RELAY PLUS Brochure
8Pages

{{requestButtons}}

Catalog excerpts

RELAY PLUS Brochure - 1

with optimized THORACIC STENT-GRAFT

Open the catalog to page 1
RELAY PLUS Brochure - 2

coating on tip and outer sheath Outer sheath internal view

Open the catalog to page 2
RELAY PLUS Brochure - 3

► RELY on improved pushability and self alignment of the Dual Sheath System: • With longer (60 cm) braided outer sheath • With new NiTi® inner catheter • With new reinforced Inner Liner smoother transition enhanced radiopacity and braided outer sheath ► RELY on improved re-sheathing upon completion of implant due to a designed 'Break-away' Capture Pod

Open the catalog to page 3
RELAY PLUS Brochure - 4

► RELY on a stent-graft specif ically designed for the THORACIC AORTA i— Relative Radial Load —i i— Performance Zones —i Low Radial Load High Radial Load 1. Alignment Zone (barestents] To provide optimal alignment with the aortic anatomy. To allow proximal capture of 2. Proximal Sealing & Fixation Two stents overlap, providing multiple fixation points for improved sealing. fixation zone from the rest of Fixation Zone Secondary sealing independent Pulse Absorption Zone Location of "Spiral Support Strut" providing column 6. Distal Sealing Zone Additional apex and stent height fot secure...

Open the catalog to page 4
RELAY PLUS Brochure - 5

THORACIC STENT-GRAFT ► RELY on Flexibility and conformability • Spacing of stent zones for 3D conformability • Unique spiral support strut for adaptability and longitudinal support ► RELY on wide treatment range for all kind of patients and main Thoracic Aortic pathologies RELAY PLUS stent-graft diameters, lengths and outer sheath French size □ RELAY™ PLUS Straight □ RELAY™ PLUS Straight & Tapered ► RELY on strong material for durability • Electropolished nitinol stents • Surgical grade woven polyester graft • Surgical attachment sutures

Open the catalog to page 5
RELAY PLUS Brochure - 6

► RELY on experience of more than 4000 patients reached with RELAY and RELAY NBS Thoracic Stent-Graft RELAY™ shows lower stroke rates compared to other series of Thoracic Aortic Endografting RELAY™ shows low average number of stent-graft per patient compared to other series of Thoracic Aortic Endografting Source: I.V. Riambau on behalf of RESTORE collaborators. European experience with Relay™: a new stent-graft and delivery system for thoracic and arch lesions. Journal of Cardiovascular Surgery. J CARDIOVASC SURG 2008; 49:407-15. 2. Greenberg et al. Endovascular repair of thoracic aortic...

Open the catalog to page 6
RELAY PLUS Brochure - 7

RELAY CASE STUDY ► Type I endoleak solved by RELAY Thoracic Stent-Graft implantation Prof. Hutll Kalman - Prof. Acsady Gydrgy. Hospital Semmelweis University, Budapest, Hungary. We report a case of a patient (male, 71ys) that already had a previous TEVAR procedure (two TAG stent-graft implanted). Due to the difficult anatomy the TAG stent-graft implantation resulted in typel Following carotid-carotid by-pass operation, a RELAY Stent-Graft was implanted proximally and the lesion Thoracic stent-grafts are a preferred option to traditional surgery for patients requiring treatment for main...

Open the catalog to page 7
RELAY PLUS Brochure - 8

THORACIC STENT-GRAFT ► RELY on improved introduction and advancement due to hydrophilic coating on tip and outer sheath ► RELY on improved ergonomics due to shorter body ► RELY on improved pushability and self alignment of the Dual Sheath System ► RELY on improved navigation due to smoother transition between tip and sheath ► RELY on improved visualization due to enhanced radiopacity and braided outer sheath When treating Aneurysms and Dissections in Thoracic Aorta

Open the catalog to page 8