Catalog excerpts
Laboratory Pass-Through Refrigerator, two-door With air circulation. Also in accordance with DIN 13277 External Dimensions: Internal Dimensions: W = 1350 mm (clear door with: 540 mm) D = 570 mm H = 1335 mm (lower edge of evaporator) Temperature range: Optional: Housing galvanized sheet steel with high quality white coating, antibacterial coated. With 4 feet, height adjustable. Optional: of stainless steel (Backplane, as well as top and bottom side of the cabinet of galvanised sheet steel) Set of 4 castors, 2 lockable Interior space Inner case of galvanized sheet steel with high quality white coating, antibacterial coated. Cleaning friendly by rounded corners, slippery surface in the interior, meets highest hygiene requirements Optional: of stainless steel Insulation high density foamed-in-place polyurethane, with a thickness of 75 mm. CFC-free Circulaton air cooling for rapid and uniform temperature control, reducing temperature gradients to a minimum. When the door is "open" the circulating fan is switched off automatically by a micro switch in order to prevent warmer ambient air being drawn in. Doors Front and rear equipped with one solid material door each. Optional: - glass door - Electric locking If the door on one side is opened, the door on the other side locks automatically. - Traffic light signal (red/green) When a door is opened, a red lamp lights up on the other side. When the door is closed, a green lamp lights up. This prevents both sides from being open at the same time. are open at the same time. - Door lock with 2 keys, or electronic door lock Interior fittings 8 pcs. Grating-type shelves (dim.: 530 x 550 mm), white coated (max. 26 shelves possible) Optional: - Stainless Steel shelves - Grating-type baskets - Interior lighting with automatic ON/OFF micro switch tritec ® Gesellschaft für Labortechnik und Umweltsimulation mbH Hüttenstraße 9 D-30165 Hannover Homepage www.tritec-klima.com E-mail info@tritec-klima.de Phone ++49-511/3523508 Fax ++49-511/3521715 technische Änderungen vorbehalten
Open the catalog to page 1Laboratory Pass-Through Refrigerator, two-door With air circulation. Also in accordance with DIN 13277 Control system located above the door Touchscreen temperature controller, TC 2015 Working range from 2°C to 20°C Optional: from -5°C to 20°C (provided that the ambient temperature is around 4°C above the set point) Temperature accuracy +/- 1,8°C after stabilising (with 50% filling) Language in German / English adjustable Touchscreen Display, size 12,5 cm (5“) PT1000 temperature sensor for better temperature control accuracy Digital temperature setting and display with an accuracy of 0.1 °...
Open the catalog to page 2Laboratory Pass-Through Refrigerator, two-door With air circulation. Also in accordance with DIN 13277 • Network Connection 2 Ethernet ports 10/100 Mbps available. This interface can be accessed directly on the log data of the controller to import in the software. NO/NC contact Alarm signal time delayed (adjustable) Language: English / German, other languages on request Maintenance message: Notification that maintenance should be carried out. Test facilities for Alarm limits and battery charge status In the housing of the temperature regulator there are all relevant components for using the...
Open the catalog to page 3Laboratory Pass-Through Refrigerator, two-door With air circulation. Also in accordance with DIN 13277 Special Equipment and Accessories: GSM Modul Connecting to the potential-free output. In case of an alarm either a message or a call will be sent automatically. Archiving of 1000 phone numbers is possible. The GSM module is equipped with a rechargeable battery. Automatic alert via SMS when the credit has been used on the SIM card. 6 units can be connected per module. The SIM card is not included Round Chart recorder to record temperature, permanently installed in control panel. Comes as...
Open the catalog to page 4Laboratory Pass-Through Refrigerator, two-door With air circulation. Also in accordance with DIN 13277 Qualifications DQ (Design Qualification) Definition: Documented proof that the quality-related, GMP-related requirements has been adequately addressed in the design of equipment, including buildings, premises and auxiliary equipment The user-requirement profiles (specifications) are documented and confirmed by us. On request, a specification can be created by us. IQ (Installation Qualification) Definition: Documented proof that critical equipment and systems have been delivered and...
Open the catalog to page 5All Tritec catalogs and technical brochures
-
TC 2000
2 Pages
-
TS 9430
4 Pages
-
TS 9135
4 Pages
-
TS 9053
4 Pages
-
TS 9026
4 Pages
-
B 9420
5 Pages
-
B 9130
5 Pages
-
B 9051
5 Pages
-
B 9025
5 Pages
-
KB 7070 LL
3 Pages
-
KB 7140 LL
3 Pages
-
KB 9207
4 Pages
-
KB 9206
5 Pages
-
KB 9205
4 Pages
-
KB 9204
4 Pages
-
KB 9201
4 Pages
-
KB 9400
4 Pages
-
KB 9182
4 Pages
-
KB 7140 F-LL
4 Pages
-
KB 7070 F-LL
3 Pages
-
KB 9400 F-LL
4 Pages
-
KB 9400 F
4 Pages
-
TC 404
2 Pages
-
TC 403
2 Pages
-
TC 401
2 Pages
-
TC 402
2 Pages
-
TC 409
2 Pages
-
TC 408
2 Pages
-
TC 407
2 Pages
-
TC 406
2 Pages
-
TC 405
2 Pages
-
TC 704
4 Pages
-
TC 703
4 Pages
-
TC 702
4 Pages
-
TC 701
4 Pages
-
TC 802-ex
4 Pages
-
TC 802
3 Pages
-
TC 220-2
6 Pages
-
TC 219-2
6 Pages
-
TC 218-2
6 Pages
-
TC 217-2
6 Pages
-
TC 905
3 Pages
-
TC 904
3 Pages
-
TC 903
3 Pages
-
TC 902
3 Pages
-
TC 901
3 Pages
-
TC 1019-ex
5 Pages
-
TC 1018-ex
5 Pages
-
TC 1005-ex
3 Pages
-
TC 1017-ex
5 Pages
-
TC 1006-ex
3 Pages
-
TC 312
4 Pages
-
TC 311
4 Pages
-
TC 310
4 Pages
-
TC 1011-ex
5 Pages
-
TC 1016-ex
5 Pages
-
TC 1007-ex
3 Pages
-
TC 1015-ex
5 Pages
-
TC 513
5 Pages
-
TC 512
5 Pages
-
TC 517
5 Pages
-
TC 516
5 Pages
-
TC 515
5 Pages
-
TC 514
5 Pages
-
TC 521-S
5 Pages
-
TC 520-S
5 Pages
-
TC 305
4 Pages
-
TC 304-Basic
5 Pages
-
TC 304-Premium
5 Pages
-
TC 303-Premium
5 Pages
-
TC 303-Basic
5 Pages
-
TC 302-Premium
5 Pages
-
TC 302-Basic
5 Pages
-
TC 301
4 Pages
-
TC 300
4 Pages
-
TC 214
5 Pages
-
TC 213
5 Pages
-
TC 212
5 Pages
-
TC 1019-S
5 Pages
-
TC 211
5 Pages
-
TC 210
5 Pages
-
TC 1018-S
5 Pages
-
TC 209
5 Pages
-
TC 1017
5 Pages
-
TC 230
5 Pages
-
TC 1016-S
5 Pages
-
TC 231
6 Pages
-
TC 1015-S
5 Pages
-
TC 1001-ex
3 Pages
-
TC 1207
5 Pages
-
TC 1000-TH
5 Pages
-
TC 1000-AX
5 Pages
-
TC 1205
5 Pages
-
TC 1204
5 Pages
-
TC 1203
5 Pages
-
TC 1202
5 Pages
-
TC 605
6 Pages
-
TC 604
6 Pages
-
TC 603
6 Pages
-
TC 602
6 Pages
-
TC 601
6 Pages
-
TC 506
5 Pages
-
TC 511
5 Pages
-
TC 505
5 Pages
-
TC 510
5 Pages
-
TC 504
5 Pages
-
TC 560-G
5 Pages
-
TC 560
5 Pages
-
TC 550-G
5 Pages
-
TC 550
5 Pages
-
TC 509
5 Pages
-
TC 503
5 Pages
-
TC 508
5 Pages
-
TC 502
5 Pages
-
TC 507
6 Pages
-
TC 501
5 Pages
-
TC 500-V
5 Pages
-
TC 500-H
5 Pages
-
TC 1014-ex
5 Pages
-
TC 208
5 Pages
-
TC 1013-ex
5 Pages
-
TC 207
5 Pages
-
TC 1012-ex
5 Pages
-
TC 206
5 Pages
-
TC 205
5 Pages
-
TC 204
5 Pages
-
TC 1010-ex
5 Pages
-
TC 1004-ex
3 Pages
-
TC 203
5 Pages
-
TC 1009-ex
5 Pages
-
TC 202
5 Pages
-
TC 201
5 Pages
-
TC 200
6 Pages
-
TC 114-2
6 Pages
-
TC 107
5 Pages
-
TC 113-2
6 Pages
-
TC 106
5 Pages
-
TC 120
6 Pages
-
TC 112-2
6 Pages
-
TC 105
5 Pages
-
TC 111-2
6 Pages
-
TC 104
5 Pages
-
TC 109-2
6 Pages
-
TC 103
5 Pages
-
TC 102
5 Pages
-
TC 108-2
6 Pages
-
TC 101
6 Pages
-
TC 100-V
6 Pages
-
TC 100-H
6 Pages