Thermo Scientific Orbitrap Fusion Tribrid Mass Spectrometer Unmatched analytical performance
Open the catalog to page 1
Transforming biological research In the world of systems and structural biology, research objectives continue to become more challenging: digging deeper into the proteome, identifying lower abundance analytes in more-complex samples, making quantitative comparisons over more experimental conditions, elucidating structures faster. Meeting such challenges is the goal of the Thermo Scientific™ Orbitrap Fusion™ mass spectrometer. Its revolutionary Thermo Scientific™ Tribrid™ architecture combines the best of quadrupole, Orbitrap, and linear ion trap mass analyzers in a new class of instrument....
Open the catalog to page 2
Identify more analytes more quickly Increased sensitivity, scan rate, and mass resolution enhance the ability to positively identify more low-abundance proteins, such as transcription factors, in less time. Productivity is enhanced through the massive parallelization enabled by Tribrid architecture and Dynamic Scan Management. Quantify more accurately Synchronous Precursor Selection combined with MS3 significantly improves quantitative accuracy when using isobaric mass tags for relative quantitation of proteins. Elucidate structures more thoroughly The ability to use any fragmentation mode,...
Open the catalog to page 3
Revolutionary Tribrid architecture Tribrid architecture, with an independent ion-routing multipole controlled by Dynamic Scan Management, enables massive parallelization, significantly increases scan rates, and maximizes versatility. Any of three dissociation techniques—CID, HCD, and ETD—can be performed at any fragmentation stage, followed by analysis in either the linear ion trap or Orbitrap mass analyzer. Excellent sensitivity and selectivity Precursor selection using a quadrupole mass filter allows the ion trap and Orbitrap mass analyzers to operate in parallel. Wide mass range...
Open the catalog to page 4
Unsurpassed resolution and increased scan rate Ultra-high-field Orbitrap mass analyzer offers resolution in excess of 500,000 for unsurpassed separation of isobaric interferences. This novel Orbitrap design also allows for MS/MS scan rates up to 20 Hz, with unmatched spectral quality. Longer detector life Large-surface-area detector has two dynodes to capture the complete ion flux from the ion trap. The single multiplier features a very large surface area for extended lifetime. Multistage precursor ion activation (MS n) and sensitive mass analysis Dual-pressure configuration of the linear...
Open the catalog to page 5
The Universal Method eliminates method optimization for data-dependent analysis In order to maximize the number of unique peptides identified, injection times is one parameter to optimize with low and high peptide loads. The Universal Method, with no optimization, is shown here to perform equally as well as manual optimization without the added time and sample. The Universal Method: A Single Method Optimal for Multiple Sample Types 6000 Therapeutic proteins and monoclonal antibodies have transformed biotechnology and the pharmaceutical industry. Essential to the development of new...
Open the catalog to page 6
More accurate protein quantification Multiplexed analysis using isobaric mass tags such as TMT™ reagents or iTRAQ® reagents is a powerful tool, enabling quantitative comparison of protein abundances across time, conditions, tissues, subcellular locations, or other experimental variables. In conventional mass tagging experiments, reporter ions are generated at the MS2 stage. However, in complex samples, co-isolation of isobaric background peptides distorts reporter ion ratios, yielding inaccurate quantitation and masking subtle but biologically significant changes in abundance. • Goal: •...
Open the catalog to page 7
Simple, reliable ETD enhances characterization of complex PTMs Electron-transfer dissociation (ETD) is a powerful complement to CID and HCD for the analysis of proteins. It cleaves primarily along the peptide backbone, generating c and z ions, often with increased fragment coverage compared to b and y ions that dominate CID spectra. ETD leaves side chains and modifications largely intact, making it particularly useful when analyzing post-translationally modified proteins. The optional Thermo Scientific™ EASY-ETD™ ion source, designed specifically for the Orbitrap Fusion MS, is robust, easy...
Open the catalog to page 8
Multiple fragmentation types provide exceptional sequence coverage for top-down analyses The Orbitrap Fusion MS has the high resolution and accurate mass necessary to fully resolve monoclonal antibody heavy and light chains, as well as to accurately assign the complex fragmentation spectra generated from top-down experiments on large species. To maximize fragmentation for sequence characterization, proteins can be analyzed using a combination of fragmentation types including CID, HCD, ETD, and EThcD which provide complementary information. More complex experiments such as MSn analyses using...
Open the catalog to page 9
Determine structures more quickly and accurately Resolution of isobaric interferences Relative Abundance With mass resolution in excess of 500,000, the Orbitrap Fusion mass spectrometer can easily separate and identify isobaric compounds indistinguishable by other MS technologies. Structural characterization on a UHPLC timescale Relative Abundance The Tribrid architecture and Dynamic Scan Management of the Orbitrap Fusion MS deliver exceptional scan rates for applications where high throughput and fast chromatography demand the most MSn data from a single run. The quadrupole mass filter,...
Open the catalog to page 10
Maximum performance with less effort The Orbitrap Fusion Tribrid mass spectrometer delivers more, higher-quality information from more types of samples faster than any mass spectrometer available today. But more is only part of the story; the other part is less - less effort. The intelligence built into the Orbitrap Fusion instrument and software makes it possible to achieve exemplary results with far less effort than required by previous generations of mass spectrometers. This built-in intelligence helps researchers focus on their science instead of method development and instrument...
Open the catalog to page 11All Thermo Scientific catalogs and technical brochures
-
CryoStar NX50
2 Pages
-
MSC-Advantage BSC
54 Pages
-
Multifuge
58 Pages
-
Thermo Scientific Pico 17 / 21
52 Pages
-
CO2 Incubator HERAcell 150 i / 240 i
196 Pages
-
Revco® Blood Bank Refrigerators
37 Pages
-
Multidrop Combi nL
4 Pages
-
Forma Environmental Chambers
25 Pages
-
MaxQ 6000
40 Pages
-
Multi Tube Rotator
13 Pages
-
picoSpin Spectrometer
6 Pages
-
1300 Series A2
76 Pages
-
CO2 Incubator Family
28 Pages
-
CO2 incubators
7 Pages
-
MaxQ Mini 4450 Shaker
40 Pages
-
E1-ClipTip Electronic Pipette
108 Pages
-
Varioskan™ LUX
54 Pages
-
ISQ Series Mass Spectrometers
412 Pages
-
Q Exactive™ BioPharma
16 Pages
-
Q Exactive Plus
4 Pages
-
LTQ XL™
4 Pages
-
Platinum DNA polymerases
6 Pages
-
-80°C Benchtop Freezer
2 Pages
-
Nicolet iS10 FT-IR Spectrometer
12 Pages
-
Ion S5 and Ion S5 XL Systems
2 Pages
-
SureTect Range
4 Pages
-
QuantStudio™ 3
8 Pages
-
Furnaces
2 Pages
-
Nunc Serological Pipettes
3 Pages
-
Nunc Cell Factory systems
8 Pages
-
Vanquish Duo UHPLC System [ZH]
12 Pages
-
native MS
16 Pages
-
Compound Discoverer Software
12 Pages
-
Vanquish Horizon UHPLC System
16 Pages
-
Thermo Scientific TSQ Duo
9 Pages
-
Thermo Scientific TSQ 8000 Evo
16 Pages
-
Heraeus Labofuge 300
2 Pages
-
Heraeus Cryofuge 5500i
8 Pages
-
Heraeus Clinifuge Centrifuge
2 Pages
-
Vials and Closures Catalog 2014-2015
128 Pages
-
RM 200 EG
4 Pages
-
Darwin LIMS
2 Pages
-
Immunohistory Solutions
292 Pages
-
Process Water Products Catalog
68 Pages
-
Technical Training Catalog
15 Pages
-
FBS Alternatives
8 Pages
-
Pierce Magnetic Beads
16 Pages
-
interactive catalog today
222 Pages
-
HERAGUARD HPH clean benches
2 Pages
-
MBC 240 Bench Top Analyzer
4 Pages
-
Konelab 20
2 Pages
-
Indiko
6 Pages