Regulatory Notices
This section ensures compliance with FCC and Industry Canada regulations, focusing on preventing harmful interference and adhering to radio frequency exposure limits. It advises users on interference mitigation and international standards compliance.
Introduction
The manual introduces the Thermo Scientific E1-ClipTip pipette models, detailing their features, safety guidelines, and intended use. It emphasizes model selection and safety precautions.
Getting Started
Covers initial setup, including battery installation, charging, and power supply usage. Instructions for using the charging stand and power-saving features are included.
Pipette Overview
Details the pipette components, including the keypad, operation keys, and rotating display. It explains the ClipTip interface, tip attachment, and ejection, as well as adjustable tip spacing.
Recommendations for Accurate Pipetting
Offers best practices for achieving precise and accurate pipetting results.
Programming and Operation
Describes the user interface, pipetting functions, and provides step-by-step instructions for creating and editing sequences.
Supporting Functions
Covers additional features like user profiles, Thermo Fisher Cloud integration, and settings for sounds, connections, and calibration.
Power Function and Application Examples
Explains power management features and provides practical application examples for the pipette.
Calibration and Adjustment
Includes procedures for calibrating and adjusting the pipette to maintain accuracy and performance.
Troubleshooting
Guidance for resolving common issues with the E1-ClipTip pipette.
Maintenance
Outlines regular and preventive maintenance instructions, including replacing parts, cleaning, and disposal procedures.
Technical Data
Provides technical specifications and data for the E1-ClipTip pipette models.
Warranty
The pipette comes with a two-year warranty for registered devices and a one-year warranty for non-registered ones.
Technical Service
Instructions for packing the pipette for service are provided.
Safety
Highlights safety symbols, precautions, and warnings to prevent injury and damage.
Installation and Battery Management
Details battery installation, charging, and replacement procedures.
Power Supply and Charging
Instructions for using the power supply and charging the pipette safely.
Operation and Power Saving
Describes how to operate the pipette and its power-saving features.
Keypad and Operation
Explains the keypad functions and operation keys for pipetting.
ClipTip Interface and Tip Attachment
Details the ClipTip technology for secure tip attachment and ejection.
Adjustable Tip Spacing
Explains how to adjust tip spacing for different vessel configurations.
Specifications and Procedures
Provides detailed instructions for pipetting techniques and adjustments for accuracy.
Device Compatibility and Safety
Ensures compatibility between pipette and tips and highlights safety measures.
User Interface and Programming
Describes the user-friendly interface and programming functions for pipetting sequences.
Pipetting Functions
Details various pipetting functions and customization options.
Additional Features
Includes programming via My Pipette Creator App and Thermo Fisher Cloud.
Settings
Details settings for sounds, connections, calibration, and service tracking.
Power Function
Allows manual shutdown and automatic power-off for battery saving.
Application Examples
Provides examples of pipetting applications and techniques.
Dispensing Instructions
Outlines the process for dispensing liquids and performing dilutions.
Calibration and Adjustment
Explains calibration procedures and user responsibilities for accuracy.
Specifications and Standards
References ISO 8655 specifications for pipette accuracy and precision.
User Responsibilities
Emphasizes following instructions and maintaining the device for optimal performance.
Calibration Procedure
Details the recommended calibration procedure and environmental conditions.
Adjustment Settings
Instructions for changing calibration settings and creating special adjustments.
Troubleshooting
Provides solutions for common defects and display notifications.
Maintenance
Recommends regular cleaning and preventive maintenance for reliable operation.
Specifications and Procedures
Details assembly, maintenance, and operation instructions for the pipettes.
Decontamination and Sterilization
Recommends solutions and procedures for decontamination and sterilization.
Disposal Guidelines
Outlines disposal procedures for biohazardous and electronic waste.
Technical Data
Provides technical specifications for the pipette's battery and connectivity.
Warranty and Service
Details warranty coverage and service recommendations.
Materials and Construction
Describes the materials used in the pipette's construction.
Appendices
Includes conversion tables and manufacturer specifications.
Specifications
Provides detailed specifications for different pipette models.
Calibration Specification Limits
Outlines ISO8655 calibration specification limits for accuracy and precision.
Spare Parts and Accessories
Lists spare parts and accessories with order numbers for reference.
ClipTip System Compatibility
Includes a compatibility chart for ClipTip systems and pipette models.
Ordering Information
Provides ordering details for ClipTip tips and accessories.
Key Takeaways
The E1-ClipTip pipettes are designed for precision and accuracy, with essential information for maintenance and ordering parts.
Product Specifications
Lists specifications for ClipTip filter reloads and empty racks.
Manufacturer Information
Provides contact details and website information for Thermo Fisher Scientific.
Additional Information
Includes trademark and patent information, and notes on product availability.
See more

Catalog excerpts

E1-ClipTip Electronic Pipette-1

Thermo Scientific E1-ClipTip Electronic Pipette Single Channel Multichannel Adjustable Tip Spacing Equalizer User Manual Thermo Fisher Scientific Thermo Scientific E1-ClipTip User Manual 1

 Open the catalog to page 1
E1-ClipTip Electronic Pipette-2

Regulatory Notices FCC Class B Digital Devices Regulatory Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation....

 Open the catalog to page 2
E1-ClipTip Electronic Pipette-3

Singapore compliance label Complies with IDA Standards DA107248 根據 NCC 低功率電波輻射性電機管理辦法規定 : 第十二條 經型式認證合格之低功率射頻電機, 非經許可, 公司、 商號或使用者均不得擅自變更 頻率、 加大 功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象時, ; 應立即停用, 並改善至無干擾時方得繼續使用。 前項合法通信, 指依電信法規定作業之無線電通信。 低功率射 頻電機須忍受合法通信或工業、 科學及醫療用電波輻射性電機設備之干擾。 The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Thermo Fisher Scientific is under license. Other trademarks and trade names are those of their respective owners. Der Bluetooth®-Schriftzug und die Logos sind eingetragene Markenzeichen...

 Open the catalog to page 3
E1-ClipTip Electronic Pipette-4

CONTENT Regulatory Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 A. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 A.1 Thermo Scientific E1-ClipTip Pipette Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 A.1.1 Thermo Scientific E1-ClipTip Model Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 A.2 Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 4
E1-ClipTip Electronic Pipette-5

D.2.1.5.6 Air gap – a selected volume of air used to separate two liquids. . . . . . . . . . . 36 D.2.1.5.7 Auto – Repeated dispensing of the same volume on defined time intervals. . 36 D.2.1.5.8 Timer – Selected time before the next step can be performed. . . . . . . . . . . . . 37 D.2.1.5.9 Note text – a note text (e.g. a reminder) can be added . . . . . . . . . . . . . . . . . . 37 D.2.1.5.10 Tip eject – Ejection of the tips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 D.2.1.5.11 Loop step – repeat selected steps for the desired amount of cycles . . . . . . 37...

 Open the catalog to page 5
E1-ClipTip Electronic Pipette-6

E.4.3.2 Inaccuracy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 E.4.3.3 Imprecision. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 E.5 Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 E.5.1 Changing Default Calibration Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 E.5.2 Creating Special Adjustments . . . . . ....

 Open the catalog to page 6
E1-ClipTip Electronic Pipette-7

A. INTRODUCTION Congratulations on purchasing a Thermo Scientific E1-ClipTip Electronic Pipette! The Thermo ScientificTM E1-ClipTip TM is a general purpose electronic micropipette that operates on the air-displacement principle. Its intended use is for aspirating and dispensing liquids. The E1-ClipTip operates only with Thermo ScientificTM ClipTipTM pipette tips. Notice the difference with the E1-ClipTip Electronic Pipette Ideal experience even for complex protocols When combined with the secure, interlocking ClipTip technology*, the electronic pipetting action and flexible user interface, the...

 Open the catalog to page 7
E1-ClipTip Electronic Pipette-8

Using this Manual Read the User Manual before using the device (pipette and tip) for the first time. Please check the User Manual if needed. Package 1. E1-ClipTip Pipette 2. Universal charger 3. Service tool A (1062800) 4. Service tool B (1062500) *not included in multichannel pipettes 5. Tip Fitting tool C (0300070) *not included in 384 multichannel pipettes 6. Instructions for Use 7. Tip Fitting sealing-ring *not included in 384 pipettes 8. Li-ion battery 9. USB cable Remove the content from the package and check that all items listed above are included. Inspect for possible shipping damage....

 Open the catalog to page 8
E1-ClipTip Electronic Pipette-9

A.1.1 Thermo Scientific E1-ClipTip Model Selection E1-ClipTip Single Channel models Cat.no. Cat.no. Volume Standard Bluetooth Channels Range (ul) model Color Code Compatible ClipTip Volume Calibration Color Compatible Range (ul) Range (ul)* Code ClipTip Cat.no. Cat.no. Tip Spacing Volume Calibration Color Compatible Standard Bluetooth Channels (mm) Range (ul) Range (ul)* Code ClipTip model 4672050 4672080 4672090 4672100 4672010 4672030 4672060 4672020 4672040 4672070 *Calibration Range according to ISO8655 standards Thermo Fisher Scientific Thermo Scientific E1-ClipTip User Manual 9

 Open the catalog to page 9
E1-ClipTip Electronic Pipette-10

A.2.1 Intended Use The intended use of the device is to transfer liquids with different properties accurately and reliably. The E1-ClipTip pipette and ClipTip tips are designed to be part of an analyzing system for an end user, who is responsible for the validation of the system to enable production of reliable and safe results. The performance related cautions in Chapter: E: CALIBRATION AND ADJUSTMENT should be checked. If the pipetting performance is critical for the outcome of the specific application, the result has to be assured with an alternative test, and if this is not an option, by...

 Open the catalog to page 10
E1-ClipTip Electronic Pipette-11

A.2.3 Safety Precautions The following safety precautions provide important information intended to prevent personal injury to the operator and/or others, and damage to the E1-ClipTip pipette. Warning Follow general instructions for hazard prevention and safety instructions; e.g., wear protective clothing, eye protection, and gloves. Warning Follow the ergonomic guidelines for laboratory work to minimize the risk of repetitive strain injury (RSI), e.g., the Good Laboratory Pipetting Guide available at www.thermoscientific.com/glp. Warning Follow the safety instructions and general laboratory...

 Open the catalog to page 11

All Thermo Scientific catalogs and technical brochures

  1. CryoStar NX50

    2  Pages

  2. Multifuge

    58  Pages

  3. MaxQ 6000

    40  Pages

  4. 1300 Series A2

    76  Pages

  5. LTQ XL™

    4  Pages

  6. Furnaces

    2  Pages

  7. native MS

    16  Pages

  8. RM 200 EG

    4  Pages

  9. Darwin LIMS

    2  Pages

  10. Konelab 20

    2  Pages

  11. Indiko

    6  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.