INDIVIDUALLY VENTILATED CAGES
1 / 48Pages

Catalog excerpts

INDIVIDUALLY VENTILATED CAGES - 1

INDIVIDUALLY VENTILATED CAGES

Open the catalog to page 1
INDIVIDUALLY VENTILATED CAGES - 2

INDIVIDUALLY VENTILATED CAGES

Open the catalog to page 2
INDIVIDUALLY VENTILATED CAGES - 3

TECNIPLAST HAS BEEN INVOLVED FOR MORE THAN 60 YEARS IN THE FIELD OF LAB ANIMAL RESEARCH AND IN ITS INNOVATIONS TO ACHIEVE THE CHALLENGING GOALS SET BY THE SCIENTIFIC RESEARCH. THE ORIGINAL NEED TO HAVE JUST A “CONTAINER” FOR RODENTS HAS EVOLVED OVER TIME TO MEET THE NEED OF A 5 BLUE LINE NEXT & BLUE LINE RANGE OF PRACTICAL, SCIENTIFIC REQUIREMENTS. THESE BIO-EXCLUSION, SEPARATION OF SMALL GROUPS OF ANIMALS, SPACE SAVING, ERGONOMICS, PRACTICALITY OF USE, AND LAST BUT NOT LEAST, ANIMAL AND HUMAN WELFARE. COMPLIANCE WITH THESE CRITERIA IS ESSENTIAL IN ORDER TO AVOID GREEN LINE UNDESIRABLE...

Open the catalog to page 3
INDIVIDUALLY VENTILATED CAGES - 5

BLUE LINE NEXT & BLUE LINE FOR MICE SEALSAFE® NEXT FOR MICE SEALSAFE® NEXT FOR RATS SEALSAFE® NEXT THE SEALSAFE NEXT LINE HAS BEEN SPECIFICALLY DESIGNED TO PROVIDE THE OPTIMUM BALANCE BETWEEN DENSITY, ERGONOMICS, ANIMAL WELL-BEING AND CAPITAL EXPENDITURE. BLUE LINE NEXT COMES FROM THE RE-STYLING OF THE TECNIPLAST SEALSAFE IVC LINE PRESERVING ALL THE KEY FACTORS BEYOND THE SUCCESS OF THAT SYSTEM.

Open the catalog to page 5
INDIVIDUALLY VENTILATED CAGES - 6

BLUE LINE NEXT A WIDE RANGE OF CAGES, OFFERING MAXIMUM FLEXIBILITY WITH THE WELL-KNOWN TECNIPLAST QUALITY ANIMAL WELFARE ■ Air inlet and outlet valves placed in the top: no air drafts at animal level, avoiding risk of stress and heat loss, as reported in the scientific literature ■ Stand-alone Air Handling Unit: Easy, Smart and Sky Flow provide safe ventilation without transmitting vibrations to the rack, ensuring standardization of the experiment. The system is independently certified by TÜV MAX AIR SPEED AT ANIMAL LEVEL: 0.05 M/SEC PROTECTION FOR OPERATORS AND ANIMALS ■ Microbiological...

Open the catalog to page 6
INDIVIDUALLY VENTILATED CAGES - 7

1291H - TYPE III HIGH CAGE FOR RATS OR ADULT MICE 1285L - TYPE II LONG CAGE FOR MICE 1145T - SHOE-BOX CAGE FOR MICE MULTILINKING CAPABILITY: MAXIMIZED DENSITY LOW RUNNING COSTS ■ Stand-alone air handling unit can manage up to 4 single-sided racks: energy saving with lower maintenance costs ■ ECM DC-Blowers means low power consumption and less maintenance ■ Quick daily check, easy access to the cage and quicker bottle change mean low labour costs

Open the catalog to page 7
INDIVIDUALLY VENTILATED CAGES - 8

BLUE LINE NEXT · IVCs FOR MICE 81 cages (9w x 9h), single sided 126 cages (7w x 9h), double sided 144 cages (8w x 9h), double sided 72 cages (8w x 9h), single sided 63 cages (7w x 9h), single sided 162 cages (9w x 9h), double sided

Open the catalog to page 8
INDIVIDUALLY VENTILATED CAGES - 9

72 cages (8w x 9h), single sided 108 cages (6w x 9h), double sided 126 cages (7w x 9h), double sided 63 cages (7w x 9h), single sided 54 cages (6w x 9h), single sided 144 cages (8w x 9h), double sided

Open the catalog to page 9
INDIVIDUALLY VENTILATED CAGES - 10

BLUE LINE NEXT · IVCs FOR RATS 30 cages (5w x 6h), single sided 24 cages (4w x 6h), single sided 36 cages (6w x 6h), single sided

Open the catalog to page 10
INDIVIDUALLY VENTILATED CAGES - 11

BLUE LINE · IVCs FOR RATS 15 cages (3w x 5h), single sided 20 cages (4w x 5h), single sided GUINEA PIGS CONFIGURATION 11

Open the catalog to page 11
INDIVIDUALLY VENTILATED CAGES - 13

GREEN LINE FOR MICE SEALSAFE® PLUS FOR RATS SEALSAFE® PLUS FOR RATS SEALSAFE® PLUS THE SEALSAFE PLUS, ALSO KNOWN AS THE GREEN LINE, IS THE WORLDWIDE RECOGNIZED IVC STANDARD. IT PROVIDES THE BEST PERFORMANCE IN TERMS OF PROTECTION, ERGONOMICS AND DENSITY. DGM IS THE LATEST DIGITAL-READY IVC RACK THAT GIVES YOU THE KEY TO ENTERING INTO THE FUTURE, BEING PREARRANGED FOR THE REVOLUTION OF THE INDUSTRY, THE DVC™.

Open the catalog to page 13
INDIVIDUALLY VENTILATED CAGES - 14

GREEN LINE The Sealsafe® PLUS range of IVC products features a PATENTED cage design, consisting of a soft silicone gasket that protrudes radially all around the cage base rim. The perfect sealing is simply achieved by placing the top on the cage body, through the radial interference between gasket and cage top. Consequently, the vertical compression (commonly provided by the use of latches) of the silicone gasket between cage base and top is not required: ■ no latches for the best ergonomics ■ no need for latches to achieve excellent containment and high protection PROTECTION FOR OPERATORS...

Open the catalog to page 14
INDIVIDUALLY VENTILATED CAGES - 15

ANIMAL WELFARE ■ Air inlet and outlet valves in the top: no air draft at animal level, avoiding risk of stress and heat loss, as reported in the scientific literature ■ Stand-alone Air Handling Unit: Easy, Smart, Sky and Wi Flow provide safe ventilation without transmitting vibrations to the rack, ensuring standardization of the experiment. The system is independently certified by TÜV ERGONOMICS ■ No latches for a faster cage change, while protection is always ensured by the patented cage sealing; ideal for Automation ■ Half length wire bar lid: easy access for a quicker cage change,...

Open the catalog to page 15
INDIVIDUALLY VENTILATED CAGES - 16

GREEN LINE · IVCs FOR MICE ■ DGM rack and GM500 cage have been designed in order to provide maximum visibility, improving the ease, the speed and the quality of daily room checks. 60 cages (6w x 10h), single sided 63 cages (7w x 9h), single sided 54 cages (6w x 9h), single sided 70 cages (7w x 10h), single sided 72 cages (8w x 9h), single sided 80 cages (8w x 10h), single sided 126 cages (7w x 9h), double sided 140 cages (7w x 10h), double sided 144 cages (8w x 9h), double sided UNI-HAND CAGE BODY 120 cages (6w x 10h), double sided 108 cages (6w x 9h), double sided 160 cages (8w x 10h),...

Open the catalog to page 16
INDIVIDUALLY VENTILATED CAGES - 17

DIGITAL READY THE NEW DGM RACK IS FULLY COMPATIBLE WITH STATE-OF-THE-ART REVOLUTIONARY TECHNOLOGIES SUCH AS: ■ DVCTM Digital Ventilated Cage - a revolutionary technology able to enhance standardization and reduce running costs through the optimization of the facility cage-related operations and management ■ Inventory Stand Alone Module (DVCTM-INVENTORY)- the unique TTHE BRAIN FOR YOUR CAGES system able to automatically perform accurate “Real Time Census”, occupancy and location of all your cages ■ Leak Detection System (LDS) - the smart system able to detect at the earliest stage any cage...

Open the catalog to page 17
INDIVIDUALLY VENTILATED CAGES - 18

GREEN LINE · IVCs FOR RATS 35 cages (5w x 7h), single sided 56 cages (4w x 7h), double sided ■ Seven-row rack under 2 meters high in a small footprint 28 cages (4w x 7h), single sided 70 cages (5w x 7h), double sided for maximized density: optimized floor area usage with consequent reduction of the facility running costs. LID FOR MICE WITH MOUSE LOFT CAGE DIVIDER GUINEA PIGS CONFIGURATION

Open the catalog to page 18

All Tecniplast catalogs and technical brochures

  1. TP_HOUSING_IVC

    52 Pages

  2. CLIMA_FLOW

    2 Pages

  3. TP_ARIA

    44 Pages

  4. IWT BHS

    20 Pages

  5. IWT AUTOMATION

    20 Pages

  6. IWT LOGISTICS

    20 Pages

  7. IWT DECON

    8 Pages