Catalog excerpts
Laboratory Air circulated Refrigerator (undercounter), also in accordance to DIN 13277 External Dimension: Internal Dimension: Housing (high size) galvanized sheet steel with high quality white coating, antibacterial coated. 4 feet, height adjustable. Optional: with 4 castors of stainless steel (Backplane, as well as top and bottom side of the cabinet of galvanised sheet steel) Interior space Inner case of galvanized sheet steel with high quality white coating, antibacterial coated. Cleaning friendly by rounded corners, slippery surface in the interior, meets highest hygiene requirements Optional: of stainless steel Integration and foundation possible. A sufficient ventilation has to be respected! Attention: If the optional tritec TC 2015 temperature controller is installed, the total height of the unit changes to 940 mm. Insulation high density foamed-in-place polyurethane, with a thickness of 40 mm. CFC-free Circulation air cooling for rapid and uniform temperature control, reducing temperature gradients to a minimum. When the door is "open" the circulating fan is switched off automatically by a micro switch in order to prevent warmer ambient air being drawn in. Door Solid door, supplied as standard with right hand hinge, also available with left hand hinge at no extra cost.. Grease resistant magnetic seal. Optional: with door lock with three-layer thermally insulating glass door Interior fittings 2 pcs. Grating-type shelves, white coated (dim: 400x500 mm) max. 5 shelves possible Optional: Stainless-steel drawer compartments with 2 lengthwise dividers (max. 5 drawers possible) with telescopic-type guides on rollers with stops, (lengthwise dividers easily removable) Drawer dimensions: 380x450x77 mm (WxDxH) Usable width between the lengthwise dividers: 110 mm LED-Interior lighting with automatic ON/OFF micro switch tritec ® Gesellschaft für Labortechnik und Umweltsimulation mbH Hüttenstraße 9 D-30165 Hannover Homepage www.tritec-klima.com E-mail info@tritec-klima.de Phone ++49-511/3523508 Fax ++49-511/3521715 technische Änderungen vorbehalten
Open the catalog to page 1Laboratory Air circulated Refrigerator (undercounter), also in accordance to DIN 13277 Control system located beneath the door High quality electronic temperature controller Actual value permanently displayed. Set value adjustable digitally by switches. Temperature range from 2°C to 20°C (assuming the ambient temperature is approximately 4 ° C above the setpoint). Temperature accuracy +/- 1,8°C after stabilisation (with 50% of loading) Acoustic signal when the set value is undercut or exceeded Potential-free connection socket for extern alarm indication Optional: Temperature regulator TC...
Open the catalog to page 2Laboratory Air circulated Refrigerator (undercounter), also in accordance to DIN 13277 Special Equipment and Accessories : Touchscreen temperature controller, TC 2015 Working range from 2°C to 20°C (provided that the ambient temperature is around 4°C above the set point) Temperature accuracy +/- 1,8°C after stabilising (with 50% filling) Language in German / English adjustable Touchscreen Display, size 12,5 cm (5“) PT1000 temperature sensor for better temperature control accuracy Digital temperature setting and display with an accuracy of 0.1 ° C Power supply of 100-240V, 50-60Hz Password...
Open the catalog to page 3Laboratory Air circulated Refrigerator (undercounter), also in accordance to DIN 13277 • Network Connection 2 Ethernet ports 10/100 Mbps available. This interface can be accessed directly on the log data of the controller to import in the software. NO/NC contact Alarm signal time delayed (adjustable) Language: English / German, other languages on request Maintenance message: Notification that maintenance should be carried out. Test facilities for Alarm limits and battery charge status In the housing of the temperature regulator there are all relevant components for using the cabinet....
Open the catalog to page 4Laboratory Air circulated Refrigerator (undercounter), also in accordance to DIN 13277 GSM Modul Connecting to the potential-free output. In case of an alarm either a message or a call will be sent automatically. Archiving of 1000 phone numbers is possible. The GSM module is equipped with a rechargeable battery. Automatic alert via SMS when the credit has been used on the SIM card. 6 units can be connected per module. The SIM card is not included Round Chart recorder to record temperature, permanently installed in control panel. Comes as standard with battery back-up power supply for...
Open the catalog to page 5Laboratory Air circulated Refrigerator (undercounter), also in accordance to DIN 13277 Qualifications DQ (Design Qualification) Definition: Documented proof that the quality-related, GMP-related requirements has been adequately addressed in the design of equipment, including buildings, premises and auxiliary equipment The user-requirement profiles (specifications) are documented and confirmed by us. On request, a specification can be created by us. IQ (Installation Qualification) Definition: Documented proof that critical equipment and systems have been delivered and installed in accordance...
Open the catalog to page 6All Tritec catalogs and technical brochures
-
TC 2000
2 Pages
-
TS 9430
4 Pages
-
TS 9135
4 Pages
-
TS 9053
4 Pages
-
TS 9026
4 Pages
-
B 9420
5 Pages
-
B 9130
5 Pages
-
B 9051
5 Pages
-
B 9025
5 Pages
-
KB 7070 LL
3 Pages
-
KB 7140 LL
3 Pages
-
KB 9207
4 Pages
-
KB 9206
5 Pages
-
KB 9205
4 Pages
-
KB 9204
4 Pages
-
KB 9201
4 Pages
-
KB 9400
4 Pages
-
KB 9182
4 Pages
-
KB 7140 F-LL
4 Pages
-
KB 7070 F-LL
3 Pages
-
KB 9400 F-LL
4 Pages
-
KB 9400 F
4 Pages
-
TC 404
2 Pages
-
TC 403
2 Pages
-
TC 401
2 Pages
-
TC 402
2 Pages
-
TC 409
2 Pages
-
TC 408
2 Pages
-
TC 407
2 Pages
-
TC 406
2 Pages
-
TC 405
2 Pages
-
TC 704
4 Pages
-
TC 703
4 Pages
-
TC 702
4 Pages
-
TC 701
4 Pages
-
TC 802-ex
4 Pages
-
TC 802
3 Pages
-
TC 220-2
6 Pages
-
TC 219-2
6 Pages
-
TC 218-2
6 Pages
-
TC 217-2
6 Pages
-
TC 905
3 Pages
-
TC 904
3 Pages
-
TC 903
3 Pages
-
TC 902
3 Pages
-
TC 901
3 Pages
-
TC 1019-ex
5 Pages
-
TC 1018-ex
5 Pages
-
TC 1005-ex
3 Pages
-
TC 1017-ex
5 Pages
-
TC 1006-ex
3 Pages
-
TC 312
4 Pages
-
TC 311
4 Pages
-
TC 310
4 Pages
-
TC 1011-ex
5 Pages
-
TC 1016-ex
5 Pages
-
TC 1007-ex
3 Pages
-
TC 1015-ex
5 Pages
-
TC 513
5 Pages
-
TC 512
5 Pages
-
TC 517
5 Pages
-
TC 516
5 Pages
-
TC 515
5 Pages
-
TC 514
5 Pages
-
TC 521-S
5 Pages
-
TC 520-S
5 Pages
-
TC 305
4 Pages
-
TC 304-Basic
5 Pages
-
TC 304-Premium
5 Pages
-
TC 303-Premium
5 Pages
-
TC 303-Basic
5 Pages
-
TC 302-Premium
5 Pages
-
TC 302-Basic
5 Pages
-
TC 301
4 Pages
-
TC 300
4 Pages
-
TC 214
5 Pages
-
TC 213
5 Pages
-
TC 212
5 Pages
-
TC 1019-S
5 Pages
-
TC 211
5 Pages
-
TC 210
5 Pages
-
TC 1018-S
5 Pages
-
TC 209
5 Pages
-
TC 1017
5 Pages
-
TC 230
5 Pages
-
TC 1016-S
5 Pages
-
TC 231
6 Pages
-
TC 1015-S
5 Pages
-
TC 1001-ex
3 Pages
-
TC 1207
5 Pages
-
TC 1000-TH
5 Pages
-
TC 1000-AX
5 Pages
-
TC 1206
5 Pages
-
TC 1205
5 Pages
-
TC 1204
5 Pages
-
TC 1203
5 Pages
-
TC 1202
5 Pages
-
TC 605
6 Pages
-
TC 604
6 Pages
-
TC 603
6 Pages
-
TC 602
6 Pages
-
TC 601
6 Pages
-
TC 506
5 Pages
-
TC 511
5 Pages
-
TC 505
5 Pages
-
TC 510
5 Pages
-
TC 504
5 Pages
-
TC 560-G
5 Pages
-
TC 560
5 Pages
-
TC 550-G
5 Pages
-
TC 550
5 Pages
-
TC 509
5 Pages
-
TC 503
5 Pages
-
TC 508
5 Pages
-
TC 502
5 Pages
-
TC 507
6 Pages
-
TC 501
5 Pages
-
TC 500-V
5 Pages
-
TC 500-H
5 Pages
-
TC 1014-ex
5 Pages
-
TC 208
5 Pages
-
TC 1013-ex
5 Pages
-
TC 207
5 Pages
-
TC 1012-ex
5 Pages
-
TC 206
5 Pages
-
TC 205
5 Pages
-
TC 204
5 Pages
-
TC 1010-ex
5 Pages
-
TC 1004-ex
3 Pages
-
TC 203
5 Pages
-
TC 1009-ex
5 Pages
-
TC 202
5 Pages
-
TC 201
5 Pages
-
TC 114-2
6 Pages
-
TC 107
5 Pages
-
TC 113-2
6 Pages
-
TC 106
5 Pages
-
TC 120
6 Pages
-
TC 112-2
6 Pages
-
TC 105
5 Pages
-
TC 111-2
6 Pages
-
TC 104
5 Pages
-
TC 109-2
6 Pages
-
TC 103
5 Pages
-
TC 102
5 Pages
-
TC 108-2
6 Pages
-
TC 101
6 Pages
-
TC 100-V
6 Pages
-
TC 100-H
6 Pages