HydroSpeed™-1

SPEED AND CONTROL FOR OPTIMIZED WASHING OF CELLS, BEADS AND ELISAS

 Open the catalog to page 1
HydroSpeed™-2

Are you washing away your cells? Loosely adherent cell lines, such as P815 and HEK293, are commonly used for a wide range of research applications, but are challenging to wash for typical plate washers. Excessive dispense speeds can cause detachment of cells and holes in the cell layer. Coupled with loss of cells during poorly controlled aspiration, this can lead to reproducibility issues and high CVs, resulting in failed experiments, repeat testing and a loss of productivity. Cell loss due to aggressive wash conditions Schematic picture showing a damaged cell layer in a well Failed results leading...

 Open the catalog to page 2
HydroSpeed™-3

Are your magnetic beads being washed away? Multiplexed assays using magnetic beads are becoming increasingly popular for a variety of applications, but achieving good wash results without losing beads remains a challenge. Automated washing protocols often suffer from low bead recovery rates due to insufficient bead settling by weak magnets. Poor control of aspiration parameters also makes it difficult to achieve low residual liquid volumes without significant loss of beads, leading to inconsistent results and high CV values. ■ri.r^nco oyoc Loss of magnetic beads due to insufficient bead settling...

 Open the catalog to page 3
HydroSpeed™-4

Are you suffering from needle clogging during ELISA washing? Automated ELISA processing using a microplate washer is now a routine task for many laboratories, yet crystallization of wash buffer within the aspiration/dispense needles remains a common problem. This causes clogging of the needles while the washer is idle between plates, and can lead to loss of entire runs as a result of overflowing wells. Cleaning of wash heads is laborious and time consuming, and can significantly affect productivity if washers are integrated into automated liquid handling systems. Picture showing blocked dispense...

 Open the catalog to page 4
HydroSpeed™-5

Fast, reliable washing in96- and 384-well formats 21 CFR Part 111 ON-BOARD CONTROL AT YOUR FINGERTIPS Easy-to-use touchscreen interface allows full on-board operation, eliminating the need for an external PC to define wash programs and plate parameters. • New plate assistant function for easy teaching of new plates • Pre-defined plate library, with typical plate parameter settings for commonly used 96- and 384-well plates, allows rapid setup of new wash protocols • 96 indexing wash head allows HydroSpeed to be used for washing both 96- and 384-well plates, without swapping wash heads • 96 indexing...

 Open the catalog to page 5
HydroSpeed™-6

Specifications General Number of disp. channels Wash head types 96HT for high speed washing in 96-well format 384HT for high speed washing in 384-well format 96-indexing for flexible washing in 96- and 384-well formats Wash volume, 96-well format Wash volume, 384-well format Performance Wash times, 96-well format 15 secs for 1-cycle wash incl. crosswise asp. step (disp. vol: 300 µl/well, disp. rate: 5, asp. rate: 5, 96HT head) Wash times, 384-well format 15 secs for 1-cycle wash incl. asp. step (disp. vol: 100 µl/well, disp. rate: 5, asp. rate: 5, 384HT head) Dispense accuracy @ 300 µl, 96-well...

 Open the catalog to page 6