Foreword Before starting to use the centrifuge, read through this manual carefully and follow the instructions. The information contained in this instruction manual is the property of Thermo Fisher Scientific; it is forbidden to copy or pass on this information without explicit approval. Failure to follow the instructions and safety information in this instruction manual will result in the expiration of the seller’s warranty. Thermo Fisher Scientific
Open the catalog to page 7
Accident Prevention Prerequisite for the safe operation of the KR4i is a work environment in compliance with the following standards, directives and trade association safety regulations and proper instruction of the user: • EEC Directive 89/391/EEC on “Measures for Improving the Safety and Health Protection of the Worker on the Job” Accident Prevention & Insurance Association Regulation A1 – Principles of Prevention Accident Prevention & Insurance Association Regulation A3 – Electrical Systems and Equipment BGR 500 – Operation of Equipment, Chapter 2.11 “Machines of Chemical Processing...
Open the catalog to page 8
Precautions In order to ensure safe operation of the KR4i, the following general safety regulations must be followed: • The centrifuge should be operated by trained personnel only. The centrifuge is to be used for its intended purpose only. “Proper use” on page vi. Do not move the centrifuge while it is running. Do not use rotors which show any signs of corrosion and/or cracks. Do not touch the electronic components of the rotor and do not make any changes to the electronic or mechanical components. Use only with rotors which have been expertly installed. Use only with rotors which have...
Open the catalog to page 9
Rotor installation: make sure the rotor is locked properly into place before operating the centrifuge. Especially when working with corrosive samples (salt solutions, acids, bases), the accessory parts and vessel have to be cleaned carefully. Always balance the samples. Centrifuging hazardous substances: • Do not centrifuge explosive or flammable materials or substances which could react violently with one another. The centrifuge is neither inert nor protected against explosion. Never use the centrifuge in an explosion-prone environment. Do not centrifuge toxic or radioactive materials or...
Open the catalog to page 10
product Description The Jouan KR4i centrifuge is designed to separate substances of different density by centrifugal force. Different rotors can be fitted to the drive in order to match the sample containers and the required performance. The maximum speed (and, by consequence, the resultant centrifugal force) is a function of the rotor in use. A control system permits the speed, acceleration and braking rates, run time and temperature to be monitored and controlled. The refrigeration is assured by a refrigerant group charged with a CFC-free fluid. The refrigerant fluid circulates around the...
Open the catalog to page 11
Chapter 1 Presentation of product Note To calculate actual results, press the keys on a pocket calculator in the order shown. Primary calculations Key sequence (not valid for CASIO, HP) To determine actual ‘g’ achieved at a different speed: N2 2 RCF2 = RCF1 ⎛ -------⎞ ⎝ N1⎠ To determine actual speed required to achieve a different ‘g’ at the same radius: N2 = N1 To determine actual speed required to achieve the same ‘g’ at a different radius: N2 = N1 Drive System The rotor is driven by a three phase asynchronous motor. The rotor is situated in the centre of an armour plated centrifugation...
Open the catalog to page 12
Chapter 1 Presentation of product KR4i Height (lid open) Height (lid closed) Weight (uncrated) Weight (crated) Rquired surface area Electrical Specifications Average power Maximum power 4 x 1600 ml 6 x 1000 ml 8 or 12 quin. or quad. bags, with or without filter 4 x 2160 ml; 6 x 2000 ml buckets 10 rpm ± 10 rpm Thermo Fisher Scientific Range Step
Open the catalog to page 13
Chapter 1 Presentation of product Max. load on drive shaft Note The maximum rotational energy is not systematically that obtained with the maximum permissible load on the drive shaft. KR4i Range Acceleration rates Braking rates High visibility digital display, 240 x 128 pixels Memory size Program protection Individual password Winshielded rotor RP4 (Cat N° 11178250) Bucket Load density Load weight kg/bucket* Load density bucket maximum speed Winshielded rotor RP6 (Cat N° 11178252) Bucket Load weight kg/bucket* Thermo Fisher Scien
Open the catalog to page 14
Chapter 1 Presentation of product Winshielded rotor RP6 (Cat N° 11178252) N6CD Cylindrical Hard anodised N6CE Cylindrical Sealed N6B Biochemistry Rectangular open N6BMT Rect. Winshielded rotor RC6 (Cat N° 11178254) Bucket Load density Load weight kg/bucket* Load density Load weight kg/bucket* Accessories have been marked with a maximum usable lifetime, that must be respected. For commentary concerning expected lifetime of accessories, please refer to section 5.13. Only accessories specifically designed for use with the Jouan KR4i are authorized for use with this centrifuge. The accessories...
Open the catalog to page 15
Chapter 1 Presentation of product Designed for multi purpose uses: blood banking (6 quad bags), large volume processing (6 x 1000 ml), biochemistry (cylindrical plastic inserts). It can be equipped with a lid: the performance then rises from 4300 rpm to 4900 rpm (5623 x g to 7301 x g). RP6 windshielded 6 place swing-out rotor, without lid (12 quin or quad bags): Designed for multi purpose uses: blood banking (12 quin bags or quad bags), large volume processing (6 x 1000 ml), biochemistry (cylindrical or rectangular plastic inserts), and microtitre carriers. The maximum authorized speed,...
Open the catalog to page 16
Chapter 1 Presentation of product Blood Banking Blood Banking Large Volumes 11178256 with partition (2 quin or quad bags) 11178157 with partition (2 quad bags) 11178203 (1 triple or quad bags) 11178195 Set of 6 for 4 buffy coat bags Blood Banking Large Volumes 11178203 (1 triple or quad bags) Table 1-4. RHK 4 B RIA RIA bucket 11174023 Set of 2 + Trays (See detailed table) RPM Thermo Fisher Scientific
Open the catalog to page 17All Thermo Scientific catalogs and technical brochures
-
CryoStar NX50
2 Pages
-
MSC-Advantage BSC
54 Pages
-
Multifuge
58 Pages
-
Thermo Scientific Pico 17 / 21
52 Pages
-
CO2 Incubator HERAcell 150 i / 240 i
196 Pages
-
Revco® Blood Bank Refrigerators
37 Pages
-
Multidrop Combi nL
4 Pages
-
Forma Environmental Chambers
25 Pages
-
MaxQ 6000
40 Pages
-
Multi Tube Rotator
13 Pages
-
picoSpin Spectrometer
6 Pages
-
1300 Series A2
76 Pages
-
CO2 Incubator Family
28 Pages
-
CO2 incubators
7 Pages
-
MaxQ Mini 4450 Shaker
40 Pages
-
E1-ClipTip Electronic Pipette
108 Pages
-
Varioskan™ LUX
54 Pages
-
ISQ Series Mass Spectrometers
412 Pages
-
Q Exactive™ BioPharma
16 Pages
-
Q Exactive Plus
4 Pages
-
LTQ XL™
4 Pages
-
Platinum DNA polymerases
6 Pages
-
-80°C Benchtop Freezer
2 Pages
-
Nicolet iS10 FT-IR Spectrometer
12 Pages
-
Ion S5 and Ion S5 XL Systems
2 Pages
-
SureTect Range
4 Pages
-
QuantStudio™ 3
8 Pages
-
Furnaces
2 Pages
-
Nunc Serological Pipettes
3 Pages
-
Nunc Cell Factory systems
8 Pages
-
Vanquish Duo UHPLC System [ZH]
12 Pages
-
native MS
16 Pages
-
Compound Discoverer Software
12 Pages
-
Vanquish Horizon UHPLC System
16 Pages
-
Thermo Scientific TSQ Duo
9 Pages
-
Thermo Scientific TSQ 8000 Evo
16 Pages
-
Heraeus Labofuge 300
2 Pages
-
Heraeus Cryofuge 5500i
8 Pages
-
Heraeus Clinifuge Centrifuge
2 Pages
-
Vials and Closures Catalog 2014-2015
128 Pages
-
RM 200 EG
4 Pages
-
Darwin LIMS
2 Pages
-
Immunohistory Solutions
292 Pages
-
Process Water Products Catalog
68 Pages
-
Technical Training Catalog
15 Pages
-
FBS Alternatives
8 Pages
-
Pierce Magnetic Beads
16 Pages
-
interactive catalog today
222 Pages
-
HERAGUARD HPH clean benches
2 Pages
-
MBC 240 Bench Top Analyzer
4 Pages
-
Konelab 20
2 Pages
-
Indiko
6 Pages