Brochure Topcon 3D OCT 2000 Series
14Pages

{{requestButtons}}

Catalog excerpts

Brochure Topcon 3D OCT 2000 Series - 1

Optical Coherence Tomography CONNECTING VISIONS

Open the catalog to page 1
Brochure Topcon 3D OCT 2000 Series - 2

Fast, Easy, and Precise Unveiling Topcon 3D OCT-2000 Full Line-up of Spectral Domain OCTs with High Resolution Fundus Cameras

Open the catalog to page 2
Brochure Topcon 3D OCT 2000 Series - 3

3D OCT-2000 series was designed to meet the needs of all eye care professionals The 3D OCT-2000 series of spectral domain OCT'S was designed to meet the needs of all eye care professionals- from the single doctor practice to a large university hospital there is a model of the 3D OCT-2000 to meet everyone's needs. ■> OCT, Color, Red-free (Digital), FA , FAF images acquirable » OCT, Color, Red-free (Digital) images acquirable

Open the catalog to page 3
Brochure Topcon 3D OCT 2000 Series - 4

50,000 A-scans/sec provides greater detail in a shorter period of time The enhanced 50,000 A-scans/sec allows for faster tomography acquisition and minimizes artifacts generated by eye movements, producing clear cross-sectional retinal images. The new analysis mode reduces processing time by 50%. Topcon's "Enhanced Choroidal Mode" visualizes further internal structures, allowing much superior visualization of

Open the catalog to page 4
Brochure Topcon 3D OCT 2000 Series - 5

High resolution retinal camera produces stunningly detailed images OCT, Color, Red-free (Digital), FA, FAF image? can be generated from a single unit. Camera settings can be customized to provide your preference of fundus images. If only the OCT image is required, simply select "Color

Open the catalog to page 5
Brochure Topcon 3D OCT 2000 Series - 6

CUSTOMER SATISFACTION Easy touch panel The monitor screen is a touch panel. The monitor displays information, operations by touching its screen. Auto functions » Color fundus photography Auto focus / Auto shoot Auto focus / Auto Z&Z lock / Auto polarization Auto center detection If the fovea is slightly off center after performing a 3D(V) scan of the macula the fovea to ensure accurate reporting and serial monitoring of the Image during

Open the catalog to page 6
Brochure Topcon 3D OCT 2000 Series - 7

IR tracking utilizes the IR image during capture to overlap exactly trie same place of trie retina. If the scanned areas moves, the escanning function will automatically begin. / Rescanning Function occur during image acquisition and this fixation problem can be the reason for major artifacts. To minimize this influence, "Motion Correction / Compensation / Rescanning Functions" e activated when capturing. » Compensation Function Tracks ocular and scans 7X7mm are, then compensates X direction » Rescanning Function Y direction movement can sometimi miss scanning area. In such case, the...

Open the catalog to page 7
Brochure Topcon 3D OCT 2000 Series - 8

ANALYZED DATA CAN BE EASILY OBTAINED AND UNDERSTOOD FROM RICH REPORT TEMPLATES Glaucoma Analysis (Macula) detects and analyzes ft NFL 8 GCL+IPL If NFL+GCL+IPL at macula Thickness map: Provides thickness of analyzed area with a color scale. Significance map: The thickness results can be compared with normative database over the KMO grid area on Red-free image. Average data: Thickness of Total / Superior / Inferior average can be Asymmetry map: Produces a differential value of the superior and inferior Color fundus/NFL thickness map/OCT images/ Cup and Disc ratio can be generated and compared...

Open the catalog to page 8
Brochure Topcon 3D OCT 2000 Series - 9

Optic disc analysis The above image is an example of a standard glaucoma analysis and report. The cup and disc margin can be manually adjusted to ensure accurate results. » Disc margin automatically determines Using a horizontal line between the edges of the RPE edges as a reference point, the software creates a line 120 |im above the line between the edges of RPE. The Cup margin will be determined at the cross points of the reference plane Drusen analysis Drusen counts / area / volume can be displayed. Drusen counts are described on the color fundus image and report, and are color-coded...

Open the catalog to page 9
Brochure Topcon 3D OCT 2000 Series - 10

FA/FAF PHOTOGRAPHY: TOPCON IMAGING TECHNOLOGY AHEAD OF ITS TIME

Open the catalog to page 10
Brochure Topcon 3D OCT 2000 Series - 11

HIGH RESOLUTION ANTERIOR CHAMBER SCANNING

Open the catalog to page 11
Brochure Topcon 3D OCT 2000 Series - 12

Topcon 3D OCT-2000 and its viewing software plays a powerful role in the management of the patient's data. The unique software enables all patient imaging and data to be collected, saved and reviewed remotely through one unified network, IMAGEnet™. OCT images can be viewed and analyzed through the network at any location; medical meet ngs. surgical simulot on in the operating room and in a patient consultation room. Furthermore, an integrated IMAGEnet"" system allows all clinical images taken throughout the ophthalmology department to be stored in one paLieir. file, thereby facilitating...

Open the catalog to page 12
Brochure Topcon 3D OCT 2000 Series - 13

Clinical images Case 2: 75-year-old, Male, AMD (Age-related macular degeneration) » Case 3: 82-year-old, male, BRVO (Branch retinal vein occlusion)

Open the catalog to page 13
Brochure Topcon 3D OCT 2000 Series - 14

KaOtfcáakaUL&á TteUitVfttds DilWSgnt JfitOisism SfCEtau&an Dl^nU^K BsMlnj Bòli =K L ■ íTusnasáSi— ssss*fc. — ■ Ü""ÍS&™Í~ i

Open the catalog to page 14

All Topcon Europe Medical catalogs and technical brochures

  1. SL-2G

    4 Pages

  2. TRC-NW400

    8 Pages

  3. IC-1 Series

    5 Pages

  4. SL-D701

    1 Pages

  5. VT-10

    4 Pages

  6. CV-5000PRO

    8 Pages

  7. Henson 9000

    2 Pages

  8. MPS II

    2 Pages

  9. SL SCAN-1

    12 Pages

  10. Topcon SL 3G

    4 Pages

  11. LENTIS Tplus

    2 Pages

  12. SP-3000P

    6 Pages

  13. SL-3G

    4 Pages

  14. AIT-16

    1 Pages

  15. IS-500E

    4 Pages

  16. IS-600N

    4 Pages

  17. Topcon ACP 8

    4 Pages

  18. CC-Series

    6 Pages

  19. CC-100XP

    2 Pages

  20. ACP-8

    4 Pages

  21. ALE-5100

    8 Pages

  22. ATE-800

    2 Pages

  23. ATE-600_650

    2 Pages

  24. IS-775

    8 Pages

  25. IS-700

    6 Pages

  26. IS-600II

    6 Pages

  27. Topcon OM

    4 Pages

Archived catalogs