Catalog excerpts
Laboratory Refrigerator/Deep Freezer External Dimension: Inside Dimension: Temperature range: Useful space at the bottom B = 431 mm D = 435 mm H = 597 mm Housing galvanized sheet steel with white coating. 2 isolated doors supplied as standard with right hand hinge (reversible), Including 2 pcs. door locks. Grease resistant magnetic seal. Interior space of high-quality plastic. Cleaning friendly by rounded corners, slippery surface in the interior, meets highest hygiene requirements Isolation Polyurethane, free of CFCS, 70 mm Circulating air cooling in the refrigeration unit for rapid and uniform temperature control, reducing temperature gradients to a minimum. When the door is "open" the circulating fan is switched off automatically by a micro switch in order to prevent warmer ambient air being drawn in. Interior fittings Top: 4 shelves, plastic-coated, height-adjustable, dim. 440 x 409 mm (max. load 40 kg each) Bottom: 3 glass shelves with drawers, white plastic, closed transparent front (max. load 20 kg) 2 pcs. (425x395x180 mm) 1 pcs. (425x225x190 mm) 1 cable port each for operator's own measuring lines, diameter approx. 10 mm tritec ® Gesellschaft für Labortechnik und Umweltsimulation mbH Hüttenstraße 9 D-30165 Hannover Homepage www.tritec-klima.com E-mail info@tritec-klima.de Phone ++49-511/3523508 Fax ++49-511/3521715 technische Änderungen vorbehalten
Open the catalog to page 1Laboratory Refrigerator/Deep Freezer Control system located above door. 2 pcs. High quality electronic temperature controller. Actual and set value display digital. Actual value permanently readable Set value digital adjustable by switch Working range from 3°C to 16° (+/- 2°C) and -9°C to -30°C (+/-3,5°C) - Temperature differences are displayed visually and acoustically, Door open Alarm Potential free alarm output for remote transmission Power failure alarm when mains power returns (optical) RS 485 interface Min/max temperature Temperature sensor alarm Product protection against low...
Open the catalog to page 2Laboratory Refrigerator/Deep Freezer Qualifications DQ (Design Qualification) Definition: Documented proof that the quality-related, GMP-related requirements has been adequately addressed in the design of equipment, including buildings, premises and auxiliary equipment The user-requirement profiles (specifications) are documented and confirmed by us. On request, a specification can be created by us. IQ (Installation Qualification) Definition: Documented proof that critical equipment and systems have been delivered and installed in accordance with the set requirements and government...
Open the catalog to page 3All Tritec catalogs and technical brochures
-
TC 2000
2 Pages
-
TS 9430
4 Pages
-
TS 9135
4 Pages
-
TS 9053
4 Pages
-
TS 9026
4 Pages
-
B 9420
5 Pages
-
B 9130
5 Pages
-
B 9051
5 Pages
-
B 9025
5 Pages
-
KB 7070 LL
3 Pages
-
KB 7140 LL
3 Pages
-
KB 9207
4 Pages
-
KB 9206
5 Pages
-
KB 9205
4 Pages
-
KB 9204
4 Pages
-
KB 9201
4 Pages
-
KB 9400
4 Pages
-
KB 9182
4 Pages
-
KB 7140 F-LL
4 Pages
-
KB 7070 F-LL
3 Pages
-
KB 9400 F-LL
4 Pages
-
KB 9400 F
4 Pages
-
TC 404
2 Pages
-
TC 403
2 Pages
-
TC 401
2 Pages
-
TC 402
2 Pages
-
TC 409
2 Pages
-
TC 408
2 Pages
-
TC 407
2 Pages
-
TC 406
2 Pages
-
TC 405
2 Pages
-
TC 704
4 Pages
-
TC 703
4 Pages
-
TC 702
4 Pages
-
TC 701
4 Pages
-
TC 802-ex
4 Pages
-
TC 220-2
6 Pages
-
TC 219-2
6 Pages
-
TC 218-2
6 Pages
-
TC 217-2
6 Pages
-
TC 905
3 Pages
-
TC 904
3 Pages
-
TC 903
3 Pages
-
TC 902
3 Pages
-
TC 901
3 Pages
-
TC 1019-ex
5 Pages
-
TC 1018-ex
5 Pages
-
TC 1005-ex
3 Pages
-
TC 1017-ex
5 Pages
-
TC 1006-ex
3 Pages
-
TC 312
4 Pages
-
TC 311
4 Pages
-
TC 310
4 Pages
-
TC 1011-ex
5 Pages
-
TC 1016-ex
5 Pages
-
TC 1007-ex
3 Pages
-
TC 1015-ex
5 Pages
-
TC 513
5 Pages
-
TC 512
5 Pages
-
TC 517
5 Pages
-
TC 516
5 Pages
-
TC 515
5 Pages
-
TC 514
5 Pages
-
TC 521-S
5 Pages
-
TC 520-S
5 Pages
-
TC 305
4 Pages
-
TC 304-Basic
5 Pages
-
TC 304-Premium
5 Pages
-
TC 303-Premium
5 Pages
-
TC 303-Basic
5 Pages
-
TC 302-Premium
5 Pages
-
TC 302-Basic
5 Pages
-
TC 301
4 Pages
-
TC 300
4 Pages
-
TC 214
5 Pages
-
TC 213
5 Pages
-
TC 212
5 Pages
-
TC 1019-S
5 Pages
-
TC 211
5 Pages
-
TC 210
5 Pages
-
TC 1018-S
5 Pages
-
TC 209
5 Pages
-
TC 1017
5 Pages
-
TC 230
5 Pages
-
TC 1016-S
5 Pages
-
TC 231
6 Pages
-
TC 1015-S
5 Pages
-
TC 1001-ex
3 Pages
-
TC 1207
5 Pages
-
TC 1000-TH
5 Pages
-
TC 1000-AX
5 Pages
-
TC 1206
5 Pages
-
TC 1205
5 Pages
-
TC 1204
5 Pages
-
TC 1203
5 Pages
-
TC 1202
5 Pages
-
TC 605
6 Pages
-
TC 604
6 Pages
-
TC 603
6 Pages
-
TC 602
6 Pages
-
TC 601
6 Pages
-
TC 506
5 Pages
-
TC 511
5 Pages
-
TC 505
5 Pages
-
TC 510
5 Pages
-
TC 504
5 Pages
-
TC 560-G
5 Pages
-
TC 560
5 Pages
-
TC 550-G
5 Pages
-
TC 550
5 Pages
-
TC 509
5 Pages
-
TC 503
5 Pages
-
TC 508
5 Pages
-
TC 502
5 Pages
-
TC 507
6 Pages
-
TC 501
5 Pages
-
TC 500-V
5 Pages
-
TC 500-H
5 Pages
-
TC 1014-ex
5 Pages
-
TC 208
5 Pages
-
TC 1013-ex
5 Pages
-
TC 207
5 Pages
-
TC 1012-ex
5 Pages
-
TC 206
5 Pages
-
TC 205
5 Pages
-
TC 204
5 Pages
-
TC 1010-ex
5 Pages
-
TC 1004-ex
3 Pages
-
TC 203
5 Pages
-
TC 1009-ex
5 Pages
-
TC 202
5 Pages
-
TC 201
5 Pages
-
TC 200
6 Pages
-
TC 114-2
6 Pages
-
TC 107
5 Pages
-
TC 113-2
6 Pages
-
TC 106
5 Pages
-
TC 120
6 Pages
-
TC 112-2
6 Pages
-
TC 105
5 Pages
-
TC 111-2
6 Pages
-
TC 104
5 Pages
-
TC 109-2
6 Pages
-
TC 103
5 Pages
-
TC 102
5 Pages
-
TC 108-2
6 Pages
-
TC 101
6 Pages
-
TC 100-V
6 Pages
-
TC 100-H
6 Pages