DRI OCT-1, Atlantis swept source OCT
9Pages

{{requestButtons}}

Catalog excerpts

DRI OCT-1, Atlantis swept source OCT - 2

" We developed our understanding of retinal diseases based on what we have been able to see, but imperfect visualization can yield only imperfect knowledge. Most major advances in our understanding of retinal diseases were preceded by advances in imaging. Improving our imaging of the choroid and deeper structures will illuminate a path to a new frontier of knowledge." Vitreous-Retina-Macula Consultants of New York Deep Range Imaging OCT

Open the catalog to page 2
DRI OCT-1, Atlantis swept source OCT - 3

DEEP RANGE IMAGING Topcon OCT, the ultimate product chosen by professionals Courtesy of Dr. R. F. Spaide and Dr. I. A. Barbazetto, Vitreous-Retina-Macula Consultants of New York “This patient had toxoplasmosis retinochoroiditis with cellular inltrates in the vitreous. The advantage of swept source OCT is the tremendous ability to visualize every level of involvement. The cells in the vitreous, the retinal thickening with loss of laminations, and the choroidal thickening associated with the retinochoroiditis are all clearly demonstrated in a single scan.” DRI OCT-1 allows photography of...

Open the catalog to page 3
DRI OCT-1, Atlantis swept source OCT - 4

CASE REPORTS Acquired pit in the optic disc area of highly myopic eye Courtesy: Department of Ophthalmology, Osaka University Graduate School of Medicine Lateral: 6 mm Courtesy: Department of Ophthalmology, Tokyo Medical and Dental University Dome-shaped macula Age-related macular degeneration with sub-retinal hemorrhage and retinal pigment epithelial detachment Courtesy: Department of Ophthalmology, Fukushima Medical University Courtesy: Department of Ophthalmology and Visual Sciences, Kyoto University Hospital

Open the catalog to page 4
DRI OCT-1, Atlantis swept source OCT - 5

- DEEP RANGE IMAGING - DEEP RANGE IMAGING TOPCON has developed a new Swept Source OCT with 1,050nm wavelength with the world’ s fastest* DRI OCT-1 displays detail structures of not only retina but choroid and even sclera- irrespective of the scanning speed of 100,000A-scans/sec. Utilizing this 1,050nm wavelength, DRI OCT-1 can penetrate opaque media. With the capability of imaging deeper anatomic structures with less inuence in deeper, visualizing ocular tissues such as choroid or even sclera within an incredibly short time as well scattering, DRI OCT-1 can visualize the entire tomogram...

Open the catalog to page 5
DRI OCT-1, Atlantis swept source OCT - 6

IMAGING FUNCTION Easy Capture 12mm Wide Scan The increased scan coverage of the macular area to disc afforded by the 12mm wide scan may be useful for the evaluation of abnormalities observed in a broader area. Furthermore an instant single shot of the 12mm wide area will reduce patient fatigue and tremendously enhance examination workow. Indulge yourself with what you can see now. Register / Select Patient When registering a patient, patient ocular parameters can be inputted. Using the patient ocular parameters information, the software compensates the circle diameter during the circle...

Open the catalog to page 6
DRI OCT-1, Atlantis swept source OCT - 7

ANALYSIS FEATURE 7 Layers Segmentation 7 Layers Thickness Map Caliper Function 3D Volume Rendering The captured 3D image can be magnied / narrowed, rotated, cropped, sliced and peeled to any x, y, z direction. Advanced layer detection algorithms and noise reduction software enables the ability to detect 7 different layers of the retina. Thickness map and caliper functions allow for detailed analysis of the desired layer. Line 1 - Line 5 Peeling Import Function Follow-up Examination & Comparison Function Color / FA / FAF images can be imported and compared with OCT images. By simply by...

Open the catalog to page 7
DRI OCT-1, Atlantis swept source OCT - 8

SPECIFICATIONS Scan Pattern Example Observation & photography of fundus Scan Mode Picture Angle Operating Distance Photographable Diameter of Pupil Scan Pattern Small pupil diameter: 3.3mm or more Maximum Scan Resolution Maximum Overlapping Scan Count Maximum Scan Length (mm) 129 Observation & photography of fundus tomogram Scan Range Fundus Image Resolution (on Fundus) Scan Speed Scan Patterns 3D scan (horizontal / vertical) Linear scan (Line-scan/Cross-scan/Radial-scan) * More variable scan patterns available with a combination of different resolution, overlapping scan count and scan...

Open the catalog to page 8
DRI OCT-1, Atlantis swept source OCT - 9

* PC and Camera sold seperately. Subject to change in design and/or specifications without advanced notice. IMPORTANT the terms of the Export Administration Regulation of the In compliance with In order to obtain the best available in some regions or countries. United States of America,this product may not beresults with this instrument, please be sure to review all user instructions prior to operation. Topcon España S.A. Topcon Deutschland GmbH Essebaan 11; 2908 LJ Capelle a/d IJssel; P.O. Box 145; 2900 AC Capelle a/d IJssel; The Netherlands Phone: +31-(0)10-4585077; Fax: +31-(0)10-4585045...

Open the catalog to page 9

All Topcon Europe Medical catalogs and technical brochures

  1. SL-2G

    4 Pages

  2. TRC-NW400

    8 Pages

  3. IC-1 Series

    5 Pages

  4. SL-D701

    1 Pages

  5. VT-10

    4 Pages

  6. CV-5000PRO

    8 Pages

  7. Henson 9000

    2 Pages

  8. MPS II

    2 Pages

  9. SL SCAN-1

    12 Pages

  10. Topcon SL 3G

    4 Pages

  11. LENTIS Tplus

    2 Pages

  12. SP-3000P

    6 Pages

  13. SL-3G

    4 Pages

  14. AIT-16

    1 Pages

  15. IS-500E

    4 Pages

  16. IS-600N

    4 Pages

  17. Topcon ACP 8

    4 Pages

  18. CC-Series

    6 Pages

  19. CC-100XP

    2 Pages

  20. ACP-8

    4 Pages

  21. ALE-5100

    8 Pages

  22. ATE-800

    2 Pages

  23. ATE-600_650

    2 Pages

  24. IS-775

    8 Pages

  25. IS-700

    6 Pages

  26. IS-600II

    6 Pages

  27. Topcon OM

    4 Pages

Archived catalogs