User Manual CN-A01

User Manual CN-A01
1 / 10 PagesView full catalog

User Manual CN-A01

Product catalog summary
Description
This user manual details the Canine Phantom for X-Ray CT, US, and MRI, designed for veterinary education and clinical training. The model is based on a CT dataset of a 2-year-old Bull Mastiff x Rhodesian Ridgeback, scaled down for ease of handling. It features advanced AI software for precise anatomical structure extraction, offering high anatomical fidelity for diagnostic and procedural training. Key improvements include enhanced ultrasoft tissue and palpable internal organs.

Anatomy
The phantom includes 3D-printed skeletal structures such as the skull, jawbone, spine, ribcage, and pelvis. It also features realistic internal organs like the heart, lungs, liver, kidneys, and more, all designed to mimic real canine anatomy.

Technical Properties
The phantom's tissues have specific sound velocity, density, hardness, and attenuation properties. Thermal properties of bone-mimicking tissue include thermal conductivity and specific heat. HU values for tissue-mimicking materials are provided for various organs.

Design
The design section is not detailed in the document.

Scanning Instructions
The phantom can be scanned using standard protocols for real dogs, in both horizontal and vertical positions. Ultrasound gel is recommended for clearer images, and instructions for cleaning the gel are provided.

Materials Used
Soft tissues and organs are made from urethane-based soft resin, while synthetic bones use a ceramic-reinforced epoxy-based composite.

Size and Weight
The phantom measures 110cm x 20cm x 20cm and weighs approximately 16kg. Shipment dimensions and weight are also provided.

Included In Order
The package includes the Canine Phantom, a user manual, a hard carry case, and a 2-year warranty with unlimited customer service.

Handling the Phantom
Guidelines for safe handling include using two individuals for movement and holding the phantom by its torso. A stretcher is recommended for transport.

Storage
The phantom should be protected from intense UV light and stored in a dry, dark place when not in use.

Cleaning
The phantom is water-resistant and can be cleaned with water or soapy water. It is resistant to chemicals, but testing on a small area is advised before using strong solvents.

FAQs
For additional FAQs, refer to the provided link.
See more

Catalog excerpts

User Manual CN-A01-1

TRUE PHANTOM SOLUTIONS User ManualCanine Phantom for X-Ray CT, US, MRI [CN-A01] VERSION 2.3 ■ 07 August 2026 [email protected] ■ www.truephantom.com

 Open the catalog to page 1
User Manual CN-A01-2

TRUE PHANTOM SOLUTIONS INC.

 Open the catalog to page 2
User Manual CN-A01-3

TRUE PHANTOM SOLUTIONS INC. 1. Description This next-generation Canine Phantom has been meticulously engineered to support the evolving needs of veterinary education, research, and hands-on clinical training. Building upon the success of our previous Dog Phantom, this upgraded model incorporates valuable feedback from veterinary institutions and universities around the world, including partners in Canada, the USA, the UK, and Australia. This advanced training model features a skeletal and soft tissue structure derived from a real CT dataset of a 2year-old Bull Mastiff x Rhodesian Ridgeback weighing...

 Open the catalog to page 3
User Manual CN-A01-4

TRUE PHANTOM SOLUTIONS INC. CN-A01 | User Manual o 3D-Printed Tailbone o Skin-Mimicking Material o 3D-Printed Complete Spine o 3D-Printed Complete Ribcage o 3D-Printed Shoulder (Scapula Bones) o 3D-Printed Pelvis o Realistic Heart with Internal Structures ■ Major Heart Vessels - IVC, SVC, Aorta o Diaphragm o Stomach o Liver with Vessels o Gallbladder o Kidneys with Vessels and Arteries o Spleen with Vessels o Large Intestine o Small Intestine o Caecum o Rectum o Pancreas with Vessels o Bladder o Ureters o Penis o Urethra

 Open the catalog to page 4
User Manual CN-A01-5

TRUE PHANTOM SOLUTIONS INC. CN-A01 | User Manual TRUE PHANTOM SOLUTIONS INC. CN-A01 | User Manual Attenuation Measured at 2.25 MHz [dB/cm] Organs with Organs without 3.1 Thermal Properties of Bone-Mimicking Tissue Thermal Volumetric Specific Thermal Conductivity Heat Capacity Diffusivity Specific Heat

 Open the catalog to page 5
User Manual CN-A01-6

TRUE PHANTOM SOLUTIONS INC. 3.2 HU Values of the Tissue Mimicking Materials Tissue Type Body Tissue Vena Cava 80 (Tissue Part), -1000 (Air Filled Part) Rectum Wall Sigmoid Colon Wall

 Open the catalog to page 6
User Manual CN-A01-7

TRUE PHANTOM SOLUTIONS INC.

 Open the catalog to page 7
User Manual CN-A01-8

TRUE PHANTOM SOLUTIONS INC. CN-A01 | User Manual • The phantom is fabricated based on the anatomy of the real dog. It can be scanned per the standard protocols used while positioning a real dog. • The phantom can be put on horizontal and vertical positions for scanning purposes. • This phantom can be scanned either with or without the ultrasonic gel. To get clearer images, we recommend applying a little gel or using Ultrasound Gel pads to the area before scanning. • To clear the gel off the coated area of the phantom, you can simply wipe off the excess with a soft cloth or tissue once done. •...

 Open the catalog to page 8
User Manual CN-A01-9

TRUE PHANTOM SOLUTIONS INC. CN-A01 | User Manual 10. Storage • When lifting, carrying, or moving the phantom, use caution to avoid damage. • We recommended that two individuals handle the phantom together, ensuring secure and controlled movement. • Hold the phantom firmly by its torso to maintain stability. Avoid any pulling or gripping of the arms, legs, or head. • We suggest the use of a stretcher for carrying the phantom within the premises. • The phantom is made of urethane-based material and should be protected from direct exposure to any intense UV light. • The experiments conducted on...

 Open the catalog to page 9
User Manual CN-A01-10

TRUE PHANTOM SOLUTIONS INC. CN-A01 | User Manual • The phantom is water-resistant and can be cleaned after use. It is ideal for cleaning it either with water or with soapy water. • It is also quite resistant to chemicals, but if stronger solvents are meant to be used with the phantom, we recommend doing a small test on the bottom part of the neck or legs. The chosen solvent can be applied on a small, selected surface of the phantom for a few hours. If there is no visible effect on the phantom's surface, it is safe to assume that the phantom is resistant to the tested chemical and is safe to use...