Quattro-Sentinel-Specification
2Pages

{{requestButtons}}

Catalog excerpts

Quattro-Sentinel-Specification - 1

QUATTRO® Sentinel mattress replacement system specification • CHOICE OF THERAPY MODE: ACTIVE MODE to provide 1-in-4 cell cycle active therapy or CONTINUOUS LOW PRESSURE THERAPY MODE provides reactive therapy • EXTRA DURABLE air cells constructed from reinforced PU coated nylon for extra strength and durability • ODS™ (ortho-differential support) cell design provides optimal comfort and support for varying body shapes and sizes • AUTOsupport™ automatically adjusts pressure within each of the cells throughout the cycle so that support, posture and therapy are constantly maintained at optimum levels • MAXIMUM INFLATION inflates the mattress to maximum static pressure for 15 minutes before returning to previous therapy mode • COMFORT CONTROL adjustable in either therapy mode to help patient compliance • REMOVABLE SIDE BOLSTERS ideal for use with width-retractable beds to allow easy movement of complete bed system with patient in-situ • AUDIBLE AND VISUAL ALERTS indicate current operation status / fault conditions • AUTOLOCK feature prevents inadvertant button operation • PHASE FLOW™ pressure control pump operates on demand only, reducing power consumption, noise and extending service life • CPR FUNCTION for simple and effective rapid deflation to enable CPR procedures • TRANSPORT FACILITY allows unpowered support of the patient for up to 12 hours • MULTI-STRETCH COVER is waterproof and moisture-vapour permeable with welded seams and can be removed for laundering • LOW AIR-LOSS feature, where air is released and circulated beneath the mattress cover, helps to reduce humidity and manage the skin ‘microclimate’ between the patient and the support surface • ERGONOMIC DESIGN SOLUTIONS including antikink umbilical, non-tear mattress anchoring straps and cable management, together with integrated power unit carry handle and adjustable hanging brackets • MODULAR CONSTRUCTION enables simple repair/ service on site for minimum downtime • 370 KG (58 STONE) pa

Open the catalog to page 1
Quattro-Sentinel-Specification - 2

QUATTRO® Sentinel technical data Power Unit Length Height Depth Weight Mode of Operation Alternating Cycle Time Ingress Protection Rating Mains Cable Electricity Supply Rated Input Fuse Rating Noise Level 335 mm 233 mm 165 mm 3.4 kg 1-in-4 cell cycle (Active therapy) or Continuous Low Pressure (Reactive therapy) 16 mins IP21 5 metres 230V~50Hz 9.4 VA T500mA 250V HRC (ceramic) 5 x 20 mm 33.5 dBa Width* 1200 mm (860 mm without bolsters) Base tray: Woven nylon 940 DTEX PU coated both sides Inner Construction Materials Base layer and side bolsters: CMHR foam Cells: Reinforced PU coated nylon...

Open the catalog to page 2

All Talley Group Limited catalogs and technical brochures

  1. ATTIVO™

    2 Pages

  2. SYNCHRO™

    3 Pages

  3. ATTIVO

    2 Pages

  4. SYNCHRO™

    3 Pages

Archived catalogs

  1. QUATTRO PLUS

    1 Pages