Catalog excerpts

Thermo Scientific Sorvall ST 16 / 16R Centrifuge Instruction Manual 50120982-g • 03 / 2020 Visit us online to register your warranty:
Open the catalog to page 1
WEEE Conformity This product is subject to the regulations of the EU Waste Electrical & Electronic Equipment (WEEE) Directive 2012/19/EU. It is marked by the following symbol:
Open the catalog to page 2
Thermo Scientific
Open the catalog to page 3
Thermo Scientific
Open the catalog to page 4
Preface Before starting to use the centrifuge, read through this instruction manual carefully and follow the instructions. The information contained in this instruction manual is the property of Thermo Fisher Scientific; it is forbidden to copy or pass on this information without explicit approval. Failure to follow the instructions and safety information in this instruction manual will result in the expiration of the sellers warranty. Scope of Supply Article Number Quantity Zentrifuge Sorvall ST 16/16R Power supply cable Instruction manual If any parts are missing, please contact your...
Open the catalog to page 5
Accident Prevention Prerequisite for the safe operation of the Sorvall ST 16/16R is a work environment in compliance with standards, directives and trade association safety regulations and proper instruction of the user. The safety regulations contain the following basic recommendations: • Maintain a radius of at least 30 cm around the centrifuge. • Implementation of special measures which ensure that no one can approach the centrifuge for longer than absolutely necessary while it is running. • The mains plug must be freely accessible at all times. Pull out the power supply plug or...
Open the catalog to page 6
• Never open the lid until the rotor has come to a complete stop and this has been confirmed in the display. • The lid emergency release may be used in emergencies only to recover the samples from the centrifuge, e.g. during a power failure (see section “Mechanical Emergency Door Release” on page 7-2). • Never use the centrifuge if parts of its cover panels are damaged or missing. • Do not touch the electronic components of the centrifuge or alter any electronic or mechanical components. • Please observe the safety instructions. Please pay particular attention to the following aspects: •...
Open the catalog to page 7
g Maximum sample density at maximum speed: 1,2 -----ml This symbol refers to general hazards. CAUTION means that material damage could occur. WARNING means that injuries or material damage or contamination could occur. This symbol refers to biological hazards. Observe the information contained in the instruction manual to keep yourself and your environment safe. Thermo Scientific
Open the catalog to page 8
Introduction and Description Contents • “Characteristics” on page 1-2 • “Technical Data” on page 1-3 • “Directives, Standards and Guidelines” on page 1-4 • “Functions and Features” on page 1-5 • “Mains Supply” on page 1-5 • “Rotor Selection” on page 1-6
Open the catalog to page 9
Introduction and Description Characteristics Characteristics The Sorvall ST 16/16R is an in-vitro diagnostics device according to the In-Vitro Diagnostics Directive 98/79/EC. Several rotors with a wide range of tubes can be used. The set speed is reached within seconds. The maintenance-free induction motor ensures quiet and low-vibration operation even at high speeds, and guarantees a very long lifetime. The user-friendly control panel makes it easy to pre-set the speed, RCF value, running time, temperature, and running profile (acceleration and braking curves). You can choose between the...
Open the catalog to page 10
Introduction and Description Technical Data Technical Data The technical data of the Sorvall ST 16/16R is listed in the following table. Table 1-1. Technical Data Sorvall ST 16/16R Feature Environmental conditions -Use in interior spaces -Altitudes of up to 2,000 m above sea level -max. relative humidity 80 % up to 31 °C; decreasing linearly up to 50 % relative humidity at 40 °C. permissible ambient temperature Overvoltage category Pollution degree Heat dissipation running time maximum RCF value at nmax maximum kinetic energy noise level at maximum speed temperature setting range Height...
Open the catalog to page 11
Introduction and Description Directives, Standards and Guidelines Directives, Standards and Guidelines Table 1-2. Directives, Standards and Guidelines Tension / Frequency Produced and inspected according to the following standards and guidelines 2006/95/EC Low Voltage Directive: IEC 61010-2-20, 2nd Edition (Pollution degree 2, Overvoltage category II) ICE 61010-2-101 Emitted interference FCC Part 15 CLASS A NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide...
Open the catalog to page 12
Introduction and Description Functions and Features Functions and Features The following table gives an overview of the important functional and performance characteristics of the Sorvall ST 16/16R. Table 1-3. Functions and Features Component / Function Description / Features Structure / Housing Galvanized steel chassis with armoured plating Stainless steel Induction drive without carbon brushes Easy-to-clean keypad and display surface Internal memory The most recent data is saved RCF-selection, temperature control, pretemp with cooling equipped devices Acceleration / braking profiles 9...
Open the catalog to page 13
Introduction and Description Rotor Selection Rotor Selection The Sorvall ST 16/16R is supplied without a rotor. Various rotors are available to choose from. 7500 3629 with round buckets with round buckets BIOShield The technical data of the rotors and the corresponding adapters and reduction sleeves for various commercially available containers can be found in the corresponding rotor operating manuals. For more information visit our website at: http://www.thermofisher.com Thermo Scientific
Open the catalog to page 14
• “Before Setting up” on page 2-2 • “Transporting the Centrifuge” on page 2-2 • “Location” on page 2-2 • “Aligning the Centrifuge” on page 2-3 • “Mains Connection” on page 2-3 • “Storage” on page 2-4
Open the catalog to page 15All Thermo Scientific catalogs and technical brochures
-
CryoStar NX50
2 Pages
-
MSC-Advantage BSC
54 Pages
-
Multifuge
58 Pages
-
Thermo Scientific Pico 17 / 21
52 Pages
-
CO2 Incubator HERAcell 150 i / 240 i
196 Pages
-
Revco® Blood Bank Refrigerators
37 Pages
-
Multidrop Combi nL
4 Pages
-
Forma Environmental Chambers
25 Pages
-
MaxQ 6000
40 Pages
-
Multi Tube Rotator
13 Pages
-
picoSpin Spectrometer
6 Pages
-
1300 Series A2
76 Pages
-
CO2 Incubator Family
28 Pages
-
CO2 incubators
7 Pages
-
MaxQ Mini 4450 Shaker
40 Pages
-
E1-ClipTip Electronic Pipette
108 Pages
-
Varioskan™ LUX
54 Pages
-
ISQ Series Mass Spectrometers
412 Pages
-
Q Exactive™ BioPharma
16 Pages
-
Q Exactive Plus
4 Pages
-
LTQ XL™
4 Pages
-
Platinum DNA polymerases
6 Pages
-
-80°C Benchtop Freezer
2 Pages
-
Nicolet iS10 FT-IR Spectrometer
12 Pages
-
Ion S5 and Ion S5 XL Systems
2 Pages
-
SureTect Range
4 Pages
-
QuantStudio™ 3
8 Pages
-
Furnaces
2 Pages
-
Nunc Serological Pipettes
3 Pages
-
Nunc Cell Factory systems
8 Pages
-
Vanquish Duo UHPLC System [ZH]
12 Pages
-
native MS
16 Pages
-
Compound Discoverer Software
12 Pages
-
Vanquish Horizon UHPLC System
16 Pages
-
Thermo Scientific TSQ Duo
9 Pages
-
Thermo Scientific TSQ 8000 Evo
16 Pages
-
Heraeus Labofuge 300
2 Pages
-
Heraeus Cryofuge 5500i
8 Pages
-
Heraeus Clinifuge Centrifuge
2 Pages
-
Vials and Closures Catalog 2014-2015
128 Pages
-
RM 200 EG
4 Pages
-
Darwin LIMS
2 Pages
-
Immunohistory Solutions
292 Pages
-
Process Water Products Catalog
68 Pages
-
Technical Training Catalog
15 Pages
-
FBS Alternatives
8 Pages
-
Pierce Magnetic Beads
16 Pages
-
interactive catalog today
222 Pages
-
HERAGUARD HPH clean benches
2 Pages
-
MBC 240 Bench Top Analyzer
4 Pages
-
Konelab 20
2 Pages
-
Indiko
6 Pages