Product Description: Electrosurgical plates are used in conjunction with active electrodes and electrosurgical units during surgeries. They provide a large contact surface with the patient, reducing current flow density and minimizing risks.
Product Characteristics: The plates are latex-free, phthalate-free, and contain no animal-derived compounds. They comply with RoHS standards and are compatible with REM monitoring electrosurgical generators. Weight limitations vary by model: Adult (>15 kg), Paediatrics (5-15 kg), Neonatal (<5 kg), and Universal (>5 kg). High energy models (up to 1100mA) include 2125, while conventional models include 2225, 2425, 2500, 2510, 2600, 2700, 2900.
Technical Specifications: The backing material is waterproof PE foam with biocompatible adhesive. The conductive area consists of an aluminium/PET film with acrylic hydrogel. Cable components include plated brass staples, copper wire, and nickel-plated brass terminals. The product is packaged in PET/aluminium/PE film pouches and service boxes.
Main Dimensional Properties: The contact area dimensions vary by model, with specific measurements for unipolar and dual plates. Hydrogel thickness is 0.69mm, and cable lengths range from 280cm to 510cm.
Electrical Properties: The plates meet ANSI/AAMI and IEC standards for temperature increase and contact impedance. The cables comply with high-frequency leakage and dielectric strength requirements.
Electromagnetic Compatibility: Classified as group 1, class A product, suitable for non-domestic environments due to potential electromagnetic disturbances.
Biocompatibility: The product is non-cytotoxic, non-sensitizing, and does not cause intracutaneous irritation, complying with ISO 10993 standards.
Sterilization and Expiry Date: The product is non-sterile with a shelf life of 3 years. It should be stored away from sunlight and moisture, within a temperature range of 5-40°C.
Packaging: Available in unitary pouches or pouches containing 5 units, packaged in service boxes of 50 or 100 units.
Instructions for Use: Open the envelope only when ready to use to prevent gel drying. Apply to a well-vascularized area, avoiding bony protrusions, metallic prostheses, tattoos, or scars. Clean and dry the application area before use.
Regulatory Information: The product complies with EU Regulation 2017/745 and ISO 13485. It is classified as a Class IIb product with GMDN code 58494 and EMDN code K020102.
Annex - Plugs: Compatibility details for various connectors, including ERBE, VALLEYLAB, and AMICA types, are provided.
See more

Catalog excerpts

Pre-gelled electrosurgical plates BLAYCO-1

TECHNICAL DATA SHEET TELIC GROUP Pre-gelled electrosurgical plates BLAYCO > Product description Electrosurgical plates are used as closing element in the circuit constituted together with the active electrode and the electrosurgical unit in electrosurgical interventions. The electrode provides a large contact surface with the patient, compared with the active electrode, that allows reducing the current flow density and minimize the risk of Product charasteristics « This product does not contain natural latex, phthalates or compounds of animal or biologic origin. « This product is in compliance with RoHS standard. « Dual plates are compatible with electrosurgical generators provided with REM monitoring. Weight limitations for the patient established according to plate model are the following: - Adult « See annex of the present specification for further details about cables and their compatibilities. Compatible models for high energies up to 1100mA: 2125 Models compatible with conventional procedure: 2225, 2425, 2500, 2510, 2600, 2700, 2900 Materials « Backing material: Waterproof flexible white PE foam, closed cell, with biocompatible acrylic adhesive. + Conductive area: Aluminium / PET film with acrylic based hydrogel, biocompatible. This document is the property of Telic, S.A.U. Transmission to third-parties or non-authorized copies are not allowed 1-5

 Open the catalog to page 1
Pre-gelled electrosurgical plates BLAYCO-2

TECHNICAL DATA SHEET « Release liner: PET. » Cable (references —C/XX y —C/XX/5): - Staples: Plated brass. - Wire: Copper (10 x 0.14mm) coated with non-toxic PVC. - Inner terminal: Nickel-plated brass. - Plug: Non-toxic PVC. - Pin (cable 4212): Polycarbonate. « Pouch: PET / aluminium / PE film. « Service Box: Carton. Main dimensional properties Contact area: Conductive surface unipolar plate (em?) Conductive surface dual plate (em?) Adult Adult oblong « Hydrogel thickness: 0,69mm gel + aluminium support « Cable length: - REF-C/XX: eo Plug: See drawing in annex. Electrical properties (ANSI/AAMIEC12)...

 Open the catalog to page 2
Pre-gelled electrosurgical plates BLAYCO-3

TECHNICAL DATA SHEET . Electrical features of the cable: - High frequency leakage current (IEC 60601-2-2, cl. 201.8.8.3.102): OK. - High frequency dielectric strength (IEC 60601-2-2, cl. 201.8.8.3.103): OK. - Mains frequency dielectric strength (IEC 60601-2-2, cl. 201.8.8.3.104): OK. - Conclusion: Requirements established by electrical safety standards EN IEC 60601-2-2:2018 and ANSI/ AAMI Electromagnetic compatibility: The product is classified as group 1, class A product according to EN 55011/CISPR 11. This means that this product does not generate and/or use intentionally radio-frequency energy,...

 Open the catalog to page 3
Pre-gelled electrosurgical plates BLAYCO-4

TECHNICAL DATA SHEET TELIC GROUP Instructions for use « Do not open the envelope until the plate is ready to be used, to avoid the gel drying out. o Select a well vascularised area near the incision. « Do not place on bony protrusions, metallic prosthesis, tattoos or scars. « Avoid if possible the areas with a lot of fat under the skin. « Shave if necessary. ¢ Clean and dry the application area. « In the case of the elderly, smooth out the skin beforehand. « Apply the adhesive face of the plate smoothing and pressing lightly. « Once the intervention is finished, remove the plate gently. Regulatory...

 Open the catalog to page 4
Pre-gelled electrosurgical plates BLAYCO-5

TECHNICAL DATA SHEET Plate with cable ERBE type connector VALLEYLAB type connector VALLEYLAB type connector AMICA type connector This document is the property of Telic, S.A.U. Transmission to third-parties or non-authorized copies are not allowed 5-5

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.