Thermo Scientific E1-ClipTip Electronic Pipette Single Channel Multichannel Adjustable Tip Spacing Equalizer User Manual Thermo Fisher Scientific Thermo Scientific E1-ClipTip User Manual 1
Open the catalog to page 1Regulatory Notices FCC Class B Digital Devices Regulatory Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation....
Open the catalog to page 2Singapore compliance label Complies with IDA Standards DA107248 根據 NCC 低功率電波輻射性電機管理辦法規定 : 第十二條 經型式認證合格之低功率射頻電機, 非經許可, 公司、 商號或使用者均不得擅自變更 頻率、 加大 功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時, ; 應立即停用, 並改善至無干擾時方得繼續使用。 前項合法通信, 指依電信法規定作業之無線電通信。 低功率射 頻電機須忍受合法通信或工業、 科學及醫療用電波輻射性電機設備之干擾。 The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Thermo Fisher Scientific is under license. Other trademarks and trade names are those of their respective owners. Der Bluetooth®-Schriftzug und die Logos sind eingetragene Markenzeichen...
Open the catalog to page 3CONTENT Regulatory Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 A. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 A.1 Thermo Scientific E1-ClipTip Pipette Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 A.1.1 Thermo Scientific E1-ClipTip Model Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 A.2 Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 4D.2.1.5.6 Air gap – a selected volume of air used to separate two liquids. . . . . . . . . . . 36 D.2.1.5.7 Auto – Repeated dispensing of the same volume on defined time intervals. . 36 D.2.1.5.8 Timer – Selected time before the next step can be performed. . . . . . . . . . . . . 37 D.2.1.5.9 Note text – a note text (e.g. a reminder) can be added . . . . . . . . . . . . . . . . . . 37 D.2.1.5.10 Tip eject – Ejection of the tips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D.2.1.5.11 Loop step – repeat selected steps for the desired amount of cycles . . . . . . 37...
Open the catalog to page 5E.4.3.2 Inaccuracy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 E.4.3.3 Imprecision. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 E.5 Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 E.5.1 Changing Default Calibration Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 E.5.2 Creating Special Adjustments . . . . . ....
Open the catalog to page 6A. INTRODUCTION Congratulations on purchasing a Thermo Scientific E1-ClipTip Electronic Pipette! The Thermo ScientificTM E1-ClipTip TM is a general purpose electronic micropipette that operates on the air-displacement principle. Its intended use is for aspirating and dispensing liquids. The E1-ClipTip operates only with Thermo ScientificTM ClipTipTM pipette tips. Notice the difference with the E1-ClipTip Electronic Pipette Ideal experience even for complex protocols When combined with the secure, interlocking ClipTip technology*, the electronic pipetting action and flexible user interface, the...
Open the catalog to page 7Using this Manual Read the User Manual before using the device (pipette and tip) for the first time. Please check the User Manual if needed. Package 1. E1-ClipTip Pipette 2. Universal charger 3. Service tool A (1062800) 4. Service tool B (1062500) *not included in multichannel pipettes 5. Tip Fitting tool C (0300070) *not included in 384 multichannel pipettes 6. Instructions for Use 7. Tip Fitting sealing-ring *not included in 384 pipettes 8. Li-ion battery 9. USB cable Remove the content from the package and check that all items listed above are included. Inspect for possible shipping damage....
Open the catalog to page 8A.1.1 Thermo Scientific E1-ClipTip Model Selection E1-ClipTip Single Channel models Cat.no. Cat.no. Volume Standard Bluetooth Channels Range (ul) model Color Code Compatible ClipTip Volume Calibration Color Compatible Range (ul) Range (ul)* Code ClipTip Cat.no. Cat.no. Tip Spacing Volume Calibration Color Compatible Standard Bluetooth Channels (mm) Range (ul) Range (ul)* Code ClipTip model 4672050 4672080 4672090 4672100 4672010 4672030 4672060 4672020 4672040 4672070 *Calibration Range according to ISO8655 standards Thermo Fisher Scientific Thermo Scientific E1-ClipTip User Manual 9
Open the catalog to page 9A.2.1 Intended Use The intended use of the device is to transfer liquids with different properties accurately and reliably. The E1-ClipTip pipette and ClipTip tips are designed to be part of an analyzing system for an end user, who is responsible for the validation of the system to enable production of reliable and safe results. The performance related cautions in Chapter: E: CALIBRATION AND ADJUSTMENT should be checked. If the pipetting performance is critical for the outcome of the specific application, the result has to be assured with an alternative test, and if this is not an option, by...
Open the catalog to page 10A.2.3 Safety Precautions The following safety precautions provide important information intended to prevent personal injury to the operator and/or others, and damage to the E1-ClipTip pipette. Warning Follow general instructions for hazard prevention and safety instructions; e.g., wear protective clothing, eye protection, and gloves. Warning Follow the ergonomic guidelines for laboratory work to minimize the risk of repetitive strain injury (RSI), e.g., the Good Laboratory Pipetting Guide available at www.thermoscientific.com/glp. Warning Follow the safety instructions and general laboratory...
Open the catalog to page 112 Pages
54 Pages
58 Pages
52 Pages
196 Pages
37 Pages
4 Pages
25 Pages
40 Pages
13 Pages
6 Pages
76 Pages
28 Pages
7 Pages
40 Pages
54 Pages
412 Pages
16 Pages
4 Pages
4 Pages
6 Pages
2 Pages
12 Pages
2 Pages
4 Pages
8 Pages
2 Pages
3 Pages
8 Pages
12 Pages
16 Pages
12 Pages
16 Pages
9 Pages
16 Pages
2 Pages
8 Pages
2 Pages
128 Pages
4 Pages
2 Pages
292 Pages
68 Pages
15 Pages
8 Pages
16 Pages
222 Pages
2 Pages
4 Pages
2 Pages
6 Pages