1. Catalogs
  2. TopAir Systems, Inc.
  3. Ninhydrin / DFO Chamber

Ninhydrin / DFO Chamber

Ninhydrin / DFO Chamber

Ninhydrin / DFO Chamber

Product catalog summary
Overview: The Ninhydrin and DFO Chamber by TopAir Systems is designed to enhance latent fingerprint development on absorbent surfaces using agents like DFO, Ninhydrin, and Indandione. It operates in a controlled environment to optimize conditions such as moisture, temperature, and duration.
Specifications: The chamber supports Ninhydrin development at 80°C and 65% humidity, while DFO and Indandione are developed at 100°C in dry conditions. It features a high-quality metal construction with stainless steel interior, comprehensive insulation, and a double-glazed window for temperature stability.
Key Features:
  • Intuitive smart touchscreen for easy operation.
  • Precise temperature and humidity control with monitoring capabilities.
  • Timer countdown with alerts for cycle readiness and completion.
  • Three removable shelves and hanging clips for convenience.
  • Interior surface drying system and LED lighting for visibility.
  • External water filling port and viewing window for water level monitoring.
Control System: The TopAir Control System offers a 7-inch color touchscreen interface with features such as four language setup, clock and date display, metric/imperial measurement selection, critical alarms, cycle time display, and drying cycle management.
Design Features: Includes a warm air exhaust, advanced control system, and interior humidifier.
Additional Products: TopAir Systems also offers various other products including CA Chambers, Opioid Evidence Handling Workstations, Evidence Drying Cabinets, and Ductless Fume Hoods.
See more

Catalog excerpts

Ninhydrin / DFO Chamber-1

TOPAIR SYSTEMS PRODUCT LINE

 Open the catalog to page 1
Ninhydrin / DFO Chamber-2

The Ninhydrin, DFO and Indandione Chamber Cabinet by TopAir Systems accelerates latent fingerprint development on absorbent surfaces. It employs DFO, Ninhydrin, and other agents in a controlled environment to optimize efficacy by managing moisture, temperature (80°C for Ninhydrin, 100°C for DFO and Indandione in dry conditions), and duration. Operated via proprietary software, the chamber cabinet enables autonomous cycle initiation, parameter setting, and result retrieval. It features an intuitive touchscreen for easy programming of temperature, humidity, and operation time, with status notifications...

 Open the catalog to page 2
Ninhydrin / DFO Chamber-3

Key Features: • Intuitive smart touchscreen • Temperature and humidity monitoring • Precise temperature and humidity control • Timer countdown with alerts and reminders when a cycle is ready or finished • Three perforated, removable shelves • Hanging clips for added convenience • Interior surface drying system • LED lighting for enhanced visibility • Viewing window on the humidity cabinet for monitoring water levels • External water filling port Tel : 1-855-6-TOPAIR International: +1-855-686-7247 Email: [email protected] www.topairsystems.com I Headquarters: 300 First Avenue, Suite 102,...

 Open the catalog to page 3
Ninhydrin / DFO Chamber-4

*'0?Ninhydrin and DFO Chamber TopAir System’s Control System Say goodbye to manual control systems -Welcome to the era of streamlined efficiency with the revolutionary TopAir Control System. The advanced system consolidates dozens abilities into one intuitive touchscreen interface, revolutionizing the way you manage operations. With a touch of a finger, users can access the following features on the TopAir System’s 7-inch color touchscreen: • Four Language Setup: English, Spanish, French, Dutch • Clock and Date Display • Temperature and Humidity Display • Metric/Imperial System Measurement Selection...

 Open the catalog to page 4
Ninhydrin / DFO Chamber-5

With its user-friendly design, the TopAir Control System empowers you to optimize processes, increase productivity, and stay ahead in today's fast-paced environment. Four Language Setup Alorms Current date and time Dote 6> Time Year 2000 Month: 00 Day: 00 Maintainance Hour 00 Minute: 00 Clock and Date Display Regional settings Display units: Clock format Development parameters Chemical Temperature [celsius] Humidity (%] Tel : 1-855-6-TOPAIR International: +1-855-686-7247 Email: [email protected] www.topairsystems.com I Headquarters: 300 First Avenue, Suite 102, Needham, MA 02494 USA

 Open the catalog to page 5
Ninhydrin / DFO Chamber-6

Design Features: Advanced Control System

 Open the catalog to page 6
Ninhydrin / DFO Chamber-7

More From TopAir Systems: CA Chamber Various Water Filtered Downflow Dusting Workstation

 Open the catalog to page 7
Ninhydrin / DFO Chamber-8

More From TopAir Systems: TOPAIR SYSTEMS CA Chamber Carbon/ Water FIltration system Opioid Evidence Handling Workstation Ductless Fume Hood Evidence Drying Cabinet www.topairsystems.com Tel : 1-855-6-TOPAIR / International: +1-855-686-7247 Headquarters: 300 First Avenue, Suite 102, Needham, MA 02494 USA Email: [email protected]

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.