Catalog excerpts
In covered stent-graft conguration: The GAP and RETROFLEX: Current issues in covered stent-graft conguration The GAP issue The lack of graft apposition against the inner wall in tightly curved anatomies ment ION SOLUT ve proximal align ro To imp inner curve e with th The RETROFLEX issue The infolding of non-clasped stent-graft when deploying in large diameter anatomies id loyme To prov n during dep io expans
Open the catalog to page 2RELAY NBS Thoracic Stent-Graft with PLUS Delivery System: Superior technology for tight curves RELY on improved alignment and superior deployment control RELY on improved proximal alignment with revised clasping conguration (2 xation points) al Proxim g pin clas system RELY on improved alignment and precision Partial graft expansion allows: • Improved alignment of the stent-graft with the Aorta • Repositioning of stent-graft for precise placement • Precision with markers closer to the landing point RELY on stent-graft control when deploying Supporting wires* provides: • Controlled expansion...
Open the catalog to page 3RELY on easy to use 4 step deployment specifically designed for the Thoracic aorta Performance Zones Relative Radial Load + High Radial Load
Open the catalog to page 4RELY on wide treatment range for all kinds of patients and main Thoracic Aortic pathologies • Lengths from 100 to 250 mm (50mm steps) • Diameters from 22 to 46 mm ( (2mm steps) p ) • Custom-made program available ogram • Straight and tapered red congurations RELY on optimal bility delivered up e conformability delivered up to 15 mm radius of curvature!!
Open the catalog to page 5In covered stent-graft conguration: PLUS Delivery System RELY on improved navigation due to smoother transition between tip and sheath RELY on improved visualization due to enhanced radiopacity and braided outer sheath Outer sheath internal view RELY on improved pushability and alignment of the Dual Sheath System: • With longer (60 cm) braided outer sheath • With new NiTi inner catheter • With new reinforced Inner Liner
Open the catalog to page 6RELY on improved introduction and advancement due to hydrophilic coating on tip and outer sheath Transport Delivery System RELY on improved ergonomics due to shorter body and coloured grips Average Frictional Force Hydrophilic Coating
Open the catalog to page 7In covered stent-graft conguration: Case: Endovascular repair in the descending aorta Institution: Ospedale Universitario San Martino, Genova, Italy Physician: Professor Carlo Ferro 1. Advancement. Position the stent-graft’s proximal markers in the desired deployment position. 2. Positioning. Retract the inner sheath until the rst covered stent begins to expand. The D-shaped marker should not be retracted past the proximal spiral support strut marker to still allow linear re-adjustments. 3. Deployment. Completely retract the inner sheath with one continuous and controlled motion without...
Open the catalog to page 8All Terumo Aortic catalogs and technical brochures
-
Relay®Plus
8 Pages
-
Thoraflex™ Hybrid
8 Pages
-
GELWEAVE™
2 Pages
-
Gelsoft™ Plus
8 Pages
-
Deployment Poster
1 Pages
-
Treovance patient brochure
8 Pages
-
Treovance Brochure
8 Pages
-
RELAY PLUS Brochure
8 Pages
-
Treovance Reference Guide
12 Pages