GIERTH TR 90/30
2Pages

{{requestButtons}}

Catalog excerpts

GIERTH TR 90/30 - 1

Product Information GIERTH TR 90/30 Maximum power - minimum size and weight - Especially recommended for the requirements of the equine practice Brief description: Powerful high frequency X-ray unit with full wave inverter system Only 6500 g at reduced size Integrated DR interfaces Low line voltage mode ensures reliable performance between 160 - 260 V GIERTH TR technology meets the radiation protection standards of tomorrow already today Innovative impact resistant construction reduces the risk of X-ray tube damage e.g. after a horse kick Activation of collimator light by hand switch Dual laser pointer for indication of central beam and SID eliminates guesswork in positioning Collimator with scale for presetting the light field format Digital and setting display of mAs, sec., kV LED display “X-RAY”, “READY”, “ERROR”, “Low Voltage” 5 memory buttons Acoustic and optical trigger signal Tape measure for SID Aluminium casing with reenforced edging Construction: Monobloc high frequency generator with full bridge inverter system, impact resistant construction + serial DR interface Output in 2-kV steps: 40-60 kV = 30 mA (max.) 62-70 kV = 25 mA (max.) 72-80 kV = 20 mA (max.) 82-90 kV = 15 mA (max.) X-ray tube: XDT-F80 Focus: 0.8 mm x 0.8 mm Timer: digital, from 0.02-2.0 sec. Total filtration: 2.7 mm Al (incl. collimator) Inverter frequency: 100 kHz, full bridge inverter system OR Technology (Oehm und Rehbein GmbH), Neptunallee 7c, 18057 Rostock, Germany Tel. +49 381 36 600 600, info@or-technology.com, www.or-technology.com Line adjustment: automatic Line voltage : AC single phase, 130-260 V, 50/60 kHz,16 A Low line voltage mode Overload protection: for high frequency transformer and X-ray tube Power requirement: 1.8 kVA Dual laser Pointer: 2 x class IIIa laser diodes 12V DC Weight: 6.5 kg, incl. collimator and dual laser Dimensions: L 300 mm, W 188 mm, H 172 mm (without handle) - The newest generation of X-ray units weighing only 6500 g - Higher penetration power for animal radioscopy

Open the catalog to page 1
GIERTH TR 90/30 - 2

GIERTH TR 90/30 Maximum power - minimum size and weight Carrying case (incl.) Specifications subject to revision without notice The editor strives to impart correct and up to date information. The provided specifications are based on current knowledge and are subject to revision without notice. This brochure is subject to correction. The editor assumes no responsibility for the information being up to date, correct and complete. All furnished logos, pictures and graphics are property of the particular company and subject to copyright of the licensor. Use, dissemination, distribution or...

Open the catalog to page 2

All OR Technology - Oehm und Rehbein catalogs and technical brochures

  1. XenOR 43CL

    2 Pages

  2. XenOR 35CW

    2 Pages

  3. 4343F

    2 Pages

  4. Amadeo Z-DR

    7 Pages

  5. Chiro Tools

    4 Pages

  6. FLAATZ 560

    2 Pages

  7. FDX 4343R

    2 Pages

Archived catalogs

  1. Voxar 3DTM

    12 Pages

  2. MobileView

    2 Pages