video corpo

Thermo Scientific Sorvall LYNX 4000 / 6000
73Pages

{{requestButtons}}

Catalog excerpts

Thermo Scientific Sorvall LYNX 4000 / 6000 - 1

Thermo Scientific Sorvall LYNX 4000 / 6000 Superspeed Centrifuge Visit us online to register your warranty:

Open the catalog to page 1
Thermo Scientific Sorvall LYNX 4000 / 6000 - 3

WEEE Conformity This product is subject to the regulations of the EU Waste Electrical & Electronic Equipment (WEEE) Directive 2012/19/EU. It is marked by the following symbol:

Open the catalog to page 3
Thermo Scientific Sorvall LYNX 4000 / 6000 - 4

T Table of Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Scope of Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Intended Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv Symbols used in this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv Symbols used on the Centrifuge . . . . . . . . . . . . . . . . . ....

Open the catalog to page 4
Thermo Scientific Sorvall LYNX 4000 / 6000 - 5

Maintenance and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Cleaning Intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Cleaning the Touchscreen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Cleaning the Condenser Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Open the catalog to page 5
Thermo Scientific Sorvall LYNX 4000 / 6000 - 6

Preface Before starting to use the centrifuge, read through this instruction manual carefully and follow the instructions. The information contained in this instruction manual is the property of Thermo Fisher Scientific; it is forbidden to copy or pass on this information without explicit approval. Failure to follow the instructions and safety information in this instruction manual will result in the expiration of the sellers warranty. Scope of Supply Article Number Description Centrifuge Power Supply Cable Bubble Level If any parts are missing, please contact your nearest Thermo Fisher...

Open the catalog to page 6
Thermo Scientific Sorvall LYNX 4000 / 6000 - 7

Preface Intended Purpose Intended Purpose • This centrifuge is a laboratory product designed to separate components by generation of a relative centrifugal force. It separates human samples (e.g. blood, urine and other body fluids) collected in appropriate containers, either alone or after addition of reagents or other additives. • As research laboratory or bioprocessing laboratory centrifuge, it is designed to also run other containers filled with chemicals, environmental samples and other non-human body samples. g • Maximum sample density at maximum speed: 1.2 ---------3 cm • This...

Open the catalog to page 7
Thermo Scientific Sorvall LYNX 4000 / 6000 - 8

Precautions A trained specialist can be a laboratory assistant or medical technologist. WARNING • Plug the centrifuge only into sockets which have been properly grounded. • If a hazardous situation occurs, turn off the power supply to the centrifuge and leave the area immediately. Note In order to ensure safe operation of the Sorvall LYNX 4000 / 6000 centrifuge, general safety regulations must be followed: Mind the accident prevention regulations in your country. The work environment should guarantee the following: WARNING • Maintain a radius of at least 30 cm around the centrifuge. The...

Open the catalog to page 8
Thermo Scientific Sorvall LYNX 4000 / 6000 - 9

Preface Precautions WARNING In order to ensure safe operation of the Sorvall LYNX 4000 / 6000 centrifuge , the following general safety regulations must be followed: • The centrifuge should be operated by trained specialists only. • The centrifuge is to be used for its intended use only. • Do not move the centrifuge while it is running. • Do not lean on the centrifuge. • Do not place anything on top of the centrifuge during a run. This applies also for the rotor landing pad. • Use only rotors and accessories for this centrifuge which have been approved by Thermo Fisher Scientific....

Open the catalog to page 9
Thermo Scientific Sorvall LYNX 4000 / 6000 - 10

WARNING Please pay particular attention to the following aspects: • Location: well-ventilated environment, set-up on a level and rigid surface with adequate load-bearing capacity. • Rotor installation: make sure the rotor is locked properly into place before operating the centrifuge. • Especially when working with corrosive samples (salt solutions, acids, bases), the accessory parts and vessel have to be cleaned carefully. • Always balance the samples. Centrifuging hazardous substances: • Do not centrifuge explosive or flammable materials or substances which could react violently with one...

Open the catalog to page 10
Thermo Scientific Sorvall LYNX 4000 / 6000 - 11

Preface Precautions Thermo Scientific

Open the catalog to page 11
Thermo Scientific Sorvall LYNX 4000 / 6000 - 12

Introduction and Description Contents • “Characteristics of the Sorvall LYNX 4000 / 6000 Centrifuge” on page 2 • “Technical Data” on page 3 • “Directives, Standards and Guidelines” on page 4 • “Functions and Features” on page 5 • “Mains Supply” on page 6 • “Rotor Selection” on page 7 Thermo Scient

Open the catalog to page 12
Thermo Scientific Sorvall LYNX 4000 / 6000 - 13

Introduction and Description Characteristics of the Sorvall LYNX 4000 / 6000 Centrifuge Characteristics of the Sorvall LYNX 4000 / 6000 Centrifuge Several rotors with a wide range of tubes can be used. The set speed is reached within seconds. The maintenance-free induction motor ensures quiet and low-vibration operation even at high speeds, and guarantees a very long lifetime. The user-friendly control panel makes it easy to preset the speed, RCF value, run time, temperature, and run profile (acceleration and deceleration curves). You can choose between the display of speed and RCF in the...

Open the catalog to page 13
Thermo Scientific Sorvall LYNX 4000 / 6000 - 14

Introduction and Description Technical Data Technical Data The technical data of the Sorvall LYNX 4000 / 6000 centrifuge is listed in the following table. Table 1. Technical Data Feature Environmental Conditions -Use in interior Spaces -Altitudes of up to 2,000 m above Sea Level -Max. relative humidity 85% up to 30 °C Environmental Conditions during Storage and Shipping Permissible Ambient Temperature Overvoltage Category Pollution Degree IP (statement of the degree of protection according to IEC 60529) Maximum Speed nmax Minimum Speed nmin Maximum RCF-Value at nmax Maximum kinetic Energy...

Open the catalog to page 14

All Thermo Scientific catalogs and technical brochures

  1. Multifuge

    58 Pages

  2. MaxQ 6000

    40 Pages

  3. 1300 Series A2

    76 Pages

  4. LTQ XL™

    4 Pages

  5. Furnaces

    2 Pages

  6. native MS

    16 Pages

  7. RM 200 EG

    4 Pages

  8. Darwin LIMS

    2 Pages

  9. Konelab 20

    2 Pages

  10. Indiko

    6 Pages