This document is a compilation of technical drawings and revision histories related to various IDD (Inspection Door/Damper) frame and cover designs produced by THERMOD AB, Sweden. The drawings cover multiple configurations including two-sided and one-sided covers, stainless steel frames, and mounting options for walls and panels.

Main Sections

1. Drawing Specifications

  • Drawings are provided in A2 and A3 print formats with a consistent scale of 1:10.
  • Each drawing includes a unique drawing number (e.g., 010-011-00, 010-120-00) and revision number to track updates.
  • Designs include variations such as two-sided covers, one-sided covers, stainless steel frames, and mounting either on walls or panels.
  • Some drawings specify that certain formulas apply only to symmetrical leafs, indicating design constraints.

2. Change History and Revision Tracking

  • Each drawing contains a change history table documenting initial releases and subsequent modifications.
  • Key updates include gasket geometry changes (09-01-2012), addition of quick-release features on the frame (20-02-2012), and frame profile and accessory changes (2014).
  • Revisions are identified by revision numbers (e.g., 01, 02, 03, 04) and initials of responsible engineers (e.g., PB, AD, SK).

3. Contact and Company Information

  • THERMOD AB is located at Söderborgsvägen 32, SE-671 95 Klässbol, Sweden.
  • Contact details include telephone (+46 570 72 74 70), fax (+46 570 72 74 71), and email ([email protected]).

4. Design and Construction Notes

  • Drawings indicate mounting methods for wall or panel installation, highlighting flexibility in application.
  • Stainless steel frame versions are documented separately, with noted changes in frame construction and accessories.
  • Quick-release mechanisms have been added in later revisions to improve usability.

5. Technical Parameters and Limitations

  • Scale of 1:10 is consistently used for detailed visualization.
  • Formulas referenced are valid only for symmetrical leaf designs, implying limitations on asymmetrical configurations.

Summary of Critical Information

  • Design evolution is well documented through change history tables, ensuring traceability of modifications.
  • Multiple mounting options and cover configurations provide adaptability for different installation requirements.
  • Material variations (standard vs stainless steel) are clearly distinguished, with corresponding updates in frame construction.
  • Contact information is consistently provided for technical support and inquiries.

Overall, the document serves as a comprehensive technical reference for manufacturing, installing, and maintaining IDD frames and covers by THERMOD AB, emphasizing version control, design flexibility, and clear communication of technical changes.

See more

Catalog excerpts

Innerdoor ID / Wet room door / Hygiene door-1

CHANGE HISTORY TABLE

 Open the catalog to page 1
Innerdoor ID / Wet room door / Hygiene door-2

CHANGE HISTORY TABLE

 Open the catalog to page 2
Innerdoor ID / Wet room door / Hygiene door-3

CHANGE HISTORY TABLE

 Open the catalog to page 3
Innerdoor ID / Wet room door / Hygiene door-4

CHANGE HISTORY TABLE

 Open the catalog to page 4
Innerdoor ID / Wet room door / Hygiene door-5

CHANGE HISTORY TABLE

 Open the catalog to page 5
Innerdoor ID / Wet room door / Hygiene door-6

CHANGE HISTORY TABLE * formula valid only for symmetrical leafs Contact address THERMOD AB Soderborgsvagen 32 SE-671 95 Klassbol, Sweden tel (0)570 72 74 70 fax. (0)570 72 74 71 info@thermod se

 Open the catalog to page 6
Innerdoor ID / Wet room door / Hygiene door-7

CHANGE HISTORY TABLE * formula valid only for symmetrical leafs Contact address THERMOD AB Soderborgsvagen 32 SE-671 95 Klassbol, Sweden tel (0)570 72 74 70 fax. (0)570 72 74 71 info@thermod se

 Open the catalog to page 7
Innerdoor ID / Wet room door / Hygiene door-8

CHANGE HISTORY TABLE

 Open the catalog to page 8
Innerdoor ID / Wet room door / Hygiene door-9

CHANGE HISTORY TABLE Modification description 1. 01 Initial Release Contact address: Drawing name: Drawing number: ID, stainless frame, one sided cover, mounting for panel Date:

 Open the catalog to page 9
Innerdoor ID / Wet room door / Hygiene door-10

CHANGE HISTORY TABLE

 Open the catalog to page 10
Innerdoor ID / Wet room door / Hygiene door-11

CHANGE HISTORY TABLE Modification description 1. 01 Initial Release 2. 02 Frame construction change Contact address: Drawing name: Drawing number: ID, stainless frame, two sided cover, mounting for panel Date:

 Open the catalog to page 11
Innerdoor ID / Wet room door / Hygiene door-12

CHANGE HISTORY TABLE No Rev. Modification description 1. 01 Initial Release 2. 02 Frame profile and accessories change Contact address: Drawing name: Drawing number: ID, stainless frame, one sided cover, mounting for wall Date:

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.