Topcon TRC NW300
2Pages

{{requestButtons}}

Catalog excerpts

Topcon TRC NW300 - 1

Non-Mydriatic Retinal Camera TRC-NW300 Specifications Fixation target In accordance with the requirements for diabetic screening, the TRC-NW300 offers central, nasal and temporal targets. The Optic Disc, the Macula and the Fovea can be specifically positioned for diagnostic photography. An external fixation target is optionally available for added flexibility. Picture angle Working distance Photographable area of pupil Focus range to correct the refractive errors of the patient’s eye Internal fixation target Auto focus function Base movement Optic Disc “D” Center “C” Fovea“F” Chinrest movement Dimensions Weight 45° 40.7mm 4.0mm or more (Ø3.3mm or more when the small pupil diaphragm is used) 0 : -13D to +12D1 – : -33D to -12D + : +9D to +40D Center : Fixed 4 points Temporal side : Fixed 1 point Nasal side : Fixed 1 point Right / left eye automatic detection Used only in the split line working range ( This can be turned ON / OFF ) Back-forth : 46mm Right-left : 100mm U p-down : 30mm 67mm 274mm(W) × 508mm(D) × 528-558mm(H) 22.7kg *1 Split line working range Data storage and transmission Thanks to the Windows operating system incorporated in the TRCNW300, images can be viewed and stored instantly on an USB memory stick or CF card. Optional Accessory System Chart IMAGEnet i-base Using comprehensive software for capturing, processing, archiving and consulting, IMAGEnet i-base systems expand the clinical applications of the TRC-NW300. External Fixation Target Subject to change in design and/or specifications without advanced notice. In order to obtain the best results with this instrument, please be sure to review all user instructions prior to operation. Direct Printout The TRC-NW300 has the added feature of direct printout to a digital printer (with the use of PictBridge, and some models of USB) without the need for an external computer. This feature improves portability of the instrument. Topcon España S.A. Topcon Deutschland GmbH Topcon (Great Britain) Ltd. Essebaan 11; 2908 LJ Capelle a/d IJssel; P.O. Box 145; 2900 AC Capelle a/d IJssel; The Netherlands Phone: +31-(0)10-4585077; Fax: +31-(0)10-4585045 E-mail: medical@topcon.eu; www.topcon.eu HEAD OFFICE; Frederic Mompou, 4; 08960 Sant Just Desvern; Barcelona, Spain Phone: +34-93-4734057; Fax: +34-93-4733932 E-mail: medica@topcon.es; www.topcon.es Hanns-Martin-Schleyer Strasse 41; D-47877 Willich, Germany Phone: (+49) 2154-885-0; Fax: (+49) 2154-885-177 E-mail: med@topcon.de; www.topcon.de Topcon House; Kennet Side; Bone Lane; Newbury Berkshire RG14 5PX; United Kingdom Phone: +44-(0)1635-551120; Fax: +44-(0)1635-551170 E-mail: medical@topcon.co.uk; www.topcon.co.uk Topcon Danmark Topcon Italy Topcon Portugal Topcon Ireland Praestemarksvej 25; 4000 Roskilde, Danmark Phone: +45-46-327500; Fax: +45-46-327555 E-mail: info@topcondanmark.dk www.topcondanmark.dk Viale dell’ Industria 60; 20037 Paderno Dugnano, (MI) Italy Phone: +39-02-9186671; Fax: +39-02-91081091 E-mail: topconitaly@tiscali.it; www.topcon.it Rua da Forte, 6-6A, L-0.22; 2790-072 Carnaxide; Portugal Phone: +351-210-994626; Fax: +351-210-938786 www.topcon.pt Unit 276, Blanchardstown; Corporate Park 2 Ballycoolin; Dublin 15, Ireland Phone: +353-18975900; Fax: +353-18293915 E-mail: medical@topcon.ie; www.topcon.ie Topcon Scandinavia A.B. Topcon S.A.R.L. Topcon Polska Sp. z o.o. Neongatan 2; P.O. Box 25; 43151 Mölndal, Sweden Phone: +46-(0)31-7109200; Fax: +46-(0)31-7109249 E-mail: medical@topcon.se; www.topcon.se HEAD OFFICE; 89, rue de Paris; 92585 Clichy, France Phone: +33-(0)1-41069494; Fax: +33-(0)1-47390251 E-mail: topcon@topcon.fr; www.topcon.fr ul. Warszawska 23; 42-470 Siewierz; Poland Phone: +48-(0)32-670-50-45; Fax: +48-(0)32-671-34-05 www.topcon-polska.pl TOPCON CORPORATION 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan. Phone: 3-3558-2523/2522 Fax: 3-3960-4214 www.topcon.co.jp Item code: 5250411 / printed in Europe / 04.10 Topcon Europe Medical B.V. CONNECTING VISIONS

Open the catalog to page 1
Topcon TRC NW300 - 2

Ease of use combined with high image quality Topcon reaches yet another milestone for ophthalmic instrumentation with the introduction of the TRC-NW300 NonMydriatic Retinal Camera. Built upon more than 40 years of experience in the manufacturing of retinal cameras, this modern instrument combines a simple method of image capture with superior image quality, by means of our unique 8 megapixel CCD camera. Simple to use! All-in-One Design Easy alignment All-in-one design Alignment is easily accomplished by simply overlapping two bright spots on the monitor. The operator remains in control of...

Open the catalog to page 2

All Topcon Europe Medical catalogs and technical brochures

  1. SL-2G

    4 Pages

  2. TRC-NW400

    8 Pages

  3. IC-1 Series

    5 Pages

  4. SL-D701

    1 Pages

  5. VT-10

    4 Pages

  6. CV-5000PRO

    8 Pages

  7. Henson 9000

    2 Pages

  8. MPS II

    2 Pages

  9. SL SCAN-1

    12 Pages

  10. Topcon SL 3G

    4 Pages

  11. LENTIS Tplus

    2 Pages

  12. SP-3000P

    6 Pages

  13. SL-3G

    4 Pages

  14. AIT-16

    1 Pages

  15. IS-500E

    4 Pages

  16. IS-600N

    4 Pages

  17. Topcon ACP 8

    4 Pages

  18. CC-Series

    6 Pages

  19. CC-100XP

    2 Pages

  20. ACP-8

    4 Pages

  21. ALE-5100

    8 Pages

  22. ATE-800

    2 Pages

  23. ATE-600_650

    2 Pages

  24. IS-775

    8 Pages

  25. IS-700

    6 Pages

  26. IS-600II

    6 Pages

  27. Topcon OM

    4 Pages

Archived catalogs