FlowEdge® Monitor & Flowsensors Features - 1

FlowEdge® Bioprocess Bench Flowmeter with Touch Screen Control and Active Display FEATURES: • Quantify Flow in Real Time • Flowmeter measures and displays Volume Flow rate of liquids in ml/min or liter/min • Non-Invasive Clamp-on Flowsensors clip on the outside of flexible tubing and have no direct contact with fluid thus maintaining process sterility • Can measure cell media, WFI, most non-aerated solution even cleaning solutions • Calibrated for WFI with customer specific tubing and temperature conditions • User adjustable calibration program enables onsite calibration with protocol validation • On-board Flow Totalizer can be set to integrate total flow volume delivered TOUCH SCREEN USER INTERFACE PUTS CONTROL AT YOUR FINGERTIPS • Administrator Control with password lock-out feature for selectable settings • Select up to 4 factory calibration conditions (tubing/fluid/temp/custom flow range) • Save up to 6 user defined calibration settings from onsite adjustment program • Set Flow Alarm parameters if required: Low Flow, High Flow, and Bubble/Signal Quality Threshold • Easy 1-2-3 step protocol to select, set and zero Sensor for ongoing measurements • Independent Flow Totalizer Controls (start, stop, reset & alarm) • Totalizer run time accrued and displayed. VISUAL DISPLAY • Easy to read Numeric Average Flow Rate & Totalized Volume • Active Graph of Instantaneous Flow (100 Hz) • Sensor Identification & Settings • Intuitive Tile Navigation ULTRASONIC TRANSIT-TIME TECHNOLOGY • Bidirectional Flow Measurement • Measures Volume Flow, Not Velocity • Sensor geometry & design ensures high resolution measurement & zero offset stability transonic THE MEASURE OF 5* BETTER RESULTS.

Open the catalog to page 1
FlowEdge® Monitor & Flowsensors Features - 2

System Specifications ACCURACY: ± 6% of flow reading over full operational range ± 2-4% of flow reading possible with on-site calibration FLOWMETER MODEL: T701: FlowEdge Bioprocess Bench Flowmeter with Touch Screen Control T702 DIN: FlowEdge DIN Rail Mountable without display; Modbus controlled. B10XL Tubing Flowsensor on silicone tubing FLOWSENSOR MODEL: B n XL-Series Clamp-on Flowsensors 14 Sensor sizes available for 1/8" OD - 1 W" OD tubing 1. In sizes 2-3XL ratio of tubing wall thickness to OD must not exceed 1:5 for PVC; 1:3 for silicone 2. Compatible tubing types include but are not...

Open the catalog to page 2

All Transonic catalogs and technical brochures