Medical Equipment Pump Solution

Medical Equipment Pump Solution

Medical Equipment Pump Solution

Product catalog summary
Overview of In Vitro Diagnostics (IVD)
In Vitro Diagnostics (IVD) involves tests on human samples like blood and tissues to gather clinical diagnostic information. The industry encompasses various sectors, including immunodiagnostics, clinical chemistry, molecular diagnostics, microbiology diagnostics, blood diagnostics, and point-of-care testing (POCT).
Micro DC Pumps in IVD
Micro pumps are vital in IVD systems for tasks such as sample delivery, waste removal, and cleaning. They are crucial in processes like needle cleaning, cuvette washing, and maintaining constant temperature circulation. TOPSFLO micro pumps are noted for their effectiveness in these applications.
Diaphragm Pumps
Diaphragm pumps are extensively used in IVD instruments for waste removal and cleaning. They can either directly pump out waste liquids or create a vacuum to draw out waste indirectly. These pumps are valued for their precise flow rate, compact design, zero cross-contamination, and high airtightness, ensuring reliable diagnostics.
Corrosion Resistance and Longevity
Miniature pumps must withstand corrosion from cleaning solvents. TOPSFLO pumps offer customizable materials for different solvents and have a long operational lifespan, minimizing replacement needs.
Specifications
  • TF Series: Max flow of 3L/min, water head ≥10m, ambient temperature -20 to 60°C, media temperature -5 to 60°C, lifespan of 15,000 hours.
  • TM Series: Max flow of 17L/min, max pressure 220Kpa, max vacuum 95Kpa, similar temperature ranges and lifespan as TF Series.
Centrifugal Pumps
These pumps are used in IVD for temperature regulation of diagnostic reagent kits and other instruments, ensuring experiment accuracy and reproducibility. They must be reliable, stable, and prevent cross-contamination.
Gear Pumps
Used for cleaning needle inner walls, these pumps require high pressure for effective cleaning. They must provide stable pressure output, resist corrosion, and maintain reliability and durability over extended periods.
Specifications:
  • Max Output Pressure: 10 bar (145.04 psi)
  • Max System Pressure: 20 bar (290.08 psi)
  • Ambient Temperature Range: -30 to 50℃
  • Media Temperature Range: -10 to 100℃
Company Information:
  • Company Name: TOPS INDUSTRY & TECHNOLOGY CO., LTD.
  • Website: www.topsflo.com
  • Email: [email protected]
  • Tagline: The Leader of High-End Micro DC Pump
  • Brand: Excellence in Micro Pump, DC Pump
See more

Catalog excerpts

Medical Equipment Pump Solution-1

MEDICAL EQUIPMENT PUMP TOPSFLO Excellence in Micro Pump,DC Pump

 Open the catalog to page 1
Medical Equipment Pump Solution-2

Industry Overview IVD, which stands for In Vitro Diagnos cs, refers to products that conduct tes ng on samples taken from the human body (such as blood, body fluids, and ssues) outside of the body in order to obtain clinical diagnos c informa on. The IVD industry is subdivided into various sectors including immunodiagnos cs, clinical chemistry, molecular diagnos cs, microbiology diagnos cs, blood diagnos cs, and point-of-care tes ng(POCT). High Precise Micro DC Pump

 Open the catalog to page 2
Medical Equipment Pump Solution-3

EQUIPMENT OVERVIEW TOPSFLO PUMP SOLUTION Micro pumps are a crucial driving component for in vitro diagnos c analysis. They serve as the power elements of fluidic systems and are extensively used in various fields such as clinical chemistry, blood analysis, immunology, microbiology, etc. Micro pumps perform essen al func ons including sample delivery, waste removal, pipeline and component cleaning. Dispense Reagents Sample Dosage Waste liquid disposal Pipeline Cleaning Taking the Fully automated biochemistry analyzer as an example, TOPSFLO micro pump can be used in systems such as needle cleaning,...

 Open the catalog to page 3
Medical Equipment Pump Solution-4

Diaphragm Liquid Pump Diaphragm pumps are the most widely used pumps in IVD instruments, especially in waste systems, where they clean and eliminate waste from reac on cups and pipelines. In this process, diaphragm liquid pumps can directly pump out waste liquids. Alterna vely, miniature vacuum pumps can be used to create a vacuum in sealed containers, indirectly drawing out waste from the instrument. This method is efficient and the waste doesn't pass through the pump chamber, thus extending the pump's lifespan. Depending on the specific applica on, there are larger double-headed and single-headed...

 Open the catalog to page 4
Medical Equipment Pump Solution-5

Corrosion Resistance When flushing pipelines and needles, corrosive solvents are o en used, and it's necessary to promptly remove waste containing crystals or blood clots from the system. Therefore, miniature pumps need to possess a certain level of corrosion resistance. The pump head, diaphragm, and valve components of TOPSFLO diaphragm pumps can all be customized with a variety of materials to accommodate different solvents. Extremely Long Product Lifespan Within the lifecycle of IVD instruments, there is a requirement for miniature pumps to not require replacement, to have a long opera onal...

 Open the catalog to page 5
Medical Equipment Pump Solution-6

Centrifugal Pump TOPSFLO centrifugal pumps are commonly used in IVD to regulate the temperature of in vitro diagnos c reagent kits, enzyme-linked immunosorbent assay (ELISA) instruments, fluorescence analyzers, and more. This ensures the accuracy and reproducibility of experiments. The following are the requirements for pumps in the IVD circula on constant temperature system: Reliability and Stability The IVD equipment demands highly reliable results, requiring centrifugal pumps to exhibit high stability to ensure con nuous opera on without any failures. Furthermore, within the IVD instrument's...

 Open the catalog to page 6
Medical Equipment Pump Solution-7

Gear Pump Gear pumps are commonly used for cleaning the inner walls of needles with high pipe resistance. The cleaning effec veness of the needle is closely related to the internal roughness and design of the inner needle wall, but more importantly, it's correlated with the high pressure provided by the gear pump. High-pressure flushing of the inner walls ensures an adequate cleaning flow even under high resistance condi ons. Stable pressure output Gear pumps should be capable of providing a stable pressure output to ensure the flushing force of liquids within the system. Reliability and Stability...

 Open the catalog to page 7
Medical Equipment Pump Solution-8

TOPSFLO Excellence in Micro Pump,DC Pump THE LEADER OF HIGH-END MICRO DC PUMP TOPS INDUSTRY & TECHNOLOGY CO.,LTD. www.topsflo.com info@topsflo.co

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.