video corpo

Varioskan™ LUX

Varioskan™ LUX
1 / 54 PagesView full catalog

Varioskan™ LUX

Product catalog summary
Introduction
The Thermo Scientific Varioskan LUX is a versatile microplate reader supporting multiple measurement technologies such as absorbance, fluorescence intensity, luminescence, AlphaScreen, and time-resolved fluorescence. It operates in the UV/Vis/NIR range and includes features like temperature control, plate shaking, and optional dispensers and gas control modules.
Installation
The installation involves several steps: removing the transport lock, installing the tray and adapter, setting up dispensers, connecting gas modules, and establishing power and USB connections. The instrument requires careful handling due to its weight (53-60 kg) and needs two people for lifting.
Operations
Operations include switching the instrument on/off, managing plate trays, setting temperatures up to 45°C, and using dispensers. The instrument supports both top and bottom fluorescence intensity measurements.
SkanIt Software
SkanIt Software is used for session management, protocol setup, and data analysis. It allows users to start measurements, view results, perform calculations, and generate reports. The software supports multiple languages and session saving.
Safety and Maintenance
Safety guidelines are crucial to prevent hazards and ensure optimal performance. Regular maintenance involves checking components and adhering to safety specifications. The instrument complies with the EU's WEEE Directive for recycling and disposal.
Detailed Installation Steps
1. Transport Lock Removal: Remove screws and store the transport lock tag.
2. Tray and Adapter Installation: Ensure proper alignment and secure fastening.
3. Dispenser Setup: Connect tubes and insert dispensing heads.
4. Gas Module Setup: Attach gas supply tubes and ensure proper ventilation.
5. Power and USB Connection: Ensure proper grounding.
6. Software Installation: Install SkanIt Software with administrator rights.
Plate Template and Adapter Association
Select appropriate plate templates and adapters for different plate formats, ensuring compatibility with the software.
LAT Module Filters Installation
Instructions for installing AlphaScreen, TRF, and luminescence emission filters include selecting filter positions and handling filters with care.
Gas Control
The Integrated Gas Module allows control of CO2 and O2 concentrations, with guidance on setting levels and connecting gas bottles safely.
Rules for Safe Use
Follow safety guidelines to avoid ultraviolet radiation, ensure proper assembly, and handle gas bottles safely.
Using SkanIt Software
The software interface includes tools for creating sessions, defining plate layouts, and viewing results. Protocol actions include measuring absorbance, fluorescence, and luminescence.
Measurement Procedures
Start kinetic absorbance measurements by naming and saving sessions. Results can be viewed in real-time and exported for further analysis.
Session Management
Sessions can be saved, opened, imported, and exported. The software supports importing sessions from older versions.
See more

Catalog excerpts

Varioskan™ LUX-1

Thermo Scientific Varioskan™ LUX User Manual SkanIt™ Software for Microplate Readers

 Open the catalog to page 1
Varioskan™ LUX-2

© 2020 Thermo Fisher Scientific Inc. All rights reserved. Manufacturer Life Technologies Holdings Pte. Ltd. (a part of Thermo Fisher Scientific Inc.) 33, Marsiling Industrial Estate Road 3, #7-06, Singapore 739256 Thermo Fisher Scientific Inc. provides this document to its customers with a product purchase to use in the product operation. This document is copyright protected and any reproduction of the whole or any part of this document is strictly prohibited, except with the written authorization of Thermo Fisher Scientific Inc. The contents of this document are subject to change without notice....

 Open the catalog to page 2
Varioskan™ LUX-3

WEEE Compliance This product is required to comply with the European Union’s Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96/EC. It is marked with the following symbol: Thermo Fisher Scientific has contracted with one or more recycling or disposal companies in each European Union (EU) Member State, and these companies should dispose of or recycle this product. Contact Thermo for further information on Thermo Fisher Scientific's compliance with these Directives and the recyclers in your country.

 Open the catalog to page 3
Varioskan™ LUX-5

P Preface About This Guide Thermo Scientific™ Varioskan™ LUX is a modular multi-technology microplate reader and it is controlled by Thermo Scientific SkanIt® Software for Microplate readers. This guide gives an overview of the instrument and software installation procedures, and describes the main operations and routine maintenance. Related Documentation In addition to this guide, Thermo Fisher Scientific provides the following electronic documents for Varioskan LUX and SkanIt Software: • Thermo Scientific™ Varioskan™ LUX Technical Manual (Cat. No. N16045) • Thermo Scientific™ SkanIt™ Software...

 Open the catalog to page 5
Varioskan™ LUX-6

Contacting Us For the latest information on products and services, visit our website at: www.thermofisher.com/platereaders Thermo Scientific Varioskan™ LUX User Manual Thermo Fisher Scientific

 Open the catalog to page 6
Varioskan™ LUX-7

C Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Safety and Special Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Contacting Us. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 7
Varioskan™ LUX-8

Main Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Application Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Session Tree. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Task Ribbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Select the Software Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Chapter 5 Using SkanIt Software. . ....

 Open the catalog to page 8
Varioskan™ LUX-9

1 Introduction to Varioskan LUX Thermo Scientific™ Varioskan™ LUX is a modular multi-technology microplate reader. Varioskan LUX is controlled by Thermo Scientific™ SkanIt™ Software for Microplate Readers. End point, kinetic, spectral and multipoint measurements can be carried out in the UV/Vis/NIR range from appropriate microplate formats. In fluorescence intensity, time-resolved fluorescence, luminescence and AlphaScreen™ measurements 6- to 1536-well plates can be used, and correspondingly 6- to 384-well plates in absorbance measurements. Figure 1. Thermo Scientific™ Varioskan™ LUX The instrument...

 Open the catalog to page 9
Varioskan™ LUX-10

Introduction to Varioskan LUX Intended Use • Monochromators are used in absorbance and fluorescence intensity measurements. • Filters are used in AlphaScreen and TRF measurements. • Most luminescence measurements do not require any wavelength selection. But if required, filters can be used. The LAT module has built-in excitation filters for TRF and AlphaScreen. The TRF and AlphaScreen (and luminescence) emission filters you need to install yourself. Note All measurement technologies, except AlphaScreen, allow spectral scanning measurements with monochromators. The instrument has an incubator...

 Open the catalog to page 10
Varioskan™ LUX-11

Introduction to Varioskan LUX Instrument Layout Instrument Layout The front view of the instrument. Figure 2. The power switch (1), LED indicator (2), dispenser sliding cover (3), front cover (4), and measurement chamber door (5). The back view of the instrument. Figure 3. Thermo Fisher Scientific The cooling fan outlets (1), USB connector (2), mains power supply connector (3), power switch (4), and gas connectors (5). Thermo Scientific Varioskan™ LUX User Manual

 Open the catalog to page 11
Varioskan™ LUX-12

Introduction to Varioskan LUX Instrument Layout The instrument with the dispenser sliding cover open. Figure 4. Plate In/Out button (1), LAT module (2), Prime and Empty buttons (3), dispensers 1 and 2 (4), reagent bottle holder (5). Thermo Scientific Varioskan™ LUX User Manual Thermo Fisher Scientific

 Open the catalog to page 12
Varioskan™ LUX-13

2 Install Varioskan LUX This chapter describes how to install the instrument. IMPORTANT The instrument weighs 53 - 60 kg (117 - 131 lbs.) and needs two persons to lift. Take into account the weight, safety and instrument requirements when deciding where to place the instrument. Installation For detailed environmental requirements, see the Thermo Scientific™ Varioskan™ LUX Technical Manual. IMPORTANT Do not touch or loosen any screws or parts other than those specified in the instructions. Place the instrument on a sturdy laboratory bench that can take the weight of the instrument. Installation...

 Open the catalog to page 13
Varioskan™ LUX-14

Install Varioskan LUX Installation Dispenser sliding cover (1). b. Remove the front panel by pulling the two bolts, one on each side at the bottom, sideways, then by turning the bottom of the cover 30°, and lifting it off. Figure 6. Side bolts (1), front panel (2). The metallic transport lock support is fastened with four screws. Two screws (1 and 2) are fastened to the tray holder, and two screws (3 and 4) are fastened to the track mechanism bar. c. Remove the tray holder screws (1 and 2), and the transport lock tag. Store the lock tag for future use. Thermo Scientific Varioskan™ LUX User Manual...

 Open the catalog to page 14

All Thermo Scientific catalogs and technical brochures

  1. CryoStar NX50

    2  Pages

  2. Multifuge

    58  Pages

  3. MaxQ 6000

    40  Pages

  4. 1300 Series A2

    76  Pages

  5. LTQ XL™

    4  Pages

  6. Furnaces

    2  Pages

  7. native MS

    16  Pages

  8. RM 200 EG

    4  Pages

  9. Darwin LIMS

    2  Pages

  10. Konelab 20

    2  Pages

  11. Indiko

    6  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.