Catalog excerpts

Hollow Fiber Dialyzer
Open the catalog to page 1
membrane offers excellent clinical failure patients. Changes in plasma !k-MG levels Diartysisr-related Amyloidosis and BK Membrane Renal (allure .. .. . (Inoease In the production ot MIIUIOSIC OialVSIS Metabolic disorder gwvwnIMKIIandeiasuss) rnembranes Release of P2-MG +m^M activation ^■Pyrogen Increase in pz-MG pVMG production I , .Increase in the blood by lymphocytes |of interleukin-l amyloid fibrils Dialysis arthrosis Dialysis-related amyloidosis Carpal tunnel syndrome release of IL-1pfrom monocytes contact- ing with each dialysis membrane6' Results of experiment of perfusion and...
Open the catalog to page 2
Changes in plasma (32-MG levels in patients of group A to D7> ilysis-related amyloidosis is a pathological idition induced by deposition in the tissues ^-microglobulin (called P2-MG herein after) emulated in the blood due to renal ited to the production and the deposition of jotoxins and cytokines have been jgested4', too. This figure indicates the Long-term Multicenter Clinical Evaluation Incidence of carpal tunnel syndrome8 Surgical cases + Non-surgical cases Surgical cases carpal tunnel significantly lower PMMA group. Incidence of destructive spondylarthritis and bone cyst8) Surgical...
Open the catalog to page 3
Technical Data; BK-U/P Series Filtryzer Housing Material Filled fluid Sterile water Polymethylmethacrylate (PMMA) Effective surface area (nr) Gamma-ray Irradiation Clearance in vitro (mL/min)* Urea designed Creatinine designed Uric acid designed Phosphate designed UFR in vitro (mUhr, at lOOmmHg)* Sieving coefficient of albumin" "Clearances are date with aqueous solution. "UFR & SC are typical date with bovine blood (Ht 30 +3%, TP 6 ±0.5g/dl) Allowable ranges: Designed clearance: Urea upper limit: +6%, Urea lower limit: see above, Creat: ±6%,
Open the catalog to page 4
EC Representative (Authorized Representitive): Toray International Italy S.r.l. Medical Device Department Via Mecenale 86, 20138 Milan, ITALY International Business Division ARCA Central 21 F„ 2-1, Kinshi 1-chome, Sumida-ku, Tokyo 130-001 3, JAPAN 1-1, Nihonbashi-Muromachi 2-chome, Chuo-ku, Tokyo 103-8666, JAPAN FILTRYZER is the registered trademark ol Toray Industries, Inc
Open the catalog to page 5All Toray catalogs and technical brochures
-
NF-U series
3 Pages
-
Inoue-Balloon Catheter
2 Pages
-
Anthron® P-U catheter
2 Pages
-
TR-FX
2 Pages
-
TQS-88
2 Pages
-
Filtryzer® BK-F
4 Pages
-
Filtryzer® B3
5 Pages
-
Filtryzer® BG
5 Pages
-
Filtryzer® B1
3 Pages