Catalog excerpts
table model, stackable Inside dimensions: Temperature range: 5°C (above environ. temp.) to 99,9°C (Ill. similar) Housing Galvanised steel sheet, epoxy-resin-coated, RAL 7035. Interior space Made of high-grade stainless steel. Cleaning friendly by rounded corners, slippery surface in the interior, meets highest hygiene requirements Door Double-walled insulation door, hinged on the right-hand side. (Left hinged version possible with surcharge) Magnetic, all-round sealing strip, resistant to laboratory cleaning agents. Optional: Additionally equipped with an inner glass door. FAN Fan speed adjustable in 10 steps. When heating up, settings lower than 6 will be ignored. The fan stops about 30 seconds after opening the door. The speed of the fan will reduce, or even stopped if operating at a temperature close to the ambient temperature. Interior fittings Standard: 2 pcs. Chrome-nickel steel wire shelves (max. 16 pcs.) Max. load per shelf: 20 kg in case of constant distribution – total load: 70 kg Shelf dimension: W = 534 mm, D = 325 mm Optional: perforated stainless steel shelves stainless steel shelves Control and instrument panel In the door arranged with all control units, temperature controller with digital display tritec ® Gesellschaft für Labortechnik und Umweltsimulation mbH Hüttenstraße 9 D-30165 Hannover Homepage www.tritec-klima.com E-mail info@tritec-klima.de Phone ++49-511/3523508 Fax ++49-511/3521715 technische Änderungen vorbehalten
Open the catalog to page 1table model, stackable Temperature working range: Temperature accuracy: 5°C above ambient temperature up to 99,9°C time: +/-0,2°C, spatial: +/- 1,0°C Microprocessor controller with OLED display The temperature and time are entered via a touch button below the display. The keyboard is password-protected to prevent access by unauthorised persons. Alarms The following abnormal operating conditions are indicated optically and acoustically in the temperature controller: • Over-temperature alarm • Low temperature alarm • Sensor error • Real-time clock setting • Data error • power failure Alarm...
Open the catalog to page 2table model, stackable Timer There are two different programs available for timings. 1. Standard timer Adjustable up to 99 hours and 59 min. The timer starts when the setpoint temperature is reached. In case of power failure of more than 5 min. the time period begins again. 2. Real-time program Provides the ability to work with two different temperatures. Start and end time selectable between weeks/ days for the temperature. The real-time clock for approximately 10 minutes after a power failure, battery-supported. Necessary battery replacement is indicated safety thermostat Automatic safety...
Open the catalog to page 3table model, stackable Special Equipment and Accessories: Electronic CO2 control unit (infrared measurement). Operating range from 1 - 10% (20%), control accuracy +/- 0.5%. Temperature: 5°C above ambient temperature up to 55°C. Actual value permanently displayed digitally, setpoint adjustable via push-button and digitally readable Cable port with cover Approx. 30 mm or 50 mm ∅. For example, to create access for operator measurement lines, etc. Main socket / damp room design Installed inside the cabinet, 230 V, 50 Hz tritec ® Gesellschaft für Labortechnik und Umweltsimulation mbH...
Open the catalog to page 4table model, stackable Qualifications DQ (Design Qualification) Definition: Documented proof that the quality-related, GMP-related requirements has been adequately addressed in the design of equipment, including buildings, premises and auxiliary equipment The user-requirement profiles (specifications) are documented and confirmed by us. On request, a specification can be created by us. IQ (Installation Qualification) Definition: Documented proof that critical equipment and systems have been delivered and installed in accordance with the set requirements and government regulations. The IQ...
Open the catalog to page 5All Tritec catalogs and technical brochures
-
TC 2000
2 Pages
-
TS 9430
4 Pages
-
TS 9135
4 Pages
-
TS 9053
4 Pages
-
TS 9026
4 Pages
-
B 9420
5 Pages
-
B 9051
5 Pages
-
B 9025
5 Pages
-
KB 7070 LL
3 Pages
-
KB 7140 LL
3 Pages
-
KB 9207
4 Pages
-
KB 9206
5 Pages
-
KB 9205
4 Pages
-
KB 9204
4 Pages
-
KB 9201
4 Pages
-
KB 9400
4 Pages
-
KB 9182
4 Pages
-
KB 7140 F-LL
4 Pages
-
KB 7070 F-LL
3 Pages
-
KB 9400 F-LL
4 Pages
-
KB 9400 F
4 Pages
-
TC 404
2 Pages
-
TC 403
2 Pages
-
TC 401
2 Pages
-
TC 402
2 Pages
-
TC 409
2 Pages
-
TC 408
2 Pages
-
TC 407
2 Pages
-
TC 406
2 Pages
-
TC 405
2 Pages
-
TC 704
4 Pages
-
TC 703
4 Pages
-
TC 702
4 Pages
-
TC 701
4 Pages
-
TC 802-ex
4 Pages
-
TC 802
3 Pages
-
TC 220-2
6 Pages
-
TC 219-2
6 Pages
-
TC 218-2
6 Pages
-
TC 217-2
6 Pages
-
TC 905
3 Pages
-
TC 904
3 Pages
-
TC 903
3 Pages
-
TC 902
3 Pages
-
TC 901
3 Pages
-
TC 1019-ex
5 Pages
-
TC 1018-ex
5 Pages
-
TC 1005-ex
3 Pages
-
TC 1017-ex
5 Pages
-
TC 1006-ex
3 Pages
-
TC 312
4 Pages
-
TC 311
4 Pages
-
TC 310
4 Pages
-
TC 1011-ex
5 Pages
-
TC 1016-ex
5 Pages
-
TC 1007-ex
3 Pages
-
TC 1015-ex
5 Pages
-
TC 513
5 Pages
-
TC 512
5 Pages
-
TC 517
5 Pages
-
TC 516
5 Pages
-
TC 515
5 Pages
-
TC 514
5 Pages
-
TC 521-S
5 Pages
-
TC 520-S
5 Pages
-
TC 305
4 Pages
-
TC 304-Basic
5 Pages
-
TC 304-Premium
5 Pages
-
TC 303-Premium
5 Pages
-
TC 303-Basic
5 Pages
-
TC 302-Premium
5 Pages
-
TC 302-Basic
5 Pages
-
TC 301
4 Pages
-
TC 300
4 Pages
-
TC 214
5 Pages
-
TC 213
5 Pages
-
TC 212
5 Pages
-
TC 1019-S
5 Pages
-
TC 211
5 Pages
-
TC 210
5 Pages
-
TC 1018-S
5 Pages
-
TC 209
5 Pages
-
TC 1017
5 Pages
-
TC 230
5 Pages
-
TC 1016-S
5 Pages
-
TC 231
6 Pages
-
TC 1015-S
5 Pages
-
TC 1001-ex
3 Pages
-
TC 1207
5 Pages
-
TC 1000-TH
5 Pages
-
TC 1000-AX
5 Pages
-
TC 1206
5 Pages
-
TC 1205
5 Pages
-
TC 1204
5 Pages
-
TC 1203
5 Pages
-
TC 1202
5 Pages
-
TC 605
6 Pages
-
TC 604
6 Pages
-
TC 603
6 Pages
-
TC 602
6 Pages
-
TC 601
6 Pages
-
TC 506
5 Pages
-
TC 511
5 Pages
-
TC 505
5 Pages
-
TC 510
5 Pages
-
TC 504
5 Pages
-
TC 560-G
5 Pages
-
TC 560
5 Pages
-
TC 550-G
5 Pages
-
TC 550
5 Pages
-
TC 509
5 Pages
-
TC 503
5 Pages
-
TC 508
5 Pages
-
TC 502
5 Pages
-
TC 507
6 Pages
-
TC 501
5 Pages
-
TC 500-V
5 Pages
-
TC 500-H
5 Pages
-
TC 1014-ex
5 Pages
-
TC 208
5 Pages
-
TC 1013-ex
5 Pages
-
TC 207
5 Pages
-
TC 1012-ex
5 Pages
-
TC 206
5 Pages
-
TC 205
5 Pages
-
TC 204
5 Pages
-
TC 1010-ex
5 Pages
-
TC 1004-ex
3 Pages
-
TC 203
5 Pages
-
TC 1009-ex
5 Pages
-
TC 202
5 Pages
-
TC 201
5 Pages
-
TC 200
6 Pages
-
TC 114-2
6 Pages
-
TC 107
5 Pages
-
TC 113-2
6 Pages
-
TC 106
5 Pages
-
TC 120
6 Pages
-
TC 112-2
6 Pages
-
TC 105
5 Pages
-
TC 111-2
6 Pages
-
TC 104
5 Pages
-
TC 109-2
6 Pages
-
TC 103
5 Pages
-
TC 102
5 Pages
-
TC 108-2
6 Pages
-
TC 101
6 Pages
-
TC 100-V
6 Pages
-
TC 100-H
6 Pages