09/2011 • Coordination : Serge Itzkowitch • Création : • Photographies : Fréderic Marigaux • Impression VACUUM REGULATORS
Open the catalog to page 1DIRECT PRDBES AFNOR direct probe OHMEDA direct probes NORDIC direct probe Other standards available upon request.
Open the catalog to page 3RVTM3 The vacuum regulator is used to measure and to adjust the vacuum level within the context of surgical and medical suctions. It enables to drain substances out of the patient’s body during surgical procedures. The vacuum regulator should be connected to a vacuum source on the wall either using a direct probe or a rail mounting system. It is the primary device of a suction system. It should be associated with a collection jar and a suction hose. Main technical features: Active medical device of class IIa. In compliance with the EN ISO 10079-3: 2009 standard. • onnections to the wall outlet:...
Open the catalog to page 4VACUUM REGULATORS SUCTION Patented model Compact, strong and ergonomic device. Vacuum gauge manually adjustable from -45° to +45° for a better visibility. Protected by a plastic housing. ON/OFF switch-button providing a quick restoration of the preadjusted vacuum level. Central regulation knob with a free rotation at the end of the course (impossible blocking). Quick adjustment: 2.5 turns are enough to reach the maximum vacuum level. Fixing of the safety jar by an easy-click rotation. Rotation of the safety jar to avoid any pinch of the tubing. 100 ml safety jar made of polycarbonate, unbreakable,...
Open the catalog to page 5VACUUM REGULATORS RV01 RVTM3 vacuum regulator 0-600 mbar, yellow, with 100 ml safety jar and DIN direct probe. RV02 RVTM3 vacuum regulator 0-400 mmHg, grey, with 100 ml safety jar and BS direct probe. RV03 RVTM3 vacuum regulator 0-1000 mbar, yellow, with 100 ml safety jar and AFNOR complete rail mounting system.
Open the catalog to page 6RV04 RVTM3 Twin vacuum regulator 600-1000 mbar, yellow, mounted with 100 ml safety jars and AFNOR direct probe. VACUUM REGULATORS RV05 RVTM3 vacuum regulator 0-250 mbar, grey, with integrated outlet tubing nipple and OHMEDA direct probe. RV06 Complete suction system composed of: One RVTM3 vacuum regulator mounted with AFNOR complete rail mounting system, one 2 L collection jar, one catheter holder 1 tube, silicone suction tubing and one vacuum–stop.
Open the catalog to page 7RVTM3 also available with mmHg gauge on request. Please contact us for other configurations.
Open the catalog to page 8Available upon request only. RVTM3 also available with mmHg gauge on request. Please contact us for other configurations.
Open the catalog to page 9RTVM3 also available with mmHg gauge on request. Please contact us for other configurations.
Open the catalog to page 10safety jars with antibacterial paper filter (former models) RV07 150 ml safety jar with antibacterial paper filter in the cover. Ref: 11738 RV08 500 ml safety jar with antibacterial paper filter in the cover. Ref: 11733 RV09 RTVM3 vacuum regulator 0-1000 mbar yellow, mounted with 500 ml safety jar. RV10 Box of 100 single-use antibacterial paper filters. Ref: 11818
Open the catalog to page 11VACUUM REGULATORS Description VACUUM GAUGE WITH HOUSING 0-1000 mbar vacuum gauge, yellow* 0- 600 mbar vacuum gauge, yellow* 0- 250 mbar vacuum gauge, yellow* 0- 760 mmHg vacuum gauge, yellow* 0- 400 mmHg vacuum gauge, yellow* BODY RVTM3 body 0-1000/0-600 mbar – 0-760/400 mmHg with ON/OFF switch-button RVTM3 body 0-250 mbar with ON/OFF switch-button Complete ON/OFF switch-button Batch of 3 gaskets for ON/OFF switch-button Gasket for vacuum gauge Outlet gasket Back housing, yellow* Screw for back housing 0-1000 mbar complete cover, yellow* 0- 600 mbar complete cover, yellow* 0- 250 mbar complete...
Open the catalog to page 12VACUUM REGULATORS 100 ML SAFETY JAR WITH SINGLE-USE ANTIBACTERIAL PLASTIC FILTER UP-FRONT Easy and quick replacement of the filter. It is useless to sterilize the safety jar after each filter replacement as the safety jar is protected by the filter at the inlet. Technical and financial advantages of the antibacterial plastic filter up-front: H ygiene: very hygienic system limiting the contamination risk of the device and the vacuum pipeline network. The plastic housing avoids any direct contact with the contaminated filter. V isibility of the contamination level: thanks to its vertical up-front...
Open the catalog to page 13101, rue Vailbnt Couturier B.P. 46 F-931 36 NOISY-LE-SEC CEDEX France