video corpo

1300 Series A2

1300 Series A2
1 / 76 PagesView full catalog

1300 Series A2

Product catalog summary
Introduction
The manual is for the Thermo Scientific 1300 Series Class II, Type A2 Biological Safety Cabinet, designed to protect users, the environment, and research from harmful substances. It covers various models with different sizes and voltage specifications.
Specifications
The 1300 Series A2 features SmartFlow™ technology for automatic airflow compensation, ensuring safe working conditions. It includes HEPA filters for downflow and exhaust air purification, a plenum assembly, and optional UV lighting. The control panel displays filter life, airflow velocities, and UV disinfection time.
Safety Systems
The cabinet includes service valve access ports, a stainless steel work surface, and optional armrests. It uses a negative pressure air system with HEPA filters for personnel and product protection. Safety features include a UV light lockout when the front window is open and Digital Airflow Verification (DAVe) for monitoring airflow velocities.
Installation and Operation
Instructions cover installation, start-up, and operation, including assembling the stand, leveling the cabinet, and connecting power. Guidelines for loading the chamber and operating modes are provided. Installation requirements include a non-flammable location, proper ventilation, and ambient conditions up to 6562 ft. above sea level.
Maintenance and Cleaning
Regular maintenance includes cleaning stainless steel and coated surfaces, disinfection, and UV disinfection. Procedures for changing UV disinfection time and decontaminating microbiological spaces are outlined. Cleaning involves non-caustic cleaners and UV disinfection after cleaning.
Testing and Certification
The manual details certification testing, including HEPA filter leak tests and airflow pattern tests, ensuring compliance with NSF/ANSI 49 standards. Certification should be conducted at installation and annually.
Operating Modes
The cabinet has several operating modes: OFF, Window Open, Working, Standby, and UV Mode, each with specific functions and LED indicators.
Recommendations for Safe Operation
Recommendations include using personal protective equipment, minimizing air turbulence, and ensuring proper seating posture during extended work periods.
Unit Shut-down and Disposal
For extended periods, decontaminate the unit completely before storage or disposal. HEPA filters must be discarded according to regulations.
Certification Testing Overview
Certification testing ensures the safety of personnel, products, and the environment, following NSF/ANSI 49 standards. Tests include inflow and downflow velocity, airflow smoke patterns, and HEPA filter leak tests.
Service Level Procedures
Service level procedures involve adjusting inflow velocity and verifying airflow alarms. Certification testing includes window alarms and exhaust system performance tests.
Contact Information
For assistance, contact Thermo Fisher Scientific Inc., 401 Millcreek Road, Marietta, Ohio 45750, United States. Website: www.thermofisher.com
See more

Catalog excerpts

1300 Series A2-1

User Manual 1300 Series A2 Class II, Type A2 Biological Safety Cabinet Operating Manual 7021355 Rev. 18 Visit us online to register your warranty www.thermoscientific.com/labwarranty

 Open the catalog to page 1
1300 Series A2-2

Preface Dear User, Congratulations on your purchase of a Thermo Scientific 1300 Series Class II, Type A2 biological safety cabinet! Your 1300 Series A2 biological safety cabinet has been tested and certified in accordance to NSF/ANSI 49, and is designed to protect the user, the environment, and your research from harmful substances and cross-contamination. This user’s manual provides instructions on how to use the 1300 Series A2 most effectively and safely. A printed copy of this user’s manual is available from Technical Services, if required. Containment * Comfort * Convenience™ The 1300 Series...

 Open the catalog to page 2
1300 Series A2-3

CAUTION Contains Parts and Assemblies Susceptible to Damage by Electrostatic Discharge (ESD) Important Read this instruction manual. Failure to read, understand and follow the instructions in this manual may result in damage to the unit, injury to operating personnel, and poor equipment performance. s Caution All internal adjustments and maintenance must be performed by qualified service personnel. s Material in this manual is for information purposes only. The contents and the product it describes are subject to change without notice. Thermo Fisher Scientific makes no representations or warranties...

 Open the catalog to page 3
1300 Series A2-4

Important operating and/or maintenance instructions. Read the accompanying text carefully. Potential electrical hazards. Only qualified persons should perform procedures associated with this symbol. Equipment being maintained or serviced must be turned off and locked off to prevent possible injury. Hot surface(s) present which may cause burns to unprotected skin, or to materials which may be damaged by elevated temperatures. WEEE Compliance: Thermo Fisher Scientific has contracted with companies for recycling/disposal in each EU Member State. For further information, send an email to [email protected]....

 Open the catalog to page 4
1300 Series A2-5

Do You Need Information or Assistance on Thermo Scientific Products? If you do, please contact us 8:00 a.m. to 6:00 p.m. (Eastern Time) at: 1-740-373-4763 1-800-438-4851 1-877-213-8051 http://www.thermofisher.com [email protected] www.unitylabservices.com Direct Toll Free, U.S. and Canada FAX Internet Worldwide Web Home Page Tech Support Email Address Certified Service Web Page Our Sales Support staff can provide information on pricing and give you quotations. We can take your order and provide delivery information on major equipment items or make arrangements to have your...

 Open the catalog to page 5
1300 Series A2-6

Table of Contents Section 1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 Optional Exhaust Transition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 Exhaust System Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 Moving the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4 Service Valve Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Universal Piping Connections . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 6
1300 Series A2-7

Certification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-1 Classification of the Safety Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . .8-1 Test Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-1 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-2 Test Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-3 Testing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 7
1300 Series A2-8

Figure 1-1. Unit Components The Thermo Scientific 1300 Series A2 offers innovative SmartFlow™ technology; an automatic airflow compensation system that adjusts motor speed as filters load, without the use of a manual damper. The SmartFlow™ system ensures safe working conditions, even between annual certifications. The plenum assembly consists of a plenum for the downflow blower and a plenum for the exhaust air blower. Each blower includes a filter. The exhaust air is discharged through an opening in the top of the cabinet. Chamber lighting includes one fluorescent bulb for 4 foot models and two...

 Open the catalog to page 8
1300 Series A2-9

Three service valve access ports are located on each side panel. When installing service valves, remove the center of the port plugs at the perforations. The optional stand may be ordered in two configurations; a manually adjustable from 30” to 38” working height, and a fixed 34” working height with attached casters. A stainless steel one-piece work surface is standard. Optional armrests ensure a comfortable working position for the user and minimize blockage of airflow at the front grille. Internal outlets, provided as the power source for accessories, are provided standard in the following...

 Open the catalog to page 9
1300 Series A2-10

Safety Systems (continued) HEPA filters The downflow air within the chamber and the exhaust air are cleaned by HEPA filters. Safety lockout To protect from UV radiation, the optional UV light will not turn on if the front window is open. While the UV light is on, the front window should remain closed. The closed window blocks out the UV rays. Opening the window will cause the UV light to turn off. Digital Airflow Verification (DAVe) Independent monitoring of inflow and downflow air velocities guarantees that product and personnel protection remain uncompromised. Airflow monitoring determines...

 Open the catalog to page 10
1300 Series A2-11

HEPA Filters The filter system consists of two HEPA filters for downflow (supply) and exhaust air. Room air is drawn into the sample chamber through the work position window opening. The room air is drawn into the negative pressure drain pan air duct, then pulled into the air Ultrapure air plenum in the top portion of the cabinet. The room air is mixed Exhaust air filter with recirculating Exhaust blower HEPA filtered air from the chamber, and filtered proportionally Supply blower by the downflow and exhaust filters. The Supply filter filtered air is then Ultrapure air supplied as ultra-pure...

 Open the catalog to page 11

All Thermo Scientific catalogs and technical brochures

  1. CryoStar NX50

    2  Pages

  2. Multifuge

    58  Pages

  3. MaxQ 6000

    40  Pages

  4. LTQ XL™

    4  Pages

  5. Furnaces

    2  Pages

  6. native MS

    16  Pages

  7. RM 200 EG

    4  Pages

  8. Darwin LIMS

    2  Pages

  9. Konelab 20

    2  Pages

  10. Indiko

    6  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.