TRUE PHANTOM SOLUTIONS User ManualAdult Female Torso for X-Ray CT, MRI [CT-A02]
Open the catalog to page 1TRUE PHANTOM SOLUTIONS INC.
Open the catalog to page 2TRUE PHANTOM SOLUTIONS INC. 1. Description The Adult Female Torso Phantom is a groundbreaking innovation in medical imaging simulation, offering an unprecedented level of anatomical accuracy. With the help of AI (Artificial Intelligence) software, this phantoms design has been directly extracted from CT scans of a live, healthy 35-year-old patient with a height of 168cm (5’5″) and a BMI adjusted to 22. As a result, it features highly realistic anatomical structures and organ positioning. Developed in collaboration with medical professionals in the United States and Switzerland, this advanced...
Open the catalog to page 3TRUE PHANTOM SOLUTIONS INC. CT-A02 | User Manual Large and Small Intestines Vaginal Canal Complete Spine Complete Ribcage Shoulders and Clavicles Pelvis Partial Femoral Bones - Body Tissue Mimicking Material - Mammary Gland Tissues Liver
Open the catalog to page 4TRUE PHANTOM SOLUTIONS INC. Front View Side View View Back View Perspective View
Open the catalog to page 5TRUE PHANTOM SOLUTIONS INC. CT-A02 | User Manual ■ The phantom is fabricated based on the anatomy of a real human, and it can be scanned in supine, prone, and lateral positions; more importantly, scanning can be performed from multiple directions. ■ For ultrasound applications, this phantom can be scanned either with or without the ultrasonic gel. To get clearer images, we recommend applying a little gel to the area before scanning. You can simply wipe off the excess with a soft cloth or tissue once done. ■ You can scan the phantom while the pump is running to get imaging results of the breathing...
Open the catalog to page 6TRUE PHANTOM SOLUTIONS INC. CT-A02 | User Manual Type of Tissue Sound Attenuation Measured at 2.25 MHz [dB/cm] Hardness [Shore OO] Organs without Speckles
Open the catalog to page 7TRUE PHANTOM SOLUTIONS INC. CT-A02 | User Manual 10.1 Thermal Properties of Bone-Mimicking Tissue Thermal Volumetric Specific Thermal Conductivity Heat Capacity Diffusivity Specific Heat 10.2 HU Values of the Tissue Mimicking Materials S.No. Tissue Type HU Value (average) Vena Cava 80 (Tissue Part), -1000 (Air Filled Part)
Open the catalog to page 8TRUE PHANTOM SOLUTIONS INC. Mammary Gland Tissues Vaginal Canal Rectum Wall Sigmoid Colon Wall Large and Small Intestines 80 (Tissue Part), -1000 (Air Filled Part)
Open the catalog to page 9TRUE PHANTOM SOLUTIONS INC. CT-A02 | User Manual Soft tissue and organs: Composition of urethane-based soft resin Synthetic bones: Patented ceramic-reinforced epoxy-based composite material Phantom Size: 74 x 35 x 28 cm (29 x 14 x 11 Inches), Weight: 36 kg (80 lbs) (approx.) Shipment Size with Hard Carry Case: 46 x 36 x 17 Inches, Weight: 136 Lbs (approx.) Adult Female Torso Phantom User Manual/Assembly Instructions 2-Year Warranty & Unlimited Customer Service Hard Carry Case
Open the catalog to page 10TRUE PHANTOM SOLUTIONS INC. CT-A02 | User Manual • The phantom is fabricated from the CT scans of a real human body. It can be scanned per the standard protocols used while positioning a real person. • The phantom can be put on horizontal and vertical positions for scanning purposes. • Anterior, Lateral, and Posterior techniques can also be performed. • When moving the phantom to another location, use a stretcher or wheeled table instead of carrying it. • The experiments conducted on the phantom can be performed in a sunny lab, but leaving the phantom under direct sunlight for weeks or months...
Open the catalog to page 11TRUE PHANTOM SOLUTIONS INC. CT-A02 | User Manual • The phantom is made of urethane-based material and should be protected from direct exposure to any intense UV light. • The phantom should be used and stored between 10°C and 63°C (50F- 145.4F) t phantom, we recommend doing a small test on • The phantom should be placed on its belly, and the chosen solvent can be applied on a small, selected surface of the phantom fora few hours. If there is no visible effect on the phantom's surface, it is safe to assume that the phantom is resistant to the tested chemical, and it is safe to use it for the rest...
Open the catalog to page 128 Pages
10 Pages
7 Pages
7 Pages
7 Pages
7 Pages
9 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
9 Pages
8 Pages
10 Pages
8 Pages
9 Pages
8 Pages
10 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
8 Pages
9 Pages
9 Pages
7 Pages
8 Pages
8 Pages
8 Pages
7 Pages
7 Pages
11 Pages
8 Pages
8 Pages
8 Pages
8 Pages
10 Pages
10 Pages
17 Pages
16 Pages
9 Pages
8 Pages
8 Pages
11 Pages
9 Pages
11 Pages
9 Pages
12 Pages
7 Pages
7 Pages
11 Pages
8 Pages
8 Pages
23 Pages
18 Pages
12 Pages
9 Pages
11 Pages
9 Pages
8 Pages
7 Pages
8 Pages
11 Pages
7 Pages
11 Pages
10 Pages
17 Pages
8 Pages
105 Pages
6 Pages
11 Pages
1 Page