Preface
Users must thoroughly read the instruction manual before using the Thermo Scientific Pico 17/21 centrifuge. Unauthorized copying or distribution of the manual is prohibited, and non-compliance may void the warranty.
Scope of Supply
The package includes the centrifuge, power supply cable, rotor, square box wrench, and a CD with the manual. Report missing parts to Thermo Fisher Scientific.
Intended Use
The centrifuge is designed for laboratory use to separate components by centrifugal force, suitable for human samples, chemicals, and environmental samples. It can also be used as an in-vitro diagnostics device with a specific rotor.
Accident Prevention
Ensure the centrifuge is plugged into grounded sockets and maintain a safe environment. In emergencies, such as rotor failure, evacuate the area and contact customer service.
Precautions
Only trained specialists should operate the centrifuge. It should not be moved while running, and only approved rotors and accessories should be used. Safety measures must be observed, especially when handling hazardous substances.
Introduction and Description
The Pico 17/21 features a maintenance-free induction motor, user-friendly control panel, and various safety features. It is constructed with impact-resistant plastic and armor steel.
Technical Data
The centrifuge operates at a maximum speed of 13,300 rpm and a maximum RCF of 17,000 x g. It is designed for use in interior spaces with specific environmental conditions.
Maintenance and Care
Regular cleaning, disinfection, and decontamination are necessary. Autoclaving and service by Thermo Fisher Scientific are recommended.
Troubleshooting
Basic troubleshooting can be performed by users, but complex issues should be referred to a service technician. A chemical compatibility chart is provided for reference.
Technical Specifications
  • Environmental Conditions: Suitable for indoor use at altitudes up to 2,000 m, with specific humidity and temperature ranges.
  • Electrical Specifications: Overvoltage Category II, Pollution Degree 2, with specific heat dissipation values.
  • Performance: Unlimited run time, maximum speed of 14,800 rpm, and maximum RCF value of 21,100 x g.
  • Noise Level: Less than 56 dB(A) at maximum speed.
  • Dimensions and Weight: Height 230 mm, Width 240 mm, Depth 350 mm, Weight 10.5 kg.
Directives, Standards, and Guidelines
The centrifuge complies with various international directives and standards, including those for In Vitro Diagnostics and RoHS.
Functions and Features
The centrifuge is made of sheet metal with plastic housing and steel chamber, featuring an induction drive system and various rotor options.
Setup and Operation
Includes guidelines for checking shipping damage, location requirements, mains connection, and control panel operation.
Specifications and Limitations
Highlights the operation and maintenance of the centrifuge, noting limitations such as the lifetime of plastic rotor tubes and autoclaving conditions.
Operation Procedures
Details starting and stopping procedures, short-term centrifugation, and rotor removal instructions.
Maintenance and Care
Includes cleaning, disinfection, autoclaving, and service recommendations to ensure equipment longevity.
Troubleshooting
Provides solutions for common issues and advises contacting a service technician for unresolved problems.
Chemical Compatibility Chart Overview
Offers a detailed chart categorizing material resistance to various chemicals, suggesting testing for unknown performance.
Main Sections
  • Specifications: Outlines the centrifuge's features, functions, and technical data.
  • Procedures: Provides detailed operation, maintenance, and troubleshooting procedures.
  • Standards and Recommendations: Emphasizes safety standards and provides recommendations for accident prevention and chemical handling.
  • Chemical Resistance Data: Guides product use by indicating material compatibility with specific chemicals.
Key Information
  • Safety Precautions: Includes accident prevention and precautions for safe operation.
  • Maintenance and Care: Provides cleaning, decontamination, and maintenance instructions.
  • Contact Information: Includes contact details for customer support and service inquiries.
Conclusion
The document serves as a comprehensive guide for users, providing essential information on chemical compatibility, operational procedures, and safety standards to ensure effective and safe use of the equipment.
See more

Catalog excerpts

Thermo Scientific Pico 17 / 21-1

Thermo Scientific Pico 17 / 21 Instructions for Use 50133388-e • 06 / 2020 Visit us online to register your warranty:

 Open the catalog to page 1
Thermo Scientific Pico 17 / 21-2

WEEE Conformity This product is subject to the regulations of the EU Waste Electrical & Electronic Equipment (WEEE) Directive 2012/19/EU. It is marked by the following symbol:

 Open the catalog to page 2
Thermo Scientific Pico 17 / 21-5

Preface Before starting to use the centrifuge, read through this instruction manual carefully and follow the instructions. The information contained in this instruction manual is the property of Thermo Fisher Scientific; it is forbidden to copy or pass on this information without explicit approval. Failure to follow the instructions and safety information in this instruction manual will result in the expiration of the sellers warranty. Scope of Supply Article Number Quantity Centrifuge Pico 17 / 21 Power supply cable If any parts are missing, please contact your nearest Thermo Fisher Scientific...

 Open the catalog to page 5
Thermo Scientific Pico 17 / 21-6

Intended Use • This centrifuge is a laboratory product designed to separate components by generation of a relative centrifugal force. It separates human samples (e.g. blood, urine and other body fluids) collected in appropriate containers, either alone or after addition of reagents or other additives. • As general-purpose centrifuge, it is designed to also run other containers filled with chemicals, environmental samples and other non-human body samples. • Together with the hematocrit rotor 75003473 the centrifuge can be used as an in-vitro diagnostics device to define the hematocrit value by...

 Open the catalog to page 6
Thermo Scientific Pico 17 / 21-7

Precautions In order to ensure safe operation of the Pico 17 / 21, the following general safety regulations must be followed: • The centrifuge should be operated by trained specialists only. • The centrifuge is to be used for its intended use only. • While handling centrifuge, rotor, and samples you must wear laboratory clothing (e.g. gloves). • Do not move the centrifuge while it is running. • Do not lean on the centrifuge. • Use only rotors and accessories for this centrifuge which have been approved by Thermo Fisher Scientific. Exceptions to this rule are commercially available glass or plastic...

 Open the catalog to page 7
Thermo Scientific Pico 17 / 21-8

Please pay particular attention to the following aspects: • Location: well-ventilated environment, set-up on a level and rigid surface with adequate load-bearing capacity. • Rotor installation: make sure the rotor is locked properly into place before operating the centrifuge. • Especially when working with corrosive samples (salt solutions, acids, bases), the accessory parts and vessel have to be cleaned carefully. • Always balance the samples. Centrifuging hazardous substances: • Do not centrifuge explosive or flammable materials or substances which could react violently with one another. •...

 Open the catalog to page 8
Thermo Scientific Pico 17 / 21-9

Introduction and Description Contents • “Characteristics of the Pico 17 / 21” on page 1-2 • “Technical Data” on page 1-2 • “Directives, Standards and Guidelines” on page 1-4 • “Functions and Features” on page 1-4 • “Mains Supply” on page 1-5 • “Rotor Selection” on page 1-5

 Open the catalog to page 9
Thermo Scientific Pico 17 / 21-10

Introduction and Description Characteristics of the Pico 17 / 21 Characteristics of the Pico 17 / 21 Several rotors with a wide range of tubes can be used. The set speed is reached within seconds. The maintenance-free induction motor ensures quiet and low-vibration operation even at high speeds, and guarantees a very long lifetime. The user-friendly control panel makes it easy to pre-set the speed, RCF value, run time, and temperature. You can choose between the display of speed and RCF or the entry mode. These settings can be changed even while the centrifuge is running. With the help of the...

 Open the catalog to page 10
Thermo Scientific Pico 17 / 21-11

Introduction and Description Technical Data Table 1-1. Technical data Pico 17 Feature Maximum RCF-Value at nmax Maximum Kinetic Energy Noise Level at maximum Speed Dimensions Height Width Depth Weight with emptyRotor Table 1-2. Technical data Pico 21 Feature Environmental Conditions -Use in interior Spaces -Altitudes of up to 2,000 m above Sea Level -max. relative humidity 80 % up to 31 °C; decreasing linearly up to 50 % relative humidity at 40 °C. Permissible Ambient Temperature during Operation Permissible Ambient Temperature during Storage and Transport Overvoltage Category Pollution Degree...

 Open the catalog to page 11
Thermo Scientific Pico 17 / 21-12

Introduction and Description Directives, Standards and Guidelines Table 1-2. Technical data Pico 21 Feature Height Width Depth Weight with empty Rotor Directives, Standards and Guidelines Table 1-3. Directives, Standards and Guidelines Region 2011/65/EU RoHS Directive on the Restriction of the use of certain Hazardous Substances in electrical and electronic equipment Protective goals of: 2006/42/EC Machinery 2014/35/EU Low Voltage 2014/30/EU Electromagnetic Compatibility (EMC) FDA listed Product code JQC centrifuges for clinical use Device class 1 CFDA listed Thermo Scientific

 Open the catalog to page 12
Thermo Scientific Pico 17 / 21-13

Introduction and Description Functions and Features Functions and Features The following table gives an overview of the important functional and performance characteristics of the Pico 17 / 21. Table 1-4. Functions and Features Component / Function Description / Features Structure / Housing Sheet Metal with attached Plastic Housing and Steel Chamber Rotor Chamber Plastic Up to 48 ml of spilled Liquid is retained in the Chamber and cannot enter the Instrument. Induction Drive without Carbon Brushes Easy-to-clean Keypad and Display Surface Internal Memory The most recent Data is saved RCF, Temperature,...

 Open the catalog to page 13
Thermo Scientific Pico 17 / 21-14

Introduction and Description Rotor Selection Rotor Selection The Pico 17 / 21 is supplied with a rotor. Various rotors are available to choose from. Microliter 24 x 2 Hematocrit Rotor The technical data of the rotors and the corresponding adapters and reduction sleeves for various commercially available containers can be found in the corresponding rotor operating manuals. For more information visit our website at: http://www.thermofisher.com Thermo Scientific

 Open the catalog to page 14

All Thermo Scientific catalogs and technical brochures

  1. CryoStar NX50

    2  Pages

  2. Multifuge

    58  Pages

  3. MaxQ 6000

    40  Pages

  4. 1300 Series A2

    76  Pages

  5. LTQ XL™

    4  Pages

  6. Furnaces

    2  Pages

  7. native MS

    16  Pages

  8. RM 200 EG

    4  Pages

  9. Darwin LIMS

    2  Pages

  10. Konelab 20

    2  Pages

  11. Indiko

    6  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.