Catalog excerpts

Retinal Camera CONNECTING VISIONS
Open the catalog to page 1
The Gold Standard in Retinal Imaging TRC-50DX: Leading the way in retinal cameras. In the rapidly developing technology of digital cameras, retinal imaging techniques advance quickly towards higher resolution and newer methods. New diagnostic modes and procedures require versatility, precision and reliability more than ever before. The Topcon TRC-50DX, as well as the TRC-50DX(Type IA), improves on the unsurpassed quality of Topcon retinal cameras, incorporating new functions that enhance their versatility and operational ease. The camera can be used with a variety of photo devices, from...
Open the catalog to page 2
Retinal camera TRC-50DX / DX (Type IA) A newly developed control panel, equipped with a touchscreen, allows for a quick and easy change of settings while the Small Aperture function facilitates focusing and enhances sharpness. Further enhancing its adaptability, the TRC-50DX(Type IA) can perform Auto Fluorescence studies, expanding its diagnostics aptitudes and application availability. An adaptable filter mechanism lets the user add or exchange filters of his or her choice for different procedures or research projects.
Open the catalog to page 3
Features Auto Fluorescence This new diagnostic technique allows for a more in-depth study of the Retinal Pigment Epithelium (RPE) without the need of an injection of a contrast media, enhancing patient comfort and cooperation. This feature is available as the default component in TRC-50DX type IA. Red Free Auto fluorescence Split Image Focusing This convenient feature minimizes out-of-focus images and allows even less experienced operators to obtain clear, sharp images with minimal effort. Compact Design Minimized design helps to check patient's reaction and to open eye beyond the unit....
Open the catalog to page 4
Retinal camera TRC-50DX / DX (Type IA) Touch Panel Control Designed with user convenience in mind, the TRC-50DX features a Touch Panel control that allows the operator to change the camera settings with a single touch. All adjustments are at the photographer's fingertips. Small pupil mode - The S■ rirjII ¡)ii;¡il mode pern :% ri :icinq Ihiough pi p h ,¡s in.ill :r, 4.5,nir: Aperture adjustment - : he Snoil ' :c::ing o" :he soc-.urc orod^ces ; sharper. Msior to "ocus m: wil- enhanced duplr ':/ :ield. II offers remarkable effect in peripheral photography. Furthermore, its enhanced range of...
Open the catalog to page 5
Optional Accessories Relay Lens OR-2 (1X Relay Lens) Double Mount TV Relay Lens The OR-2 enables conventional color photography and fluorescein angiography on film. Various double relay lenses meet the requirement of attaching CCD cameras to the top part. Triple Mount TV Relay Lens Single Mount TV Relay Lens Triple mount TV relay lenses enable integration of 3 CCD cameras to the top part. Single mount TV relay lenses make up simple and economical systems for color photography and fluorescein angiography. Retinal camera TRC-50DX: 35mm Film Camera OR-2 1X Relay Lens Triple Mount TV Relay Lens...
Open the catalog to page 6
Retinal camera TRC-50DX / DX (Type IA) IMAGEnet i-baseTM Digital Imaging System Using comprehensive software for capturing, processing, archiving and consulting, IMAGEnet I-base expands the abilities of the TRC-50DX into a digital imaging analysis system for clinical applications. IMAGEnet I-base detects the filter settings and CCD camera in use from the TRC-50DX and sets the capture screen to the corresponding procedure automatically. PDT Auto Mosaic A variety of options conveniently priced fit the needs of the single practitioner or the multi-discipline health institution with powerful...
Open the catalog to page 7
Specifications Capture mode Auto Fluorescence Angle of Coverage Photographic Magnifications Working Distance TRC-50DX Color/Red-Free/FA OPTION* TRC-50DX (type IA) Color/Red-Free/FA/ICG/Auto Fluo O 50˚/35˚/20˚ With 35mm camera at zero diopter; 1.84x at 50˚, 2.45x at 35˚, 4.28x at 50˚ 39 mm 0 -10D~+6D - -23D~-9D Diopter Compensation Range for patient's eye + +5D~+23D A +22D~+41D -6D~+5D O˚ Diopter Compensation at finder Split Focus Internal Fixation Counter Optical Head tilt Light Source Power supply Power Consumption Dimensions / Weight Option* O O˚ Up 15˚ / Down 10˚ For photography: Max...
Open the catalog to page 8All Topcon Europe Medical catalogs and technical brochures
-
SL-2G
4 Pages
-
TRC-NW8 SERIES
8 Pages
-
TRC-NW400
8 Pages
-
IC-1 Series
5 Pages
-
DRI OCT Triton series
11 Pages
-
SL-D701
1 Pages
-
Endpoint Management
3 Pages
-
KR-1W, wavefront analyser
2 Pages
-
IS-600III, Instrument stand
5 Pages
-
ATE-600 / ATE-650
2 Pages
-
EZ-200 Advance, lensmeter
2 Pages
-
LM-8, lensmeter
4 Pages
-
ACP-8EM, Chart Projector
4 Pages
-
VT-10
4 Pages
-
CV-5000PRO
8 Pages
-
KR-1, kerato- refractometer
5 Pages
-
Henson 9000
2 Pages
-
MPS II
2 Pages
-
SP-1P, Specular microscope
8 Pages
-
ALADDIN, Biometer
7 Pages
-
Fundus Viewer System
2 Pages
-
SL SCAN-1
12 Pages
-
Topcon SL 3G
4 Pages
-
TRC NW400 brochure Topcon
5 Pages
-
Leaflet TRC 50DX
8 Pages
-
Topcon Brochure DRI OCT 1
9 Pages
-
IC-1, Instrument Column
2 Pages
-
LENTIS Tplus
2 Pages
-
OMS-90, operation microscope
4 Pages
-
CL-300, lensmeter
2 Pages
-
SP-3000P
6 Pages
-
OM-4, ophtalmometer
4 Pages
-
SL-3G
4 Pages
-
LENSAR Laser System
4 Pages
-
AIT-16
1 Pages
-
IS-500E
4 Pages
-
IS-600N
4 Pages
-
IS-600 III Topcon brochure
8 Pages
-
Topcon_brochure_IS-1
9 Pages
-
PASCAL Streamline 577
2 Pages
-
PASCAL Streamline
2 Pages
-
Patient_Brochure
7 Pages
-
LENTIS Comfort
2 Pages
-
Topcon Brochure Aladdin
4 Pages
-
Topcon LM8 8C
4 Pages
-
Topcon EZ 200 advance
2 Pages
-
Topcon_Brochure CL 100
4 Pages
-
Topcon ACP 8
4 Pages
-
Topcon brochure VT 10
4 Pages
-
Topcon CV-5000
8 Pages
-
Topcon_KR1 W Whitepaper
3 Pages
-
Topcon flyer KR 1W
2 Pages
-
Topcon_KR-1_brochure
5 Pages
-
CC-Series
6 Pages
-
CC-100XP
2 Pages
-
ACP-8
4 Pages
-
ALE-5100
8 Pages
-
ATE-800
2 Pages
-
ATE-600_650
2 Pages
-
IS-775
8 Pages
-
IS-700
6 Pages
-
IS-600II
6 Pages
-
Topcon TRC NW7SF
6 Pages
-
Topcon TRC NW300
2 Pages
-
Topcon SL SCAN 1 en
12 Pages
-
Topcon 3D OCT 2000
14 Pages
-
Topcon OM
4 Pages
Archived catalogs
-
DRI OCT Triton Series
24 Pages