video corpo

Multifuge

Multifuge
1 / 58 PagesView full catalog

Multifuge

Product catalog summary
Preface: The manual stresses the importance of reading instructions before using the centrifuge, noting that the information is proprietary to Thermo Fisher Scientific and that not following instructions voids the warranty.
Scope of Supply: The package includes the Multifuge X1 centrifuge, power supply cable, instruction manual, and anti-corrosion oil. Missing parts should be reported to Thermo Fisher Scientific.
Intended Use: Designed for in vitro diagnostic use, the centrifuge separates components in human samples and other materials and should be operated by trained specialists.
Accident Prevention: Safe operation requires adherence to safety standards and proper training. Key measures include maintaining a safe distance, ensuring the mains plug is accessible, and using only approved rotors and accessories.
Precautions: The centrifuge should be used only for its intended purpose, operated by trained specialists, and plugged into grounded sockets. It should not be moved while running, and only approved rotors should be used. The lid should never be opened while the rotor is in motion.
Introduction and Description: The Multifuge X1/X1R is an in-vitro diagnostics device with several rotors and a user-friendly control panel. It features a maintenance-free induction motor, safety features like a steel housing, and electronic imbalance recognition.
Technical Data: The centrifuge operates up to 2000 meters above sea level, with a maximum speed of 15200 rpm and a noise level below 63 dB(A). It has a temperature setting range from -10°C to +40°C.
Specifications: The centrifuge has a galvanized steel chassis, stainless steel chamber, induction drive, microprocessor-controlled system, and easy-to-clean keypad. It offers 9 acceleration and 10 braking curves, automatic rotor recognition, and electronic imbalance recognition.
Electrical Connection: Specific electrical connections are required depending on the model, such as 230 V ±10% at 50/60 Hz for the refrigerated model.
Rotor Selection: Various rotors are available, such as TX-400, TX-200, and BIOShieldTM 720, with technical data in their respective manuals.
Before Use: Check for shipping damage and ensure the order is complete. Set up the centrifuge indoors on a stable, well-ventilated surface with a safety zone of at least 30 cm.
Operation: Turn on the power switch, open the lid, and install the rotor using the AutoLockTM system. Enter parameters using the control panel. Features include temperature control and pretemp with cooling-equipped devices.
Control Panel: Allows user intervention for controlling the operating mode, including starting and stopping the centrifuge, opening the lid, and selecting programs and parameters.
Safety and Maintenance: Avoid direct sunlight exposure, check sealings before aerosol-tight applications, and store in a clean, dust-free location.
Continuous Operation and Run Time Modes: Continuous operation allows manual stopping, and run time mode can be set using the TOGGLE key.
Temperature Settings: Temperatures between -10°C and +40°C can be preselected for the sample or chamber, with prewarming or precooling options.
Bucket and Radius Selection: For swing-out rotors, bucket selection is based on catalog number, and radius can be specified using the numeric pad.
Program Setup and Management: Programs can be configured, stored, and protected with passcodes. Passcode-protected programs can be overwritten with the correct passcode.
Centrifugation Process: Ensure the rotor is installed, the main switch is on, and the lid is closed. The centrifuge stops manually or automatically when the preset time expires. Imbalance is indicated by a message.
System Menu and Settings: Allows configuration of settings such as end-of-run beep, keypad beep, LCD power save, and language. Passcodes can be set for the lid and programs.
Maintenance and Care: Regular cleaning and disinfection are necessary. Use neutral solvents and avoid caustic agents. Disinfection is crucial after spills of infectious material.
Corrosion Protection and Maintenance: Treat parts with corrosion protection oil and grease the swing-out rotor bolt.
Decontamination Procedures: In case of radioactive spills, decontaminate with a solution of 70% ethanol, 10% SDS, and water. Follow safety precautions to avoid infection risks.
Maintenance and Care: Regular maintenance includes autoclaving rotors and accessories at 121°C for a maximum of 20 minutes. Annual service by authorized technicians is recommended.
Troubleshooting: Common issues include overtemperature, incorrect bucket ID, unapproved rotor, and rotor ID failure. Solutions involve checking equipment setup and contacting customer service if problems persist.
Chemical Compatibility: A chemical compatibility chart indicates resistance to different chemicals, crucial for equipment longevity and safety.
See more

Catalog excerpts

Multifuge-1

Thermo Scientific Multifuge X1 Multifuge X1R Instructions for Use 50120964-g • 06 / 2020 Visit us online to register your warranty:

 Open the catalog to page 1
Multifuge-2

WEEE Conformity This product is subject to the regulations of the EU Waste Electrical & Electronic Equipment (WEEE) Directive 2012/19/EU. It is marked by the following symbol:

 Open the catalog to page 2
Multifuge-5

P Preface Before starting to use the centrifuge, read through this instruction manual carefully and follow the instructions. The information contained in this instruction manual is the property of Thermo Fisher Scientific; it is forbidden to copy or pass on this information without explicit approval. Failure to follow the instructions and safety information in this instruction manual will result in the expiration of the sellers warranty. Scope of Supply Article Number Quantity Centrifuge Multifuge X1 Power supply cable Instruction manual If any parts are missing, please contact your nearest Thermo...

 Open the catalog to page 5
Multifuge-6

Accident Prevention Prerequisite for the safe operation of the Multifuge X1 / X1R is a work environment in compliance with standards, directives and trade association safety regulations and proper instruction of the user. The safety regulations contain the following basic recommendations: • Maintain a radius of at least 30 cm around the centrifuge. • Implementation of special measures which ensure that no one can approach the centrifuge for longer than absolutely necessary while it is running. • The mains plug must be freely accessible at all times. Pull out the power supply plug or disconnect...

 Open the catalog to page 6
Multifuge-7

• The lid emergency release may be used in emergencies only to recover the samples from the centrifuge, e.g. during a power failure (see section “Mechanical Emergency Door Release” on page 7-2). • Never use the centrifuge if parts of its cover panels are damaged or missing. • Do not touch the electronic components of the centrifuge or alter any electronic or mechanical components. • Please observe the safety instructions. Please pay particular attention to the following aspects: • Location: well-ventilated environment, set-up on a level and rigid surface with adequate load-bearing capacity. •...

 Open the catalog to page 7
Multifuge-8

This symbol refers to general hazards. CAUTION means that material damage could occur. WARNING means that injuries or material damage or contamination could occur. This symbol refers to biological hazards. Observe the information contained in the instruction manual to keep yourself and your environment safe. Thermo Scientific

 Open the catalog to page 8
Multifuge-9

1 Introduction and Description Contents • “Characteristics of the Multifuge X1 / X1R” on page 1-2 • “Technical Data” on page 1-3 • “Directives, Standards and Guidelines” on page 1-4 • “Functions and Features” on page 1-5 • “Mains Supply” on page 1-5 • “Rotor Selection” on page 1-6

 Open the catalog to page 9
Multifuge-10

Introduction and Description Characteristics of the Multifuge X1 / X1R Characteristics of the Multifuge X1 / X1R The Multifuge X1 / X1R is an in-vitro diagnostics device according to the In-Vitro Diagnostics Directive 98/79/EC. Several rotors with a wide range of tubes can be used. The set speed is reached within seconds. The maintenance-free induction motor ensures quiet and low-vibration operation even at high speeds, and guarantees a very long lifetime. The user-friendly control panel makes it easy to pre-set the speed, RCF value, running time, temperature, and running profile (acceleration...

 Open the catalog to page 10
Multifuge-11

Introduction and Description Technical Data Technical Data The technical data of the Multifuge X1 / X1R is listed in the following table. Table 1-1. Technical Data Multifuge X1 / X1R Feature Environmental conditions -Use in interior spaces -Altitudes of up to 2,000 m above sea level -max. relative humidity 80 % up to 31 °C; decreasing linearly up to 50 % relative humidity at 40 °C. permissible ambient temperature Overvoltage category Pollution degree Heat dissipation running time maximum RCF value at nmax maximum kinetic energy noise level at maximum speed temperature setting range Height Height...

 Open the catalog to page 11
Multifuge-12

Introduction and Description Directives, Standards and Guidelines Directives, Standards and Guidelines Table 1-3. Directives, Standards and Guidelines Region 98/79/EC In Vitro Diagnostics 2011/65/EU RoHS Directive on the Restriction of the use of certain Hazardous Substances in electrical and electronic equipment Protective golas of: 2006/42/EC Machinery 2014/35/EU Low Voltage 2014/30/EU Electromagnetic Compatibility (EMC) Product code JQC centrifuges for clinical use Device class 1 Emitted interference FCC Part 15 CLASS A NOTE: This equipment has been tested and found to comply with the limits...

 Open the catalog to page 12
Multifuge-13

Introduction and Description Functions and Features Functions and Features The following table gives an overview of the important functional and performance characteristicsof the Multifuge X1 / X1R. Table 1-4. Functions and Features Component / Function Description / Features Structure / Housing Galvanized steel chassis with armored plating Stainless steel Induction drive without carbon brushes Easy-to-clean keypad and display surface Internal memory The most recent data is saved RCF-selection, temperature control, pretemp with cooling equipped devices Acceleration / braking profiles 9 acceleration...

 Open the catalog to page 13
Multifuge-14

Introduction and Description Rotor Selection Rotor Selection The Multifuge X1 / X1R is supplied without a rotor. Various rotors are available to choose from. TX-400 75003629 with round buckets TX-200 with round buckets BIOShield The technical data of the rotors and the corresponding adapters and reduction sleeves for various commercially available containers can be found in the corresponding rotor operating manuals. For more information visit our website at: http://www.thermofisher.com Thermo Scientific

 Open the catalog to page 14
Multifuge-15

• “Before Setting up” on page 2-2 • “Transporting the Centrifuge” on page 2-2 • “Location” on page 2-2 • “Aligning the Centrifuge” on page 2-3 • “Mains Connection” on page 2-3 • “Storage” on page 2-4

 Open the catalog to page 15

All Thermo Scientific catalogs and technical brochures

  1. CryoStar NX50

    2  Pages

  2. MaxQ 6000

    40  Pages

  3. 1300 Series A2

    76  Pages

  4. LTQ XL™

    4  Pages

  5. Furnaces

    2  Pages

  6. native MS

    16  Pages

  7. RM 200 EG

    4  Pages

  8. Darwin LIMS

    2  Pages

  9. Konelab 20

    2  Pages

  10. Indiko

    6  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.