ‧HCT range: 0 % – 70 % ‧Glucose range: 10 – 700 mg/dL TD-4140 ‧Before / After meal (AC/PC) presettable • Before / After meal (AC/PC) presettable ‧Before / After meal (AC/PC) presettable • Strip expiry date reminder ‧Strip expiry date reminder • Strip ejector ‧Strip ejector ‧Strip expiry date reminder ‧ProCheck...
Open the catalog to page 6B lood G lu c os e Mo n i t o r i n g S ys t e m s TaiDoc has developed 5 generations of test strip with different level and fulfils the accuracy requirements of ISO 15197 : 2013 & EN ISO 15197 : 2015. EF ( Electricity Fractionation ) technology utilize the negative charge characteristic on cell surface to separate blood cells from plasma for further estimation of hematocrit value. XPER Tech. Reaction Time (Seconds) after applying blood sample. Positive and negative charge will be created Measurement Range (mmol/L) Blood cells will be attracted to positive electrode. Hematocrit Range (%) •...
Open the catalog to page 7GDH-FAD, Glucose Meter ‧Reaction time: 5 seconds ‧Reaction time: 5 seconds ‧Reaction time: 6 seconds ‧Reaction time: 5 seconds ‧Reaction time: 6 seconds ‧Glucose range: 20 – 650 mg/dL ‧Before / After meal (AC/PC) presettable ‧Glucose range: 20 – 600 mg/dL ‧Glucose range: 20 – 650 mg/dL ‧Glucose range: 20 – 600 mg/dL ‧Glucose range: 20 – 650 mg/dL ‧Individual target range ‧Before / After meal(AC/PC) / ‧Before / After meal (AC/PC) ‧Before / After meal (AC/PC) ‧Before / After meal (AC/PC) Level 2: Out of target range Level 3: Within target range Level 4: Out of target range ‧Strip ejector...
Open the catalog to page 8TD-4277 ‧Sample size: 0.5 μL ‧Reaction time: 5 seconds ‧HCT range: 35 % – 60 % ‧Glucose range: 20 – 600 mg/dL ‧Before / After meal (AC/PC) presettable ‧Strip ejector ‧Strip light • Reaction time: 5 seconds • Reaction time: 7 seconds • Reaction time: 7 seconds • Glucose range: 20 - 600 mg/dL • Glucose range: 20 – 600 mg/dL • Glucose range: 20 – 600 mg/dL • Before / After meal (AC/PC) • Before / After meal (AC/PC) GDH-FAD, Glucose Meter
Open the catalog to page 9Glucose Meter Ketone Meter ‧Enzyme: GDH-FAD All-In-One Analyzer ‧Embedded Thermal Printer ‧Reaction time: 5 seconds ‧Reaction time: 10 seconds Simple Operation ‧Graphical User Interface ‧Reaction time: ≦ 6 mins ‧Glucose range: 10 – 600 mg/dL ‧Ketone range: 0.1 – 8.0 mmol/L ‧Fully Automatic Operation, ‧Barcode scanner ‧Barcode scanner ‧Memory capacity: ‧Memory capacity: or EDTA venous blood ‧Precision: CV < 5 % ‧Display unit: Percentage (%) or mmol/mol ‧Memory capacity: 10,000 results Reducing Human Error ‧Sample type: Whole blood - Fingertips capillary Docking Station: ‧Wireless charging in...
Open the catalog to page 10Lancing Device ‧Twist-release design ‧Loading indicator ‧6 level depth selection ‧9 Level depth selection ‧Five different size ‧Five depth settings (1.2 - 2.4 mm) ‧Lancet ejection ‧Lancet ejection ‧Lancet automatic retraction ‧Lancet automatic retraction ‧Lancet automatic retraction • Compatible with insulin pens in market • Obvious observation of use status • Easy self-disable
Open the catalog to page 11Blood Glucose • Enzyme: GDH-FAD • Method: Colorimetric • Reaction time: 5 seconds • Reaction time: 5 seconds • Reaction time: 180 seconds • Calcium range: 0.5 – 3.0 mmol/L • Glucose range: 10 – 600 mg/dL • Ketone range: 0.1 – 8.0 mmol/L • Strip ejector • Individual code card for different animal
Open the catalog to page 12Medical Device TD-2300 • 5 Parameters-ECG, NIBP, SpO2, Ear Temperature and Blood Glucose measurement • Nellcor SatSeconds (TM) alarm management technology (WIFI) • Suitable for adult and pediatric patients • 7" TFT color LCD touch screen • Defibrillation proof Medical Device Vital Signs Monitor | Pulse Oximeter Blood Pressure Monitor | Thermometer | Nebulizer Ordering Information Model No. SPECIFICATION PARAMETER Blood Pressure, SpO2 Monitor, Ear Temperature Blood Glucose Blood Pressure, SpO2 Monitor, Ear Temperature Blood Glucose, ECG Monitor Blood Pressure, SpO2 Monitor, Ear Temperature...
Open the catalog to page 13All TaiDoc Technology catalogs and technical brochures
-
TD-5086
1 Pages
-
2022TaiDoc_ company profile
7 Pages
-
TD-3128
1 Pages
-
TD4235E
1 Pages
-
TD-4277C
1 Pages
-
TD-4183
1 Pages
-
TD-4216
2 Pages
-
TD-4266
1 Pages
-
Procheck Smart
1 Pages
-
Procheck Witty
1 Pages
-
TD-4268
3 Pages
-
TD-5083
1 Pages
-
TD-5052
1 Pages
-
TD-3261
2 Pages
-
TD-4141
1 Pages
-
TD-4206A
5 Pages
-
TD-2300
5 Pages
-
TD-2300
5 Pages
-
TD-1242
1 Pages
-
TD-8255
1 Pages
-
TD-4277
1 Pages
-
TD-4206
2 Pages
-
TD-4280
1 Pages
-
TD-4611 HbA1c auto analyzer
2 Pages
-
TD-4258C
1 Pages
-
TD-4258E
1 Pages
-
TD-5010
2 Pages
-
TD-5011
2 Pages
-
TD-5053
1 Pages
-
TD-5220
1 Pages
-
TD-8201
2 Pages
-
TD-1035
1 Pages
-
TD-1107
3 Pages
-
TD-7013
1 Pages
-
TD-7014
2 Pages
-
TD-3140
2 Pages
-
TD-3124
1 Pages
-
TD-3127
1 Pages
-
TD-2555
1 Pages