DRI OCT Triton Series
24Pages

{{requestButtons}}

Catalog excerpts

DRI OCT Triton Series - 1

A TOPCON ADVANCED DIAGNOSIS SOLUTION Triton Series Maestro 3D Optical Coherence Tomography Swept SourceOptical Coherence Tomography

Open the catalog to page 1
DRI OCT Triton Series - 2

The best just became better: TOPCON’s new dimension of OCT technology. See, Discover, Explore TOPCON Swept Source OCT with multi-modal fundus imaging.

Open the catalog to page 2
DRI OCT Triton Series - 3

Swept Source OCT with multi-modal fundus imaging New Dimension of OCT Imaging: DRI OCT Triton Swept Source OCT » More confident initial diagnosis and ability to track change over time – Deep scanning and high-resolution TOPCON swept source technology, penetrates cataract and hemorrhage, providing more information for better patient care. » Greater clinical efficiency – Next generation SMARTTrackTM eye tracking combined with ultra-fast swept source technology maximizes data quantity to give a truer record of your patient’s eye while minimizing image acquisition time. » reater patient comfort...

Open the catalog to page 3
DRI OCT Triton Series - 4

Our third generation OCT technology TOPCON OCT legacy In 2006 TOPCON was the first company to introduce the commercial Spectral Domain (SD) OCT. Spectral Domain had many advantages over Time Domain OCT. The first SD OCT of the TOPCON line was the TOPCON 3D OCT-1000, which was the world’s first instrument to incorporate a true color fundus camera, which proved to be a valuable tool alongside OCT analysis. In 2009 TOPCON introduced the next model, the 3D OCT-2000 and the 3D OCT-2000 FA / FAplus which converted the OCT into a unique multi-modal tool for OCT imaging, color fundus images, FA and...

Open the catalog to page 4
DRI OCT Triton Series - 5

Deep range imaging Swept Source OCT deep range imaging Swept Source technology & 1,050nm wave length Swept source OCT provides a significant improvement over conventional OCT. Due to the optimized long wavelength scanning light (1,050nm), there is better penetration of the deeper layers of the eye. Furthermore, this scanning light also penetrates better through cataracts, hemorrhages, blood vessels and sclera. scanning speed 100,000 A-Scans/second Approximately twice higher scan speed*5 will bring more scans for a single B scan image, and more informative image supports efficiency and...

Open the catalog to page 5
DRI OCT Triton Series - 6

Swept Source OCT Explore & analyze See, Discover, Explore Accurate choroidal thickness maps DRI OCT Triton offers a unique combination of anterior & For the first time, accurate high speed choroidal posterior OCT imaging. In both cases detailed structures thickness maps can be produced; which is crucial, not only are revealed. With DRI OCT Triton you can scan a large for early disease recognition, but also for the monitoring area of the eye with wide-field OCT patterns such as the of inflammatory abnormalities. The choroid reveals 12 X 9mm scan or the 16mm anterior scan. valuable...

Open the catalog to page 6
DRI OCT Triton Series - 7

Gather more data En Face OCT imaging* En Face imaging allows for independent dissection of the vitreoretinal interface, retina, Retinal Pigment Epithelium (RPE), and choroid, and uniquely projects these layers so that macular pathology throughout the posterior pole can be studied and correlated with a patient’s symptoms, their abnormality, and its progression. * optional software Original image Flattened image Lamina cribrosa EVV (Enhanced Vitreous Visualization™) Enhanced vitreous visualization with DRI OCT Triton helps assess the natural history and treatment response in vitreoretinal...

Open the catalog to page 7
DRI OCT Triton Series - 8

5 in 1 diagnostic tool See, Discover, Explore the ultimate 5-in-1 instrument Multi modal fundus imaging The DRI OCT Triton offers a true color, non mydriatic fundus image while using a very low intensity flash. This unique feature is a perfect tool for identifying the location of scans in the eye utilizing TOPCON’s patented Pinpoint RegistrationTM. The DRI OCT Triton Plus offers a wide range of diagnostic options with multi-modal color fundus imaging, Fluorescein Angiography (FA) and Fundus Autofluorescence (FAF) for even more diagnostic possibilities*1. For the first time Pinpoint...

Open the catalog to page 8
DRI OCT Triton Series - 9

High quality imaging Import function High quality true fundus images Color / FA / FAF / Indocyanine Green Angiography (IA) The resolution and contrast of the retinal images has been images can be imported with an OCT scan captured at specifically tuned to give a natural appearance. a selected location on the image. By double-clicking a specific point on the OCT image or the imported photograph, the location will be indicated on both images with a green cross. Comparison across a range of imaging modalities may better enhance understanding of disease pathophysiology. Images taken in the...

Open the catalog to page 9
DRI OCT Triton Series - 10

Best solution for your workflow New tracking system - SMARTTrackTM NEW SMARTTrackTM is a very useful tool to compensate for the ever present involuntary eye movements (microsaccades). Lock on to the OCT scan line SMARTTrackTM allows the automatic acquisition of a follow-up scan in precisely the same anatomical location. SMARTTrackTM enhances the user-friendliness of the machine. » undus Guided Acquisition F Fundus Guided Acquisition (FGA) The DRI OCT Triton simultaneously acquires an OCT and fundus image. With FGA the operator can choose to take a fundus image (or import an image), select...

Open the catalog to page 10
DRI OCT Triton Series - 11

Ease of use Follow-up function For accurate diagnosis and time savings at subsequent visits, the follow-up function is a vital tool for retrieving and re-analyzing the same anatomical location. Follow-up icon (sample) Motion correction DRI OCT Triton is equipped with an advanced motion correction tool that can compensate for eye movement in all 3 dimensions. In part, this motion is corrected with an automatic rescanning function, saving time for the operator. Before compensation After compensation OCT capture mode without retinal photography DRI OCT Triton has the option of capturing a 3D...

Open the catalog to page 11
DRI OCT Triton Series - 12

Detailed Comprehensive Reports Rich scan protocols A wide range of scan patterns is clearly laid out, allowing the operator to quickly select the correct pattern. 3D: Macula 3D: Optic disc 3D Wide (H) FGA mode Combination Combination Combination Fundus Photo Stereo. Radial: scan: scan: scan: Fundus Photo Anterior Line Radial 5 Line Cross segment » Combination scan This new scan pattern provides both 3D wide scan (12mm x 9mm) and Line / 5 line cross / radial scan. Previous OCT models do not offer the option to capture B scan and 3D images at the same time. The new combination scan provides a...

Open the catalog to page 12

All Topcon Europe Medical catalogs and technical brochures

  1. SL-2G

    4 Pages

  2. TRC-NW400

    8 Pages

  3. IC-1 Series

    5 Pages

  4. SL-D701

    1 Pages

  5. VT-10

    4 Pages

  6. CV-5000PRO

    8 Pages

  7. Henson 9000

    2 Pages

  8. MPS II

    2 Pages

  9. SL SCAN-1

    12 Pages

  10. Topcon SL 3G

    4 Pages

  11. LENTIS Tplus

    2 Pages

  12. SP-3000P

    6 Pages

  13. SL-3G

    4 Pages

  14. AIT-16

    1 Pages

  15. IS-500E

    4 Pages

  16. IS-600N

    4 Pages

  17. Topcon ACP 8

    4 Pages

  18. CC-Series

    6 Pages

  19. CC-100XP

    2 Pages

  20. ACP-8

    4 Pages

  21. ALE-5100

    8 Pages

  22. ATE-800

    2 Pages

  23. ATE-600_650

    2 Pages

  24. IS-775

    8 Pages

  25. IS-700

    6 Pages

  26. IS-600II

    6 Pages

  27. Topcon OM

    4 Pages