AD-101

AD-101

AD-101

Product catalog summary
Overview: The AD-101 Air Bubble Detector by TE Connectivity is designed for non-invasive continuous monitoring of fluids to detect air bubbles, crucial in applications like infusion pumps and blood flow monitoring. It uses ultrasonic technology to identify breaks in liquid flow.
Features:
  • Detects bubbles as small as 70% of the tubing's inner diameter.
  • Customizable to fit tubes or pipes ranging from 3 mm to 10 mm.
  • Non-invasive design maintains sterility and fluid compatibility.
  • High immunity to electromagnetic and radio frequency interference.
  • No need for an acoustic coupling agent.
  • Includes integral electronics with power-on and continuous self-diagnostic tests.
Applications: Suitable for use in infusion pumps, apheresis, biotech/DNA analysis, blood processing, immunoassays, chemical analysis, hemodialysis, in-vivo gas detection, hydroponics, smart farming, and food processing.
Operating Parameters & Specifications:
  • Temperature range: 0°C to 40°C.
  • Response time: 0.2 milliseconds.
  • Input voltage: 5VDC to 24VDC.
  • Output: 3.3 V TTL Logic.
Technical Specifications:
  • Material: ABS/PC plastic blend, UL 94 V-2 rated.
  • Cable: 4 conductor 28AWG, 350mm long, UL Style Number 2725.
  • Pin Out: Black (GND), White (Output), Yellow (Self-test), Red (5 - 24 VDC).
Part Numbers:
  • 071-06403: AD-101 compact ABD assembly 4MM.
  • 071-06402: AD-101 compact ABD assembly 6MM.
Disclaimer: TE Connectivity provides this information as reliable but does not guarantee its accuracy or completeness. Users should evaluate the product's suitability for specific applications.
See more

Catalog excerpts

AD-101-1

AD-101 Air Bubble Detector Bubble detection is critical in applications such as infusion pumps, hemodialysis and blood flow monitoring. TE Connectivity (TE) has developed a new compact AD-101 Air Bubble Detector (ABD) for non-invasive continuous monitoring of fluid for air bubble detection. Using ultrasonic technology the AD-101 sensor is capable of Operating Parameters & Specifications positively identifying the presence of a break in flow of any type of liquid.  Sensor can be customized to fit tube or pipe  Detects bubble size as small as 70% of tubing inner diameter  Tubing size from 3 mm to 10 mm  Non-invasive design eliminates sterility and fluid compatibility concerns  High noise immunity to EMI/RFI  Acoustic coupling agent not required  Integral electronics  Power-on and continuous self-diagnostic tests to confirm functionality  Apheresis/Auto-transfusion  Blood Processing  Immunoassay  IN-VIVO Detection of Gas  Smart

 Open the catalog to page 1
AD-101-2

Dimensions Schematic White = Output Sensor Output 3.3V TTL, Low When Liquid Present, High When Bubble Present Self-Test Output Response Time Temp. Range Bubble Size Yellow = Self-test output, 3.3V TTL, High When Pass, Low When Fault 0.22 Milliseconds 0 to 40°C Smallest bubble detected =70% of tubing I.D. ABS/PC (55/45) Plastic Blend, Injection Molded Parts, UL 94 V-2 Rated 4 Conductor 28AWG, 350mm Long UL Style Number 2725 Integral Description AD-101 compact ABD assembly 4MM AD-101 compact ABD assembly 6MM NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity Company Tel 800-522-06752...

 Open the catalog to page 2