Overview: The document outlines the features and benefits of the TBH Health series, focusing on the InLine filter technology designed for air filtration in medical environments. It emphasizes the importance of clean air for health and safety in treatment rooms, particularly during laser procedures.
InLine Filter Features: The InLine filter is developed for optimal air capture efficiency, reducing internal soiling and maintenance costs. It is made from high-tech medical-grade polycarbonate, stable at high temperatures, and resistant to disinfectants and cleaners. The filter is designed for easy cleaning and replacement.
Hygiene and Maintenance: The TBH hygiene concept recommends changing the InLine filter daily and the HEPA-main filter every six months. Proper cleaning and disinfection are crucial to prevent virus and bacteria transmission.
Extraction During Laser Treatments: Extraction systems are essential during laser treatments to protect against airborne particles. The document highlights the risks of harmful gases and the importance of correctly adjusted extraction systems to minimize infection risks.
TBH Health Models: The document describes three models: TBH Health Basic, TBH Health Pro, and TBH Health Pro Silence, each with different specifications for air volume flow, motor output, and noise levels. The Pro and Pro Silence models feature brushless motors for daily use.
Technical Specifications: Detailed technical data for each model is provided, including dimensions, weight, and motor specifications. The document also includes ordering information for systems and replacement filters.
Additional Features: The systems offer electronic features such as differential pressure indicators, easy filter changes, and optional foot switches for convenience. A warning system alerts users when filter saturation reaches 75%.
See more

Catalog excerpts

Health-Series-1

FILTER / EXTRACTION / ENVIRONMENTAL - // TECHNOLOGY Health series - Export VN2506 TRIPLE PROTECTION FOR // PEOPLE / ENVIRONMENT / MACHINERY

 Open the catalog to page 1
Health-Series-2

The patented InLine filter • • • • • • The InLine filter was developed especially for your applications and needs. Fewer cases of illness thanks to clean air in the treatment room. Optimal capture efficiency. Minimizes internal soiling of the extraction arm. Reduces cleaning effort and maintenance costs. Extends the service life of high-tech main filter. Localized capture is possible closer to the source Hygiene features of the InLine filter • • • • • High-tech medical grade polycarbonate Stable at high temperatures up to 121° C for autoclaving Improved resistance to disinfectants Improved resistance...

 Open the catalog to page 2
Health-Series-3

Tested and certified by the accredited, independent test laboratory CleanControlling Medical GmbH & Co. KG in Emmingen-Liptingen. To comply with the TBH hygiene concept, we recommend: Change the InLine filter only once a day Change the HEPA-main filter in the system only every six months Remove the protective grid and clean it in the thermal disinfector. Clean and replace the InLine filter Remove the InLine filter and fit a new InLine filter. Securely package the used InLine filter in a sealed, tear-proof bag and discard it. Tip Only effective extraction and filtration in combination with cleaning...

 Open the catalog to page 3
Health-Series-4

Reasons for extraction during laser treatments About Dr. Helmut Hahn: He is a dermatologist and partner at the Berchtesgaden Skin & Laser Center and conference president of the DDL Congress. In the video, he explains why professional associations require the use of extraction systems to protect against airborne particles. Tool-free filter change in the system Fast and smooth change No specialized knowledge required Easy handling No tools required Adsorption of gaseous substances • • Adsorption of gaseous substances with activated carbon granulate (physical adsorption) Broad spectrum of gases...

 Open the catalog to page 4
Health-Series-5

• InLine filter captures particles/ bacteria/ aerosols. • Protects the extraction arm from contamination. • HEPA particle filter ensures separation efficiency. • Activated carbon filters gases/odors. • HEPA particle filter H13 ensures separation efficiency. • Activated carbon filters gases/odors. Basic model at the best price Suitable for occasional use: Brushed motor (less than one hour of operation per day) Warranty: 600 operating hours or 2 years Compact model with a more powerful motor Suitable for daily use: Brushless motor (more than one operating hour per day). Warranty: 10,000 operating...

 Open the catalog to page 5
Health-Series-6

TBH filter concept: Functional principle InLine filter captures particles/ bacteria/ aerosols. Protects the extraction arm from contamination. HEPA particle filter ensures separation efficiency. Activated carbon filters gases/odors Larger filter surface Lower follow-up costs for replacement filters: (HEPA particle filter and activated carbon can be replaced separately). HEPA particle filter H14 • Larger air volume and more performance • Suitable for daily use: Brushless motor (more than one operating hour per day). Warranty: 10,000 operating hours or 2 years System height without extraction arm...

 Open the catalog to page 6
Health-Series-7

Chirurgische Maske <0,1 pm Hazards in Dermatology Practices HARMFUL GASES /

 Open the catalog to page 7
Health-Series-8

Areas of application Removing lesions with laser During laser removal procedures, such as for warts or benign melanocytic dermatological lesions, extraction is required to prevent the inhalation of potentially infectious particles and to protect medical staff in their daily work. HPV risks Medical staff performing laser treatments in areas such as gynecology are at increased risk of HPV-related diseases such as laryngeal papillomatosis and oropharyngeal carcinoma. Correctly adjusted and positioned extraction is the most effective protective measure to minimize the risk of infection.

 Open the catalog to page 8
Health-Series-9

TBH Health Basic ^TBH’ Delivery scope • System incl. extraction arm 050 with InLine filter • Incl. filter equipment • Additional InLine filters (10 pieces) • Powerd cord

 Open the catalog to page 9
Health-Series-10

TBH Health Pro ^TBH’ Delivery scope • System incl. extraction arm 050 with InLine filter • Incl. filter equipment • Additional InLine filters (10 pieces) • Powerd cord

 Open the catalog to page 10
Health-Series-11

Ordering Data TBH Health Basic and Pro a The TBH Health Pro extraction and filtration systems are not classified as application parts under DIN EN 60601-1, as they are designed, and the extraction arm is positioned, to ensure that it does not make contact with the patient during intended use. To meet the stricter safety requirements in the medical field, testing according to DIN EN 62353 (VDE 0751-1) as required in DIN EN 60601-1 is possible.

 Open the catalog to page 11
Health-Series-12

Technical dataTBH Health Pro Silence Delivery scope System incl. console & extraction arm 075 with InLine filter Incl. filter equipment 4 wheels for mobile use Additional InLine filters (10 pieces) Powerd cord System height without extraction arm

 Open the catalog to page 12
Health-Series-13

Ordering Data TBH Health Pro Silence DESIGNATION TBH Health Pro Silence 100-240V 50/60Hz REPLACEMENT FILTERS InLine filter (pack of 105) InLine filter (pack of 50) HEPA particle filter H14 Activated carbon filter Note! The TBH Health Pro extraction and filtration systems are not classified as application parts under DIN EN 60601-1, as they are designed, and the extraction arm is positioned, to ensure that it does not make contact with the patient during intended use. To meet the stricter safety requirements in the medical field, testing according to DIN EN 62353 (VDE 0751-1) as required in DIN...

 Open the catalog to page 13
Health-Series-15

Optional capture elements for different areas of application Electronic features and display functions Differential pressure indicator for monitoring filter saturation Easy and clean filter change from above Optimum convenience through use of the optional foot switch Warning when the filter saturation reaches 75% Always full control over the system A Start/Stop button B Manual speed rotation regulation 1 Saturated filter indicator 2 System status indicator 3 Speed setting indicator/operating hours counter 4 Temperature and turbine status indicator 5 Filter status indicator

 Open the catalog to page 15

All TBH® GmbH catalogs and technical brochures

  1. LN 200

    28  Pages

  2. FP 200

    20  Pages

  3. DT 100-DT 150

    12  Pages

  4. GL-Series

    20  Pages

  5. CR-Series

    20  Pages

  6. FP 200 ATEX

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.