Think Coag Think Tcoag Catalogue Your Coagulation Company
Open the catalog to page 1TriniCLOT™ Routine Reagents Factor Deficient Plasmas 7 TriniLIA™ D-Dimer TriniCLOT™ Speciality Reagents TriniCLOT™ Lupus Screen and Confirm 9 TriniCHROM™ Speciality Reagents TriniCAL™ Reference Plasmas TriniCAL™ Reference Plasma 11 Tcoag Control offering 13 TriniLIZE™ ELISA based Assays TriniLIZE™ Stabilyte tubes 15 TriniLIZE™ tPA/PAl Depleted Plasma RUO 15 TriniLIZE™ PAI Activity Control RUO 15 Fibrinolysis Reference Plasma RUO 15 Platelet Aggregation Reagents Ristocetin Cofactor Assay 16 TriniCHECK™ Controls iTHTl TriniCHECK™ Controls
Open the catalog to page 3TriniCLOT™ Routine Reagents TriniLIA™ D-Dimer TriniCLOT™ Speciality Reagents TriniCHROM™ Speciality Reagents TriniCHECK™ Controls TriniCAL™ Reference Plasmas TriniLIZE™ ELISA based Assays Platelet Agregation Reagents
Open the catalog to page 5TriniCLOTTM Routine Reagents PT The PT test is commonly used to monitor oral anticoagulants, factor deciencies and for general preoperative screening. An abnormal or extended PT test usually indicates a deciency in one or more of the factors in the extrinsic or common pathway of blood coagulation. TriniCLOTTM PT Reagents are lyophilised thromboplastins from either rabbit or human sources which guarantee consistently accurate results. Convenient and reliable, TriniCLOTTM PT Reagents are the quality PT reagents of choice for your haemostasis laboratory. TriniCLOTTM PT HTF (HTF = Human Tissue Factor)...
Open the catalog to page 6aPTT The Activated Partial Thromboplastin Time (APTT) assay is a universally accepted screening procedure used to detect abnormalities in the intrinsic coagulation system. In addition, it can be used to detect lupus anticoagulants and when monitoring heparin therapy. TriniCLOTTM aPTT S and TriniCLOTTM aPTT HS are liquid, ready to use, aPTT reagents intended for screening for deciencies of the intrinsic coagulation pathway. These reagents contain puried phospholipids and a particulate activator (micronized silica), which are stabilized in an appropriate buffer. TriniCLOTTM Automated aPTT is a...
Open the catalog to page 7TriniCLOTTM Routine Reagents Fibrinogen TriniCLOTTM Fibrinogen is intended for quantitative determination of brinogen in plasma. TriniCLOTTM Fibrinogen utilizes the Clauss method for brinogen determination. An excess of thrombin is used to convert brinogen to brin in diluted plasma such that the rate of reaction is a function of brinogen concentration. • Convenient format: TriniCLOTTM Fibrinogen is provided in a kit format and as individual components. • Wide working range to address different clinical contexts (e.g. 0.45g/L – 14 g/L in Optical mode using re-dilution) • Extended on board and...
Open the catalog to page 8Factor Decient plasmas A full suite of immuno-depleted TriniCLOTTM Factor Decient Plasmas for all the extrinsic and intrinsic factors is provided. • TriniCLOTTM Factor VIII may also be used as a negative control in Von Willebrand Factor assays. • Used with TriniCHECKTM Control 1 (T4101), TriniCHECKTM Abnormal Control (T4104) and TriniCALTM Reference Plasma (T5102). PRODUCT NAME TriniCLOTTM Factor II, V, VII or X Decient Human Plasma are intended for the quantitative determination of extrinsic factors in human plasma by clotting assay. TriniCLOTTM Factor VIII, IX, XI or XII Decient Human Plasma...
Open the catalog to page 9D-Dimer Elevated levels of D-Dimer are associated with thrombotic disorders, such as Deep Venous Thrombosis (DVT), Pulmonary Embolism (PE) and Disseminated Intravascular Coagulation (DIC) as well as other conditions, such as cancer. The presence of elevated D-Dimer levels is not sufcient for the diagnosis of a thrombotic disorder, but the absence of elevated D-Dimer levels when used with the appropriate algorithm may be used to rule out the presence of DVT and PE. PART NUMBER PACKAGING PACKAGIN STABILITY Reagent: 14 days at 2-8°C Reaction Buffer: 14 days at 2-8°C Diluent: 14 days at 2-8°C TriniCAL...
Open the catalog to page 10TriniCLOTTM Speciality Reagents NEW TriniCLOTTM PC II PART NUMBER The TriniCLOT PC II kit is intended for the quantitative measurement of the functional protein C level based on the prolongation of the activated partial thromboplastin time (APTT). PRODUCT NAME Reagent 1 (TriniCLOTTM PC Def Plasma): 3 x 1mL 8 hours on board stability Reagent 2 (TriniCLOTTM PC Activator): 3 x 1mL 8 hours on board stability PRODUCT NAME In this assay, Protein C is activated in the presence of the specic activator extracted from Agkistrodon c. contortrix venom. The resulting activated protein C inhibits the factors...
Open the catalog to page 11TriniCHROMTM Speciality Reagents TriniCHROMTM Antithrombin IIa and TriniCHROMTM Antithrombin Xa PART NUMBER TriniCHROMTM Antithrombin IIa and TriniCHROMTM Antithrombin Xa are intended for the quantitative determination of AT activity in human plasma by chromogenic assay. AT is the major inhibitor of plasma thrombin and Factor Xa. It is also an important inhibitor of activated Factors IXa, XIa, and XIIa. The inhibitory activity of AT towards thrombin is greatly increased (2–3 orders of magnitude) in the presence of heparin. TriniCHROMTM Antithrombin IIa and TriniCHROMTM Antithrombin Xa utilize...
Open the catalog to page 12TriniCALTM Reference Plasmas TriniCALTM Reference control plasmas are citrated freeze-dried human plasmas which guarantee consistently accurate results. PART NUMBER PART NUMBER PRODUCT NAME TriniCALTM INR & Quick Monitoring of coumadin or coumadin-like Oral Anticoagulant Therapy (OAT) is generally performed with the Prothrombin Time (PT) test. When used for monitoring OAT, the World Health Organization recommends normalizing and reporting the results of the PT test as an INR rather than seconds. The PT may also be reported in a normalized format as a Percent Activity. TriniCALTM INR & Quick Calibrator...
Open the catalog to page 13TriniCHECKTM control plasmas TriniCHECKTM control plasmas are pooled citrated freeze-dried human plasmas which guarantee consistently accurate results. Convenient and reliable, TriniCHECKTM plasmas are the Quality controls of choice for your haemostasis laboratory. • • • • Freeze-dried human plasmas guarantee reliable and accurate results. Both Assayed and Unassayed presentation. Convenient pack sizes. Consistent value assignments from lot to lot. PART NUMBER PRODUCT NAME TriniCHECKTM Abnormal Control TriniCHECKTM Lupus Positive Control 8 hours on board stability 8 hours on board stability Speciality...
Open the catalog to page 1424 Pages