RPR – 100

RPR – 100

Product catalog summary
Intended Use: The Teco Diagnostics Rapid Plasma Reagin (RPR) set is designed to detect and quantify reagin antibodies in serum or plasma, primarily for diagnosing syphilis and other treponemal diseases. It may also show reactivity in individuals with other conditions.
Principle: The test identifies reagin antibodies produced in response to Treponema pallidum, the bacterium causing syphilis. A reactive sample will show black clumps on the test card, while a non-reactive sample will appear as a light-grey suspension.
Test Details:
  • Test Name: Rapid Plasma Reagin (RPR) Set (RPR – 100)
  • Number of Tests: 100 tests
  • Format: Liquid
  • Method: Agglutination Reaction
  • Testing Procedure: Manual
  • Storage Temperature: 2-8°C
Qualitative Results:
  • Reactive: Presence of large aggregates in the test circle.
  • Non-reactive: Smooth grey surface.
Limitations of Procedure: The test should not be used alone for diagnosis. Results must be considered alongside other clinical findings. False positives may occur in cases of drug abuse, lupus erythematosus, mononucleosis, leprosy, viral pneumonia, and post-smallpox vaccination. Plasma specimens older than 48 hours may yield inaccurate results.
Contact Information: Teco Diagnostics, 1268 N. Lakeview Avenue, Anaheim, CA 92807. Tel: 714-463-1111, Fax: 714-463-1169.
See more

Catalog excerpts

RPR – 100-1

Intended Use The Teco Diagnostics Rapid Plasma Reagin(RPR) set is a nontreponemal flocculation test that is used to detect and quantify reagin, an antibody present in serum or plasma from persons with syphilis or with other treponemal diseases. Occasionally individuals with other diseases or conditions may also be reactive in the nontreponemal tests. Principle Treponema pallidum, the etiologic agent responsible for syphilis produces at least two kinds of antibodies in human infections – trepenonemal antibodies and reagin antibodies. In the presence of the reagin antibody in the reactive sample, the RPR Antigen preparation will produce flocculation consisting of black clumps against the white background of the test card. By contrast, non-reactive samples will yield an even light-grey homogenous suspension. Test: Rapid Plasma Reagin (RPR) Set (RPR – 100) Number of Tests: 100 tests Format: Liquid Method: Agglutination Reaction Testing Procedure: Manual Storage Temperature: 2-8°C Qualitative Results: Reactive: Presence of large aggregates in the center or periphery of the test circle. Non-reactive: Smooth grey surface Limitations of Procedure: The results of this test should not be used as a single diagnostic tool to make a clinical diagnosis. Instead, the test results must be evaluated together with other clinical findings and observed symptoms to aid in the final diagnosis. False positive reactions sometimes occur in drug abuse and in such diseases as lupus erthymatosus, mononucleosis, leprosy, viral pneumonia, and after smallpox vaccinations. Plasma specimens over 48 hours old may give erroneous results. CONTACT US: TECO DIAGNOSTICS 1268 N. Lakeview Avenue Anaheim, CA 92807 Tel: 714-463-1111 Fax: 714-463-1169 QMM.152

 Open the catalog to page 1

All Teco Diagnostics catalogs and technical brochures

  1. C509-400

    1  Page

  2. RF‐100

    1  Page

  3. URS‐11

    2  Pages

  4. P605-510TM

    1  Page

  5. ASO-100

    1  Page

  6. B577-480

    1  Page

  7. A502-480

    1  Page

  8. URS‐1A

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.